The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte
is absorbed by separators and plates and thus immobilized. Should the battery be
accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the
gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is
completely sealed and is, therefore, maintenance-free, leak proof and usable in any position.
Battery Construction
Component

Positive plate

Negative plate

Container

Cover

Safety valve

Terminal

Separator

Electrolyte

Raw material

Lead dioxide



Lead

ABS

ABS

Rubber

Copper

Fiberglass

Sulfuric acid

Performance Characteristics

General Features














Absorbent Glass Mat (AGM) technology
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
UL-recognized component.
Can be mounted in any orientation.
Computer designed lead, calcium tin alloy
grid for high power density.
Long service life, float or cyclic
applications.
Maintenance-free operation.
Low self discharge.

Dimensions and Weight
Length(mm / inch)
Width(mm / inch)
Height(mm / inch)
Total Height(mm / inch)
Approx. Weight(Kg / lbs)
* Weight deviation: ± 5%

90 / 3.54
70 / 2.76
101 / 3.98
107 / 4.21
1.8 / 3.97


Nominal Voltage
12V
Number of cell
6
Design Life
5 years
Nominal Capacity 77oF(25oC)
20 hour rate (0.25A, 10.5V)
5Ah
10 hour rate (0.47A, 10.5V)
4.7Ah
5 hour rate (0.85A, 10.5V)
4.25Ah
1 hour rate (3.25A, 9.6V)
3.25Ah
Internal Resistance
≤ 42mOhms
Fully Charged battery 77oF(25oC)
Self-Discharge
3% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
-20~60oC
Charge
-10~60oC
Storage
-20~60oC
o
o
75A(5s)

Max. Discharge Current 77 F(25 C)
Short Circuit Current

250A

Charge Methods: Constant Voltage Charge
Cycle use
Maximum charging current
Temperature compensation
Standby use
Temperature compensation

77oF(25oC)
2.40-2.45VPC
2A
-30mV/oC
2.23-2.30VPC
-20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)
End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V

5min 10min 15min 30min
21.0

19.9
18.8
17.6
16.4

12.5
11.9
11.3
10.6
10.0

10.00
9.56
9.10
8.63
8.14

5.50
5.28
5.05
4.81
4.56

1h

3h

5h

10h


20h

3.25
3.13
3.01
2.88
2.74

1.39
1.35
1.30
1.25
1.19

0.92
0.90
0.88
0.85
0.82

0.50
0.49
0.48
0.47
0.46

0.26
0.26
0.25

0.25
0.25

Discharge Constant Power (Watts at 77oF25oC)
End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V

5min 10min 15min 30min 45min

1h

2h

3h

5h

35.0
32.8
30.7
28.5
26.4

6.3
6.1

5.8
5.5
5.2

3.73
3.62
3.50
3.36
3.22

2.63
2.56
2.49
2.42
2.33

1.80
1.77
1.74
1.70
1.66

23.3
22.0
20.6
19.3
17.9

18.2 10.3
17.3 9.7

16.4 9.1
15.4 8.6
14.3 8.1

8.0
7.6
7.3
6.9
6.5

(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.
All data shall be changed without notice,Vision reserves the right to explain
and update the information contained hereinto.

page1 of 2

www.vision-batt.com


13.0

12V5Ah

Constant voltage charging
o
characteristic (0.25CA,25 C)

(%) (XCA) (V)
140


12.0

Voltage(v)

Voltage

O

Discharge characteristic (25 C)

Current

Charged
Volume

CP1250

120

0.25

100

0.20

11.0
10.0

80


9.0

60

8.0

40

0.15

2 3

5
min

20 30

10

60

5
h

2 3

10

20

0

0

20 30

14.0

Charge Voltage

12.0
11.0

0

0 1

Charged Volume

13.0

0.10
0.05

15.0

Charging Current

0


2

4

6

Discharge time

8

10

12

14

16

18

20

Charging time (hours)

Relationship between
charging voltage and temperature

Self-discharge characteristic
110
100


Cycl

15.0

e Us

Capacity(%)

Voltage(V)

15.6

e

14.4
S ta n d

13.8

by Use

90
80
70
60

13.2

o


o

C

o

C

C

50

-10

0

10
20
30
40
Ambient temperature( oC)

50

40

60

0


2

4

6

8
10
12
14
Storage time: months

16

18

20

Cycle service life in relation to
depth of discharge

Life characteristics of Standby use
120

120
100
Capacity(%)

Capacity(%)


100

80

60

Testing conditions:floating voltage:2.27 to 2.30V Cell
ambient temperature: 25 oC(77 oF)

80
60

40

40

20

20

1

0

2
Life(year)

0


3

30% Depth of discharge

100% D.O.D. 50% D.O.D.

200

Temperature effects on float life

400
600
800
1000
Number of cycles(cycles)

1200

1400

Temperature effects on capacity

10

120

Capacity (%)

Life(years)


100

2.30V Cell
1

C
0 .0 5
0 .1 C
C
2
.
0

80
60

1 .0 C
2 .0 C

40

3 .0 C

20
0.1

10

20


30

40

50

0

60

-20

-10

0

10

20

30

40

Temperature( oC)

THE INTERNATIONAL CERTIFICATION NETWORK

ISO9001:2008


MH25860

G4M19906-9202-E-16

www.vision-batt.com

Shenzhen Center Power Tech. Co., Ltd.
Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail:
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2014-1)

Page 2 of 2

50( o C)



×