M/SS2/E
03

2012

Instruction and Operating Manual
Smart Valve Positioner
SS2L / SS2R Series


 


SS2L / SS2R Series
1. Introduction

2

2. Overview

3

11.5.1 Change of Input Signal

3. Specifications

4

11.5.2 Span Adjustment

4. Part Numbering System (Order Code)



5

11.5.3 Zero Adjustment

5. Principle

6

11.5.4 Selecting DA / RA

6. Descriptions of LCD Display and Buttons

6

11.5.5 Selection of Linear, E.Q.%,

7. Installation

7

of Structure

of Operation

11.5 Sub-Parameters

Flow Diagram

Quick Open, User Set (17points)


7.1 Mounting onto Linear Actuator

11.5.6 Split Range Setting

7.2 Mounting onto Rotary Actuator

11.5.7 Valve Shut-Off Setting

8. Air Connections

14

11.5.8 PID-Gain

8.1 SS2L(linear type)

11.5.8.A P-Gain

8.2 SS2R(rotary type)

11.5.8.B I-Gain

9. Electrical Connections
9.1 Terminal

15

Block


9.2 Measuring

11.5.8.C D-Gain
11.5.9 Setting

Output Signal

of Alarm

Limits

11.5.10 Response Speed Adjustment

9.2.1 With mA Loop Calibrator

11.5.11 Moving Display Figure Position

9.2.2 With Multi-meter

11.5.12 Orifice Control Mode

9.3 Wiring

Alarm

Limits

11.5.13 Setting of Output Signal

9.4 Wiring


SPDT Micro

Switches

11.5.14 Setting of Dead Band

9.5 Setting

SPDT Micro

Switches

11.5.15 Control Mode

10. Quick Auto-Calibration

18

12. Maintenance / Service

10.1 Quick Auto-Calibration

12.1 Preliminary Check Points

10.2 Span Adjustment

12.2 Module Parts

10.3 P-Gain Adjustment


12.3 Structure

10.4 Checking Ambient Temperature

12.3 Re-Setting

11. Description of Parameters Flow

20

11.1 Parameters Flow Diagram

of Gauge Block
of Potentiometer

13. Troubleshooting

40

14. Spare Parts

41

11.2 Main Parameters

14.1 SS2L Spare Parts

11.3 Sub-Parameters


14.2 SS2R Spare Parts

11.4 Setting

14.3 List of Spare Parts

Main

Parameters

11.4.1 LOCK ON / OFF

38

15. Dimensions

11.4.2 Display Mode

15.1 SS2L(linear type)

11.4.3 Manual

15.2 SS2R(rotary type)

Mode

11.4.4 Monitor Mode

15.3 SS2R (with 2 x SPDT micro


44

switch)

11.4.5 Auto-Calibration Mode
11.4.5.A Performing Auto-Calibration
11.4.5.B Initializing Parameters
11.4.6 Self-Test Mode

www.conflow.it

1


SS2L / SS2R Series
1. Introduction
1.1 General Information
This instruction and operating manual contains important notices the user should observe for a personal
safety as well as for prevention against damage to property. Notices concerning a personal safety are
highlighted by a safety alert symbol (

).

1.2 General Safety Instructions
This product was delivered out from the factory without any safety problems after a strict quality
management process. In order to maintain this status and ensure a safe operation of this product,
please be sure to read all safety instructions carefully described in this manual and observe safety
information and symbols without exception.
1.3 Correct Usage



This product can be used only for purposes specified in these instructions. If they are not
definitely stated in these instructions, the user is fully responsible for all changes and retrofits to
this product.



In case of the intrinsically safe product supplied, please make sure to connect this product to the
certified intrinsically safe circuits. These circuits should correspond with the intrinsic safety
parameters indicated on the product nameplate or the certificates. If the circuits do not
correspond with the intrinsic safety parameters on the product nameplate or the certificates, any
safety required for approval can no longer be warranted.



This product is the electrostatic sensitive device that may be seriously damaged by voltages
undetectable to a human. These kinds of voltages occur as soon as a electronic component or
an assembly is touched by a person who is not grounded against a static electricity. Damage to a
electronic component as a result of overvoltage cannot usually be detected immediately. It may
become apparent after a long period of operation. Therefore, please make sure to avoid
electrostatic charge.

1.4 Range and Responsibilities of Personnel


Qualified personnel should be trained, instructed or authorized in operating and maintaining
products and systems according to the safety regulations for electrical circuits, high pressures
and hazardous atmosphere.




For explosion proof products, they should be trained, instructed or authorized in carrying out
work on electrical circuits for hazardous systems.



They should be trained or instructed in maintenance and use of proper safety equipment
according to the safety instructions.



They should have a good experience to identify risks and avoid potential hazards when working
with these products and systems.

1.5 Transport and Storage
Make sure that damages during delivery are prevented through proper packaging.
Products and replacement parts should be returned in their original packaging. If the original packaging
is no longer available, please ensure that they should be packaged to provide sufficient protection
against transport.

www.conflow.it

2


SS2L / SS2R Series
2. Overview of Structure
This product consists of the following parts.
• Electronic card comprised of microprocessor, HART modem and LCD
• Potentiometer for position feedback

• Gauge block

The followings are descriptions of internal parts without cover.

No.
1

LCD

2

Card cover

3

Gauge block

4

Supply air gauge

5

Out 1 gauge

6

UP, Up button

7


DN, Down button

8

MO, Mode button

9

ENT, Enter button

10

Ground

11

12

www.conflow.it

Description

Cable gland
(or blind plug)
Blind plug
(or cable gland)

13


Air venting hole

14

Body

3


SS2L / SS2R Series
3. Specifications
Input signal

4 - 20 mA @ 24 VDC

Min. / Max. current

3.6 mA / 50mA

Voltage drop (impedance)

Without HART

: 8.7 VDC (435Ω @ 20mA)

With HART

: 9.4 VDC (470Ω @ 20mA)

Stroke


Linear type: 8 - 130mm *

Operating Angle

Rotary type: 25 - 120°

Supply air pressure

1.4 - 7.0 bar (20 - 100 psi)

Output pressure range

0 - 100% of supply air

Air flow capacity
Air consumption

80 ℓ/min = 4.8 Nm3/h = 2.8 scfm (Supply = 1.4 bar)
233 ℓ/min = 14 Nm3/h = 8.2 scfm (Supply = 6 bar)
2.8 ℓ/min = 0.17 Nm3/h = 0.1 scfm (Supply = 1.4 ~ 6 bar)

Operating characteristic

Linearity

< ±0.3% F.S

Sensitivity


<

0.2% F.S

Hysteresis

<

0.2% F.S

Repeatability

<

0.2% F.S

LCD display

4-digit

Response speed

1 - 1000 (Min. 1, Max. 1000)

Scan time

2 ms

Shut-off value


0 - 10%

Valve action

Direct acting (DA) / reverse acting (RA)

Operating temperature

-30 ~ +80℃ (-22 ~ +176℉) **

Pneumatic connections

Rc 1/4 or NPT 1/4

Electrical connections

G 1/2, NPT 1/2 or M20 X 1.5

Explosion proof /

Intrinsically safe (Exia IIC T6) / IP66

protection class
Body material / painting

Aluminum diecast / powder coating

Weight

1.6 kg


* For more than 200mm stroke on request
** Operating temperature of -40℃ on request

www.conflow.it

4


SS2L / SS2R Series
4. Part Numbering System (order code)
4.1 Linear type (SS2L)
SS2L
SS2L - TF
SS2L - EX
SS2L - H
SS2L - P

Linear type
Output position transmitter 4-20 mA
2 x alarm micro switches SPDT
ATEX 94/9/CE IECEx Exia IIC T6
HART Communication
PROFIBUS Communication

Other executions on request

SS2R
SS2R - TF
SS2R - EX

SS2R - H
SS2R - P

Rotary type
Output position transmitter 4-20 mA
2 x alarm micro switches SPDT
ATEX 94/9/CE IECEx Exia IIC T6
HART Communication
PROFIBUS Communication

Other executions on request

5. Principle of Operation

If 4-20 mA input signal is supplied, the micro processor compares input signal with position feedback
and sends control signal to the I/P converting module. Pneumatic signal from the I/P converting module
operates the valve and the valve stays at the desired position.

www.conflow.it

5


SS2L / SS2R Series
6. Descriptions of LCD display and Buttons

① Display of input or output
② Main parameters
③ mA, % display mode
④ Operation of HART

⑤ Up button
⑥ Down button
⑦ Mode button
⑧ Enter button

Press "Mode" button for 5 seconds

ㆍ Quick auto-calibration

Press "Up(▲)" button for 5 seconds

ㆍ P-gain adjustment

Press "Down(▼)" button for 5 seconds

ㆍ Span adjustment

Press "Enter" button for 5 seconds

ㆍ Ambient temperature (℃)

① Display of input or output
② Main parameters

ㆍ mA, %
MODE ↔ RUN ↔ DISP ↔ MAN ↔ MON ↔ AUTO
LOCK ↔ TEST ↔ PARM

③ Display mode


ㆍ Selection of mA, % or in reverse way

④ HART communication

ㆍ HART communication

⑤ Up (

ㆍ UP button

)

⑥ Down (

)

⑦ MO (Mode)


ENT(Enter)

ㆍ DOWN button
ㆍ Selection of running mode
ㆍ Selection of parameter group or parameter
ㆍ Save of setting values

www.conflow.it

6



SS2L / SS2R Series
7. Installation
7.1 Mounting onto Linear Actuator
7.1.1 Installation of Follower Guide
UNIWORLD and HYGIENIC Series

PIN LEVER BRACKET

HP60 Series
SCREWS

PIN LEVER BRACKET
7.1.2 Installation of Feedback Lever and Mounting Bracket
Mounting bracket for SS2L positioned is designed to support IEC 60534-6-1.

www.conflow.it

1

Mounting bracket

2

Screws

3

Feedback lever


4

SS2L positioned

5

Feedback pin

7


SS2L / SS2R Series
7.1.3 Mounting onto Cast Yoke or Pillar Yoke
< Cast yoke type >

< Pillar yoke type >

① Cast yoke
② Mounting bracket
③ Screws
④ U-bolts
⑤ Pillar yoke
on request

7.1.4 Mounting onto Other Kind of Cast Yoke

① Cast yoke
② Mounting bracket
③ Screws


www.conflow.it

8


SS2L / SS2R Series
7.1.5. Mounting Diagram

“A” Type

Feedback Levers
30

"A" type: 8 ~ 30mm stroke

“B” Type

"B" type: 8 ~ 70mm stroke standard

65

"C" type: 8 ~ 130mm stroke

“C” Type

"D" type: 80 ~ 200mm stroke

130

7.1.6 Installation of Feedback Pin Follower Guide


www.conflow.it

9


SS2L / SS2R Series
7.1.7 Standard Installation



Supply air directly to the actuator, adjust the air filter regulator and set air when the valve
reaches to 50% stroke.



Install the feedback lever horizontally at 50% stroke position.



If the feedback lever is not installed horizontally, move the mounting bracket up and down little
by little so that it can be positioned horizontally.



Fix the mounting bracket with screws.



Connect air lines between the position and the actuator.




Supply air to the positioned and perform auto-calibration by pushing Mode button for 5
seconds.



The operating angle from 0% to 100% stroke should be within the range of 30°. In case of the
over-range of 30°, move the valve stem pin left and right and make the operating angle stay
within 30°.
① Be sure to install the air filter regulator

before the positioned

and

check a supply air pressure required to move the valve.
② If the operating
range of

-30°

angle of
to

the SS2L positioner

is out


of

the

+30°, MONT is shown on LCD during auto-

calibration. Take action as advised in the above


and

at

12mA

get

the

SS2L feedback

lever

positioned

horizontally

(50%). See

11.4.6. MONT.


www.conflow.it

10


SS2L / SS2R Series
7.2 Mounting onto Rotary Actuator
7.2.1 The SS2R positioned supports NAMUR mounting standard (VDI/VDE 3835, IEC 60534-6-2).

① SS2R positioner

② Multi-size bracket

③ Rotary actuator

ⓐ Assemble the multi-size bracket to the positioner with 4 pcs M6 screw.
ⓑ Mount the positioned onto the actuator with 4 pcs M5 screw.
ⓒ Connect air lines between the positioned and the actuator.
ⓓ Perform auto-calibration by pushing MODE button for 5 seconds.
Be sure to install the air filter regulator AFR80 before the positioned

and

check a supply air pressure required to move the valve.

www.conflow.it

11



SS2L / SS2R Series
7.2.2 Mounting with Fork Lever Type

① SS2R positioner

② Multi-size bracket

③ Rotary actuator

④ Fork lever

⑤ Positioner feedback lever

7.2.3 Position of Fork Lever

Clockwise movement

Counter-clockwise Movement

www.conflow.it

12


B

SS2L / SS2R Series
C


7.2.4 Re-assembling Multi-size Bracket according to Rotary Actuator
L

H

D

E

L
F

(mm)

H

L

(mm)

1

(mm)
2

3

H
(mm)


80

20

130

20

80

30

130

30

80

50

130

50

DRAWN

NAME
Kim. K. W

CHECKED


Ko. S. W

APPROVED

Ko. S. Y

DATE

5

4

TITLE :

POWER- GENEX

ht t p:/ / www.power - genex.com
SIGNATURE
PROJ :
SCALE : 1:2
SIZE

,

QUANTITY

DIMENSION : mm
SHEET 1 OF 1


Check L and H on the actuator and re-assemble the multi-size bracket to fit your actuator
mounting configuration.

www.conflow.it

13

PRODUCT NAME :

3r d
MODEL :

: A3
DWG NO.

AUTOMA A


SS2L / SS2R Series
8. Air Connections
① Be sure to install the air filter regulator before the positioner.
② Supply air should not contain water, oil or moisture.
③ It is recommended to set a supply air pressure 10% higher than the actual operating
pressure of the actuator.

8.1 SS2L (linear type)

8.2 SS2R (rotary type)

www.conflow.it


14


SS2L / SS2R Series
9. Electrical Connections


Be sure to supply the rated voltage and current stated on this manual. Otherwise, it
may cause a serious damage or malfunctions.



Check polarity of + and – exactly and connect wires.



When it is necessary to open the positioner cover at a humid place, more attention is
required. It may cause a serious damage or malfunctions.

9.1 Terminal Block

1
Micro Switch
1, 2+

4-20mA input signal

2


4-20mA input signal

-

3

9

- Alarm limit 2

Ground

11

Switch 1 NO

4

+

4-20mA output signal

12

Switch 1 NC

5

-


4-20mA output signal

13

Switch 1 COM

6

+

Alarm limit 1

14

Switch 2 NO

7

-

Alarm limit 1

15

Switch 2 NC

1

2


3

4

5

6

7

8

9

11

12

13

14

15

16

+

-


F

+

-

+

-

+

-

NO

NC

COM

NO

NC

COM

Input

Alarm limit 1


Ground
Output

Switch 1

Switch 2

Alarm limit 2

www.conflow.it

15


SS2L / SS2R Series
9.2 Measuring Output Signal
Position Transmitter Specifications

9.2.1 With mA loop calibrator

9.2.2 With multi-meter

Output signal

4 – 20mA, 2-wire

Power supply

12 – 30 VDC


Output current limit

30mA DC

Linearity

±0.75% F.S

Operating temperature

-20 ~ +80℃

Zero and span of position feedback (4-20mA output signal) are set automatically during
auto-calibration process.

9.3 Wiring Alarm Limits

24VDC should be supplied for alarm limits.

9.4 Wiring SPDT Micro Switches

Micro Switch Specifications
Type

SPDT

Rating code

10.1A @ 250 VAC


Operating temperature

-25 ~ +85℃

www.conflow.it

16


SS2L / SS2R Series
9.5 Setting SPDT Micro Switches

After auto-calibration process, turn the micro switch cams clockwise slowly and check the contact points.
After checking the contact points of the micro switches at a desired position, fix with screws.
For reference, upper switch 1: No. 11, 12, 13
lower switch 2: No. 14, 15, 16

www.conflow.it

17


SS2L / SS2R Series
10. Quick Auto-Calibration
10.1 Quick Auto-Calibration
Supply 4-20mA input signal and push MODE button for 5 seconds, auto-calibration process will start.
①It

It may take a longer time according to sizes of the control valve and the actuator. Generally, it
will take 2 – 3 minutes with the standard size valve and actuator.




If “DATA” on LCD blinks after auto-calibration process, see the error codes on page 20.
In case of a reverse acting actuator, RA is displayed and a countdown
begins.

RA
5→4→3→2→1→END→RUN (auto-calibration is completed)

DA
In case of a direct acting actuator, DA is displayed and a countdown
begins.

10.2 Span Adjustment (SPAN)
Span is set automatically after auto-calibration process. But it can be re-set manually as below, if
necessary.





Push DN button for 5 seconds, SPAN

Push ENT button, 100 will blink. Push

If SPAN reaches a desired point, push

will appear.


UP or DN button, change the current

MODE button. RUN mode will start.

value and push ENT button for a
memory saving.

The above is just an example to help
understand how to set Span to 98.5%.

Keep pushing UP/DN button, SPAN will increase or decrease fast. 0.1% will increase or
decrease by pushing a button one time.

www.conflow.it

18


SS2L / SS2R Series
10.3 P-Gain Adjustment (P-GN)
Select LOW,

MIDD

or

HIGH in

GROP-Gain after


selecting NORM, SMAL, or

HARD in Control Mode.
If a hunting
SMAL, or

or an oscillation happens after auto-calibration, select a control

HARD) proper

for

again. Change to HIGH from
from

a valve working

condition

and perform

MIDD in GROP in case of a hunting

MIDD in case of an oscillation problem. If a hunting

mode (NORM,
auto-calibration

problem. Change to LOW


or an oscillation still continues to

happen, select other control mode and set in GROP again.



Keep

pushing

U button for

seconds, GROP will appear.
Push ENT.

5



Select HIGH or LOW by pushing UP
or DN button.

If it is necessary to
set PIDGAIN, keep
pushing UP
button
for
5 seconds
and
push

MODE
button when
GROP is
and
shown. PID will
be shown
push ENT to
set PID values

10.4 Checking Ambient Temperature
Keep pushing ENTER button, an ambient temperature
surrounding the positioned will appear. Note that this ambient
temperature appears only while pushing ENTER button.

www.conflow.it

19


SS2L / SS2R Series
11. Description of Parameters Flow
11.1 Parameters Flow Diagram

www.conflow.it

20


SS2L / SS2R Series
11.2 Main Parameters

Ref.

11.4.2
(P. 24)

Parameter

Description

Function

DISP

DISPLAY

changes the LCD display mode

PVPR

PV % value

shows the current position by %

PVMA

PV mA value

shows the current position by mA

PVPR-SVPR


shows the current position by % and mA by turns at

(automatic turn)

intervals of 1 second

SVPR

Input signal % value

shows the input signal by %

SVMA

Input signal mA value

shows the input signal by mA

PV % value

shows the current position by % in a reverse way

(reversed value)

( Ex. PVPR – 10%  PV-R –

Parameter

Description


Function

MAN

MANUAL

operates the valve manually

MSET

MANUAL-SET

operates the valve manually

END

Move to 100%

moves a valve to 100% regardless of input signals

ZERO

Move to 0%

moves a valve to 0% regardless of input signals

STEP

Move by 1%


moves a valve by 1% regardless of input signals

SVPV

PV-R

Ref.

11.4.3
(P. 25)

Ref.

90% )

Parameter

Description

Function

MON

MONITOR

checks the current status of the positioner

11.4.4


CHEK

ERROR CHEK

checks the errors occurred to the positioner

(P. 26)

MILE

Runtime

checks the total valve runtime

PARA

Registry memory values

checks the registry records in memory

Ref.

Parameter

Description

AUTO

AUTO-SET


TUNE

Auto-calibration

performs auto-calibration

REST

RESET

returns to the factory settings

Ref.

Parameter

Description

Function

11.4.6

PARM

Sub-parameters

see the parameters on next page

Ref.


Parameter

Description

Function

TEST

TEST MODE

tests the positioner

TIME

STEP 간 시간

STP1

STEP1

STP2

STEP2

11.4.5
(P. 27)

11.4.7
(P. 27)


STP3

Function
performs auto-calibration

and return to the factory

settings

sets the testing interval time
0% → 50% → 100% → 50% → 0% → Repeat
0% → 25% → 50% → 75% → 100% →
75%
1%→→ 50%
10%→→ 25%
20%→… 0%
90%→→
Repeat
100%

STEP3

→ 90% … 20% → 10% → 0% →
Repeat

www.conflow.it

21



SS2L / SS2R Series
11.3 Parameters
11.3.1 Main Parameters
Ref.

Parameter

Description

Function

Default

11.5.1 (P. 30)

INPU

Input signal

4…20mA or 20…4mA

4…20mA

11.5.2 (P. 30)

R / DA

RA / DA

Reverse acting or direct acting


RA

11.5.3 (P. 30)

L / E.Q /
QOPN/USER

Characteristic

11.5.4 (P. 32)

SPAN

Span adjustment

0…100%

100%

11.5.5 (P. 32)

ZERO

Zero adjustment

0…99%

0%


11.5.6 (P. 33)

PID

11.5.7 (P. 35)

Linear, E.Q. % (1:25 or 1:50),Quick open
or User set (17points)

P-GN / I-GN

Proportional

/ Integral

Linear

Auto-set

/ D-GN

/ Differential gain value

CTRL

SPED / SWST / CNLT

See 11.3.3 CTRL




11.5.8 (P. 36)

DEAD

Dead band

0…9.99%

0.5%

11.5.9 (P. 37)

H/PR

FDGN / HBIS

See 11.3.3 H/PR



11.5.10 (P.
38)

C/MD

NORM / HARD /

Standard actuator, strong valve packing friction,


SMAL

small actuator or angle seat valve

11.5.11 (P.
39)

SUB

Sub-Parameters

See 11.3.4 SUB

NORM


11.3.2 CTRL - Parameters (control speed adjustment)
Ref.

Parameter

Description

Function

Default

(P. 35)

SPED


Response speed

1…1000

1000

11.5.7.B (P. 35)

SWST

Slow start

Smooth operation

Auto-set

11.5.7.C

CNTL

Control limit

50…1250

Auto-set

11.5.7.A

(P. 36)


11.3.3 H/PR - Parameter (only for hard friction mode)
Ref.

Parameter

Description

Function

Default

(P. 37)

FDGN

D-gain setting for hard mode

D-Gain setting for hard mode

Auto-set

11.5.9.B (P. 37)

HBIS

BIOS setting for hard mode

Precise BIOS setting


Auto-set

11.5.9.A

11.3.4 SUB - Parameter
Parameter

Description

Function

Default

11.5.11.A

Ref.
(P. 39)

SHUT

Shut-off

0…9.9%

0.3%

11.5.11.B

(P. 40)


FOPN

Full-open

0…9.9%

0.3%

11.5.11.C

(P. 40)

OUT

4…20mA or 20…4mA

4…20mA

11.5.11.D

(P. 40)

SPLT

Split range

4…12mA or 12…20mA

4…20mA


11.5.11.E

(P. 40)

DIGN

Display place

11.5.11.F

(P. 41)

ALAM

Alarm limit low, high

AL1L/AL1H, AL2L/AL2H

0…10%, 90…105%

11.5.11.G

(P. 43)

ICAL

IN4M / IN20

Factory setting


11.5.11.H

(P. 43)

FCAL

FB4M / FB20

sets the values in accordance with
4~20mA input signals
sets the values in accordance with
4~20mA output signals

Output

signal

Movement to one or two decimal
places

www.conflow.it

1

Factory setting

22


SS2L / SS2R Series

11.4 Setting of Main Parameters
The following

abbreviations will be used hereafter.
MODE

MO

UP

ENTER

ENT

DOWN

UP
DN

11.4.1 LOCK ON / OFF

LOCK

ON

① LOCK ON

OFF

: Saves all setting values.


② LOCK OFF : Be sure to LOCK OFF when it is necessary to read or change the
selected parameters and the saved setting values.
③ Quick auto-calibration, Span, P-Gain can be carried out without

LOCK Off (see “10.

Quick Auto-calibration”)
④ LOCK is on unless any input signal is not supplied.
⑤ It is difficult

to read or change under LOCK ON situation.

11.4.2 Display Mode
DISP

PVPR %

PVMA mA

SVPV %/mA

SVPR %

SVMA mA

PV-R %

Selection of mA, % or in reverse way with values as shown
(Ex. Reverse


: 20% shown → 80% shown)

www.conflow.it

23


Tài liệu bạn tìm kiếm đã sẵn sàng tải về

Tải bản đầy đủ ngay
×