Fiber Frames
Introduction 106
Fiber Distribution Frames (FDF) 108
Next Generation Frames (NGF) 132
OMX
™
600 Optical Distribution Frames 151
Off-Frame Splicing Solutions 159
www.adc.com • +1-952-938-8080 • 1-800-366-3891
106
6/04 • 1247379
MSO Market Solutions
Fiber Frames
Introduction
ADC’s Fiber Frame Products
• Provide a centralized point for:
- Termination
- Splice
- Jumper storage
- Passive optical components
• Reduce maintenance costs
• Assure increased subscriber retention
• Prevent fiber congestion
• Physical fiber protection
• Widest choice of frame solutions
Fiber Distribution Frames
• Patented individual angled left/right adapters
eliminate 90 degree bends of optical patch cords
• Clear cable routing paths
• Integrated bend radius protection
• Front and rear access or all front access options
• Quick and easy circuit restoration due to superior
patch cord storage options
• Allows integration of advanced optical components
for capacity/service upgrades and local testing
• Dedicated splice bay options available for off-frame splicing:
ADC recommends this option for greater flexibility, more
cost-effective use of office space and reduced time and cost
for installation and maintenance.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
107
6/04 • 1247379
MSO Market Solutions
Next Generation Frame Products
• Unmatched termination density
• Easy access to connectors and patch cords
within a fully loaded frame
• Clear cable routing paths
• Integrated bend radius protection
• Equipment bays for mounting 19" and 23"
equipment within the NGF lineup
• Integrated jumper storage promotes quick and
easy circuit restoration
• Allows integration of advanced optical components
for capacity/service upgrades and local testing
OMX
™
600 Fiber Frame Solution
• 600mm x 300mm footprint
• 10 module mounting positions
• Total front-access frame
• Allows integration of advanced optical
components for capacity/service upgrades
and local testing
• Shipped with lockable front doors
• Dedicated splice bay options available for
off-frame splicing: ADC recommends this
option for greater flexibility, more cost-effective
use of office space and reduced time and cost
for installation and maintenance.
• OMX Interbay Management Panel
- Off-frame jumper slack storage
- Bend radius protection
- 150mm x 300mm
Fiber Frames
Introduction
www.adc.com • +1-952-938-8080 • 1-800-366-3891
108
6/04 • 1247379
MSO Market Solutions
2
7
8
5
6
4
9
3
Main Components of the Front Load FDF
Front Load fiber frames can be ordered and shipped as a single unit. Simply specify the required
components and ADC will assemble the frame for you. Certain items must be ordered as separate line
items and shipped separately for on-site installation; these items are indicated below.
How To Order a Front Load Frame
Select the desired bay based on height.
Select the desired Front Load modules
Connector Modules: Available in 72 position, 96 position and a 12-pack plug-in configuration. The
72 position module is recommended for most applications. Also available in 144 position using ADC’s
LX.5
®
connectors.
Splice Modules: Accommodate splicing for connector modules. (Remember that splice trays and cable
clamps must be ordered separately.)
Storage Modules: Used to store jumpers when 5" bay spacing is not available (storage modules are not
mandatory when the interbay management panel is used).
Value-Added Modules (VAM): 12 position VAM chassis available for Front Load frames. The Front Load
VAM chassis holds up to 12 single VAM plug-ins.
NOTE: Rear Load modules cannot be installed into a Front Load bay.
Metal doors
Upper and lower half bay doors are recommended to protect fibers on the rear side of the bay.
Interbay management panels (ordered and shipped as separate line items)
The interbay management panel mounts between bays in the same manner as a 5" (12.7 cm) bay spacer.
This panel is optional but is recommended for all applications of the frame. An interbay panel should be
mounted on each side of a fiber frame. For underfloor cabling/raised floor applications an underfloor guard
box is required.
Optional Equipment
Rear fiber storage panel (cross-connect applications only)
Provides cable management and service loop storage of fiber optic patch cords which are typically
routed between an ADC fiber distribution frame (FDF) and the fiber optic terminal (FOT) equipment.
Cannot be used on OSP bays where cable clamps are used.
End guards (ordered and shipped as separate line item).
Splice trays
Each splice module will accept up to (16) 12-position single splice trays or (8) 24-position dual splice
trays. Splice trays must be ordered in addition to the splice module.
Pigtail assemblies
Pigtails can be factory loaded into the bay. Once installed they are 100% tested to ensure their
performance in the field.
Blank panels
As necessary for vacant positions.
Cable clamps (ordered and shipped as separate line item)
One cable clamp is required for each cable brought into the frame.
Communication panels
If a communication panel is desired, it will occupy one module location in the bay.
Fiber optic patch cords.
FiberGuide
®
Fiber Management System.
1
Fiber Distribution Frames
Front Load Frames
10
11
12
13
www.adc.com • +1-952-938-8080 • 1-800-366-3891
109
6/04 • 1247379
MSO Market Solutions
Configuration and Order Form
This page may be copied and used to configure a Front Load frame. The configuration drawing may then
be attached to an order.
Front Load frames include front vertical cable
guides and rear fanning triangles. Interbay
management panels and end guards shown
here are ordered separately. Write catalog
numbers for modules in each location on drawing.
*14" lower troughs are recommended for most
applications; however, other lower troughs are
available. Contact ADC’s Technical Assistance
Center at 1-800-366-3891.
1
5
10
15
20
25
30
35
2.00"
7.00'
25.88"
39
4.50"
8
7
6
5
4
3
2
1
14" HORIZ CABLE TROUGH*
5"
2.5"
Bay ________________________ ________
Modules
Metal doors ________________________ ________
Interbay management panel ________________________ ________
Optional Equipment
Rear fiber storage panel ________________________ ________
End guards ________________________ ________
Splice trays ________________________ ________
Pigtail assemblies ________________________ ________
Blank panels ________________________ ________
Cable clamps ________________________ ________
Communication panel ________________________ ________
Fiber optic patch cords
FiberGuide
®
Fiber Management System
Write catalog number in each
location on drawing above
Order on separate form
Order on separate form
Catalog Number Quantity
Special Configuration Instructions
(Example: install modules at factory, location of pigtails in bay, AC outlet, etc.)
Fiber Distribution Frames
Front Load Frames
www.adc.com • +1-952-938-8080 • 1-800-366-3891
110
6/04 • 1247379
MSO Market Solutions
Front Load Fiber Distribution Frame with 14" (35.56 cm) Trough
2.00"
7.00'
1
5
10
15
20
25
30
35
39
4.50"
25.88"
2.5"
5"
8
7
6
5
4
3
2
1
14" HORIZ CABLE TROUGH
(12) CABLE
TIE BRACKETS
(INCLUDED
WITH FDF)
2"
GUARD
BOX
5.00"
5.00"
7' INTERBAY
MANAGEMENT PANEL
E-501-L139 (2)
7' END GUARD
UEGP-7PW (2)
Front Load FDF
E-501-L88
1
5
10
15
20
25
30
35
39
GROUND LUG WITH #6
COPPER WIRE TINNED
(INCLUDED WITH FDF)
.75" REAR
25.88"
FANNING
TRIANGLES
(INCLUDED
WITH FDF)
Recommended Bay Style
Front View*
• Used in cross-connect or interconnect applications when splicing is done within the frame
• Modules attach to front vertical cable guides
• Only ADC Front Load FDF modules can be used in this bay
• Rear Load modules cannot be installed into a Front Load bay
• Up to eight 8" (20.32 cm) modules can be installed in one Front Load bay
• 7' (2.14 m) bay supports up to 1152 terminations
• Front Load FDFs include unequal flange network type (4.5" guard box) rack, 14" lower horizontal
cable trough, front vertical cable guides, rear fanning triangles, ground wire kit and cable tie brackets
Description
Network Style Unequal Flange Front
Load Bay with 14" (35.56 cm) Trough
7' (2.14 m)
9' (2.76 m)
11.5' (3.52 m)
Catalog Number
1
E-501-L88
E-501-L89
E-501-L90
Ordering Information
Dimensions (HxWxD)
7
'
x 26
"
x 12
"
(2.14 m x 66.04 cm x 30.48 cm)
9'
x 26
"
x 12
"
(2.76 m x 66.04 cm x 30.48 cm)
11.5'
x 26
"
x 12
"
(3.52 m x 66.04 cm x 30.48 cm)
Note: Interbay management panels and end guards are ordered separately.
For existing lineups with 8" or 16" lower cable troughs, call ADC Technical Assistance Center 1-800-366-3891.
Side View
Rear View
1
These products are available in black; add “-B” to the end of the catalog number.
Fiber Distribution Frames
Front Load Frames
*Interbay management panels and end guards shown are for reference only. They are ordered separately.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
111
6/04 • 1247379
MSO Market Solutions
Metal Doors
For Use on Front Load Frames Only
Half Bay Metal Doors
The upper and lower half bay doors completely
cover the rear of the bay. Constructed of metal,
these doors are hinged on both sides and latch
securely, protecting fiber from damage and snags.
8" (20.32 cm) Metal Doors
Individual metal doors are available for the rear of
the bay. Six inch doors are designed for the upper
and lower most positions on the bay. Eight inch
doors are designed for the back of the various
modules within the bay. Constructed of metal,
these doors are hinged on both sides and latch
securely to protect fibers on the rear of the bay.
To provide individual doors for the entire bay, two
6" doors and eight 8" doors are needed.
8" metal doors are standard on Rear Load modules.
Order only for Front Load frames.
TOP HALF
DOOR KIT
BOTTOM
HALF
DOOR KIT
39
35
30
25
20
15
10
5
1
DETAIL A
6" DOOR KIT
DOOR ASSY
SEE DETAIL A
8" DOOR KITS
6" DOOR KIT
39
35
30
25
20
15
10
5
1
FRAME
FANNING
TRIANGLE
Description
Half bay metal doors
Mount into Front Load frames or
WECO hole spaced racks only
Upper half bay
Lower half bay
Individual module metal door
Mount into Front Load frames or
WECO hole spaced racks only
6" top or bottom of bay
8" module
Catalog Number
1
E-501-L157
E-501-L156
E-501-L154
E-501-L155
Ordering Information
Dimensions (HxW)
38" x 23" (96.52 x 58.42 cm)
38" x 23" (96.52 x 58.42 cm)
6" x 23" (15.24 x 58.42 cm)
8" x 23" (20.32 x 58.42 cm)
1
These products are available in black; add “-B” to the end of the catalog number.
Fiber Distribution Frames
Front Load Frame Hardware
www.adc.com • +1-952-938-8080 • 1-800-366-3891
112
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Front Load Frame Connector Modules
Connector Module — 72, 96 or 144 Termination
• The patented angle retainer allows removal of the adapter from the front of the module without the
use of tools providing access to the connector on the inside of the panel for cleaning
• Fanning strips maintain 1.5" (3.81 cm) bend radius, provide organization, hold fibers in place at
point of entry to the module
• Removable transparent, smoked plastic cover encloses front of module; protects fibers and
connectors from disturbance
• Designation card, identifying each cable, is visible when cover is opened or closed
• An accessory mounting kit is required when installing a Front Load module into a plain, 23" WECO
drilled, unequal flange rack (Non-ADC Front Load Frame)
• 72 position connector modules are numbered 1-36 on the left, 37-72 on the right. 96 position
connector modules are numbered 1-48 on the left, 49-96 on the right. Standard modules are
numbered vertically (see Figure 1). Horizontally numbered connector modules are also available.
20.40"
8.70"
4.91"
8.00"
20.40"
8.70"
4.91"
8.00"
72 Termination Connector Module
Figure 1
96 Termination Connector Module
Figure 2
Number of
Terminations
72
96
144
Ordering Information
Catalog Number
1
E-501-L13
E-501-AL13
E-501-L145
E-501-AL145
E-501-L14
E-501-AL14
E-501-L6
E-501-AL6
E-501-L14-H1
E-501-AL14-H1
E-501-L6-H1
E-501-AL6-H1
E-501-L519
E-501-L591
Singlemode
Adapter Type
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8° angled polish
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8° angled polish
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8° angled polish
LX.5
®
angled polish
LC ultra polish
Numbered
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
Horizontally
Horizontally
Horizontally
Horizontally
Vertically
Vertically
1
These products are available in black; add “-B” to the end of the catalog number.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
113
6/04 • 1247379
MSO Market Solutions
The pigtails have an overall protective jacket with 12 color-coded 900µm stranded fibers inside. Each
12-fiber pigtail bundle is numbered making it easy to identify each bundle and route them to the desired
splice tray. They are over 5 meters long so they can be routed from any connector module to the splice
module within the frame.
Positions
72
96
144
Ordering Information
Catalog Number
1
FDF-MOD003
FDF-MOD010
FDF-MOD002
FDF-MOD962
FDF-MOD973
FDF-MOD969
FDF-MOD970
E-501-L581
E-501-L591-SP
Singlemode Connector Type
SC ultra polish
SC 8° angled polish
FC ultra polish
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8°angled polish
LX.5
®
angled polish
LC ultra polish
1
6
31
36
37
42
56
72
2
3
4
5
6
1
41
48
8
7
49
89
96
56
Figure 1
Figure 2
Fiber Distribution Frames
Front Load Frame Modules with Pigtails
1
These products are available in black; add “-B” to the end of the catalog number.
Other connector and pigtail assembly types are available. Please contact ADC.
Fiber Pigtail Assemblies
Ordering Information
Catalog Number
FPM-07/0-M006.17M-46
FPM-0E/0-M006.17M-46
FPM-02/0-M006.17M-46
FPM-0D/0-M006.17M-46
FPM-0X/0-M006.17M-46
FPM-0K/0-M006.17M-46
Singlemode Connector Type
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8° angled polish
LX.5
®
angled polish
LC ultra polish
Fiber pigtail assemblies are used within a frame and typically
routed from the backside of a connector module to the splice
module where they are spliced to OSP fibers. ADC offers 5 meter
stranded pigtail assemblies that consist of 12 color-coded 900µm
fibers covered in an overall jacket referred to as a soft wall
bundle. The flexible jacket provides physical protection for the
individual fibers as they are routed from the connector module
to the splice module.
Buffered Fiber
900 micron
PVC Jacket
0.64 mm thick
Soft Wall
(12 Fiber Shown)
www.adc.com • +1-952-938-8080 • 1-800-366-3891
114
6/04 • 1247379
MSO Market Solutions
Front Load Splice Module
Description
Splice module with eight (8) drawers
For Front Load Frames
Cable clamp (0.4" - 1.2" O.D.)
Catalog Number
1
E-501-L33
E-501-L40
Ordering Information
Dimensions (HxWxD)
8.0" x 21.6" x 10.0"
(20.32 x 54.86 x 25.40 cm)
8.00"
21.60"
10.00"
4.94"
Top View
Front Load Splice Module
Loaded with Pigtails
Front Load Splice Module
E-501-L33
• Maximum capacity of 192 splices with stranded fiber, 384 splices with ribbon fiber using ADC’s
new moisture blocking kit for IFC and OSP ribbon fibers.
• Each splice drawer holds two single or one dual splice tray
• Splice trays are available with heat shrink fusion, bare fusion or mechanical (Elastomeric)/mass fusion
• Each drawer designed to handle twenty-four 900 micron pigtails or twelve 3 mm pigtails
• Cover encloses the splice module for protection from normal frame activity
• Pigtail and OSP buffer tubes enter and exit through openings on the back of the module
• Patented slack take-up wheel keeps constant tension on the fiber cable and prevents binding when
drawer is closed
• Cable clamps must be ordered separately and attach to the rear cable management of the frame
Fiber Distribution Frames
Front Load Frame Splice Modules
1
These products are available in black; add “-B” to the end of the catalog number.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
115
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Rear Load Frames
How To Order A Rear Load Frame
When fiber products are ordered with a factory terminated intrafacility fiber cable (IFC), they must be
ordered as individual line items and shipped separately from the bay. Other modules specified can be
assembled with the bay.
Rear Load bays are typically used in cross-connect applications in which splicing is done in the vault or a
designated off-frame splice area.
2
7
8
5
6
4
9
3
Main Components of the Rear Load FDF
Select the desired bay based on height.
Select the desired Rear Load modules
Connector Modules: Available in 72, 96, 144 position and a 12-pack plug-in configuration. These
modules can be ordered loaded with adapters only or with pre-terminated IFC. The 72 position module
is recommended for most applications. Connector modules with IFC can be ordered with IFC oriented
for underfloor routing
Storage Modules: Used to store jumpers when 5" bay spacing is not available (storage modules are not
mandatory when the interbay management panel is used).
Value-Added Modules (VAM): 12 position VAMs are available for Rear Load style frames and house
VAM plug-ins. The Rear Load style VAM chassis holds up to 12 single VAM plug-ins.
All Rear Load style modules come standard with 8" (20.32 cm) rear doors and rear cable management
attached at the factory.
NOTE: For applications in which splicing will be done in the FDF, Front Load frames are recommended
Interbay management panels (ordered and shipped as separate line items)
The interbay management panel mounts between bays in the same manner as a 5" (12.7 cm) bay spacer.
This panel is optional but is recommended for all applications of the frame. An interbay panel should
be mounted on each side of a fiber frame. For underfloor cabling/raised floor applications, an underfloor
guard box is required.
Optional Equipment
End guards (ordered and shipped as separate line item).
Blank panels
As necessary for unused positions.
Cable clamps (ordered and shipped as separate line item)
One cable clamp is required for each multifiber cable brought into the bay. Rear Load connector
modules with IFC include a cable clamp.
Communication panels
If a communication panel is desired, it will occupy one module location in the bay.
Fiber optic patch cords.
FiberGuide
®
Fiber Management System.
1
www.adc.com • +1-952-938-8080 • 1-800-366-3891
116
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Rear Load Frames
Configuration and Order Form
This page may be copied and used to configure a Rear Load frame. The configuration drawing may then be
attached to an order.
Interbay management panels and end guards
shown here are ordered and shipped separately.
Write the catalog numbers for the modules in
each location on the drawing.
Pre-terminated Rear Load modules are shipped
separately from the bay.
14" lower troughs are recommended for most
applications; however, other lower troughs
are available.
1
5
10
15
20
25
30
35
2.00"
7.00'
25.88"
39
4.50"
8
7
6
5
4
3
2
1
14" HORIZ CABLE TROUGH*
5"
2.5"
Bay _____________________ ________
Modules
Interbay management panel _____________________ ________
Optional Equipment
End guards _____________________ ________
Blank panel _____________________ ________
Cable clamps _____________________ ________
Communication panel _____________________ ________
Fiber optic patch cords
FiberGuide
®
Fiber Management System
Write catalog number in each
location on drawing above
Order on separate form
Order on separate form
Catalog Number Quantity
Special Configuration Instructions
(Example: AC outlet)
www.adc.com • +1-952-938-8080 • 1-800-366-3891
117
6/04 • 1247379
MSO Market Solutions
Rear Load Fiber Distribution Frame with 14" (35.56 cm) Trough
2.00"
5.0" 5.0"
7.00'
1
5
10
15
20
25
30
35
39
4.50"
8
7
6
5
4
3
2
1
14" HORIZ CABLE TROUGH
(12) CABLE
TIE BRACKETS
(INCLUDED
WITH FDF)
2"
GUARD
BOX
5.00"
5.00"
7' INTERBAY
MANAGEMENT PANEL
E-501-L139 (2)
7' END GUARD
UEGP-7PW (2)
REAR LOAD FDF E-501-L91
1
5
10
15
20
25
30
35
39
GROUND LUG WITH #6
COPPER WIRE TINNED
(INCLUDED WITH FDF)
.75" REAR
25.88"25.88"
2.5"
Recommended Bay Style
Front View* Side View Rear View*
*Interbay management panels and end guards shown are for reference only. They are ordered separately.
• Rear Load bays are recommended for applications when splicing is done in the vault or at an
off-frame splice area
• Up to eight 8" (20.31 cm) modules can be installed in one Rear Load bay
• 7' (2.14 m) bay supports up to 1152 terminations
• Rear Load FDFs include unequal flange network type (4.5" guard box) rack, 14" lower horizontal
cable trough, front vertical cable guides, ground wire kit and cable tie brackets
• All Rear Load modules are equipped with rear fanning triangles and 8" (20.32 cm) rear doors
Description
Network Style Unequal Flange Rear
Load Bay with 14" (35.56 cm) Trough
7' (2.14 m)
9' (2.76 m)
11.5' (3.51 m)
Catalog Number
1
E-501-L91
E-501-L92
E-501-L93
Ordering Information
Dimensions (HxWxD)
7
' x 26" x 12"
(2.14 m x 66.04 cm x 30.48 cm)
9
' x 26" x 12"
(2.76 m x 66.04 cm x 30.48 cm)
11.5
' x 26" x 12"
(3.52 m x 66.04 cm x 30.48 cm)
For existing lineups with 6", 8" or 16" lower cable troughs, call ADC Technical Assistance Center,
1-800-366-3891.
Fiber Distribution Frames
Rear Load Frames
1
These products are available in black; add “-B” to the end of the catalog number.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
118
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Rear Load Frame Connector Modules
Connector Module — 72 or 96 Termination
• All Rear Load modules come with rear doors and cable management attached
• Patented angled retainers designed for easy removal without use of tool; allows easy access to back
of the adapter/receptacle from front of bay
• Fanning strips maintain 1.5" (3.81 cm) bend radius, provide organization, hold fibers in place at
point of entry to the module
• Removable transparent, smoked plastic cover encloses front of module; protects fibers and connectors
from disturbance
• An accessory mounting kit is required when installing a Rear Load module into a plain, 23" WECO
drilled, unequal flange rack (Non-ADC Front Load Frame)
72 Connector Module for Rear Load Frames
96 Connector Module for Rear Load Frames
24.41"
12.00"
8.00"
24.41"
12.00"
8.00"
8.00"
24.40"
Front View
Duplex Connector Module
1
These products are available in black; add “-B” to the end of the catalog number.
Number of
Terminations
72
96
144
Ordering Information
Catalog Number
1
FCM-670000
FCM-6L0000
FCM-620000
FCM-6Q0000
FCM-DA/J0000
FCM-770000
FCM-7L0000
FCM-720000
FCM-7Q0000
FCM-TY0000
FCM-TK0000
Singlemode
Adapter Type
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8° angled polish
36 SC Duplex
SC ultra polish
SC 8° angled polish
FC ultra polish
FC 8° angled polish
LX.5
®
angled polish
LC ultra polish
Numbered
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
Vertically
www.adc.com • +1-952-938-8080 • 1-800-366-3891
119
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Rear Load Frame Connector Modules
Connector Module Equipped with Singlemode IFC
• Modules with IFC attached ship as a single unit with cable clamp installed
• Modules completely loaded with adapters, even when partially loaded
with IFC
• Two ordering options:
- Standard spool: module mounted to rack before IFC is uncoiled
- Modified spool: module attached to spool and rotated as the IFC is
uncoiled from the spool. The modified spool works best when a pipe
is slid through the middle of the spool for use as an unwinding feature
Catalog Number
FCM- __ __ / __ __ __ __ __ - __
Module Type Spool Type
6 72 position FDF module standard spool
7 96 position FDF module standard spool
8 72 position FDF module modified spool
9 96 position FDF module modified spool
D 36 position/duplex standard spool
E 36 position/duplex modified spool
T 144 position FDF module (LX.5
®
) standard spool
W 144 position FDF module (LX.5
®
) modified spool
Singlemode
Adapter/Connector Type
0 Stub end
7 SC, bronze sleeve
L SC angled polish, zirconia sleeve
2 FC, bronze sleeve
Q FC angled polish, zirconia sleeve
Y LX.5
®
angled polish, zirconia sleeve
K LC ultra polish
* Modules using ADC’s house cable have a shorter
lead time than modules using a specific cable
manufacture. ADC only provides GR-409
compliant cable that meets or exceeds our high
quality standards. House cable vendors include
Alcatel, Corning, and Pirelli.
When selecting ADC’s house cable, the module
type must be either 8, 9 or E. The module will
then be packaged in ADC’s new protected spool
where the module is shipped inside the spool for
added protection.
Cable Type
ZB 72 IFC stranded House Cable*
ZC 96 IFC stranded House Cable*
Special Configurations
Putty, cable exits up
B Black, cable exits up
D Putty, cable exits downward for
raised floor installation
BD Black, cable exits downward for
raised floor installation
Length in Meters
+
+
+
A 1x12 IFC stranded fiber SMF-28
B 1x24 IFC stranded fiber SMF-28
HA 1x24 IFC ribbon fiber Sumitomo
2 1x48 IFC stranded fiber SMF-28
JA 1x48 IFC ribbon fiber Sumitomo
V 1x72 IFC stranded fiber SMF-28
DS 1x72 IFC ribbon fiber Sumitomo
L 1x96 IFC stranded fiber SMF-28
LA 1x96 IFC ribbon fiber Sumitomo
EH 1x144 IFC stranded fiber SMF-28
LH 1x144 IFC ribbon fiber Sumitomo
Other connector and cable types are available. Please contact ADC.
leave
blank
www.adc.com • +1-952-938-8080 • 1-800-366-3891
120
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Rear Load Frame Splice Modules
Rear Load Splice Module
8.00"
21.60"
12.00"
Rear Load Splice Module
E-501-L18
Top View
Rear Load Splice Module
Loaded with Pigtails
• Both outside plant (OSP) and fiber optic terminal (FOT) patch cords are terminated at the rear of the
FDF, making them less vulnerable during routine maintenance performed on the front of the FDF.
• Each splice drawer holds two 12 fiber (single) or one 24 fiber (dual) splice tray
• Splice trays are available with hear shrink fusion, bare fusion or mechanical (Elastomeric)/mass fusion
• Each drawer designed to handle twenty-four 900 micron pigtails or twelve 3 mm pigtails
• Cover encloses the splice module for protection from normal frame activity
• Pigtail and OSP buffer tubes enter and exit through openings on the back of the module
• Patented splice tray with slack take-up wheel keeps constant tension on the fiber cable, prevents
binding when drawer is closed
• Cable clamps must be ordered separately
Description
Splice module with either (8) drawers
For Rear Load frames
Cable clamp (0.4" - 1.2" O.D.)
Catalog Number
1
E-501-L18
E-501-L40
Ordering Information
Dimensions (HxWxD)
8.0" x 24.41" x 12.0"
(20.32 x 62.0 x 30.48 cm)
1
These products are available in black; add “-B” to the end of the catalog number.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
121
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Front and Rear Load Frame Accessories
Splice Trays
Single and Dual Splice Trays
Description
12 Position Splice Trays
Single Height
Bare fusion
Heat shrink fusion
Mechanical (elastomeric)
18 Position Splice Trays
Single Height
Heat shrink fusion
24 Position Splice Trays
Dual Height
Bare fusion
Heat shrink fusion
Mechanical (elastomeric)
Mass Fusion
Splice Module
Capacity
192
192
192
192
192
192
192
Number of Splice
Trays per Drawer
2
2
2
2
1
1
1
Number of
Splices per Tray
12
12
12
18*
24
24
24
Catalog Number
FST-FT
FST-HS
FST-MT
FST-HS-3
FST-D-FT
FST-D-HS
FST-D-MT
Ordering Information
* Used with 8 fiber soft-wall bundled pigtail assembly, maximum 32 fibers per drawer
Other splice types are available. Please contact ADC.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
122
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Front and Rear Load Frame Hardware
Rack Installation Kits
FRONT OF
FRAME
REF
FRONT OF
FRAME
REF
1.81" (2)
4.81"
(3)
7.82" (2)
4.31" (4)
5.16" (2)
4.0" X 8.0" SLOT RACK 23"
RACK (SHOWN) 4.0"
DIA FOR 19" RACK
1.0" X 2.76"
SLOT (4)
1.63" X 3.16"
SLOT (2)
2.0"
5.19"
2.69"
4.38"
5.25" 5.25"
5/8"-11 WELD NUT (3)
OPPOSITE SIDE
5.38"
2.69"
3.0" 3.0"
5/8"-11 WELD NUT (3)
OPPOSITE SIDE
7' TOP
MOUNTING DETAIL
8', 9' & 11'6" TOP
MOUNTING DETAIL
0.78 (2) ON 23"
RACKS ONLY
BOTTOM VIEW
BASE MOUNTING DETAIL
7', 8', 9', 11'6"
25.875"
0.495" HALF SHEAR
FORM TO NEAR SIDE 4X
(KNOCKOUT)
TOP VIEW
BASE MOUNTING DETAIL
7', 8', 9', 11'6"
9.625"
TOP ANGLE IRON
2 X 2
2" GUARD BOX
HAS BEEN REMOVED
FOR CLARITY
45° (4)
3.0" 3.0"
Network Type Unequal Flange Rack Mounting Details
Relay Rack Base
Relay Rack
Raised Floor
Concrete Floor
Concrete Floor
Anchor Detail
1
Wedge (4)
with Anchor Kit
Washer (4)
with Anchor Kit
Hex nut, Torque (4)
with Anchor Kit
Stud (4) with
Anchor Kit
Underfloor Mounting Kit
www.adc.com • +1-952-938-8080 • 1-800-366-3891
123
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Front and Rear Load Frame Hardware
Rack Installation Kits
Description
Rack installation kit for 7' racks, includes:
- (1) floor mounting kit
- (1) top attachment kit for 7' racks
- (12) rack tie brackets kits
- (1) rack ground kit for 7' racks
Rack installation kit for 9' and 11' 6" racks, includes:
- (1) floor mounting kit
- (1) top attachment kit for 9' and 11' 6" racks
- (22) rack tie brackets kits
- (1) rack ground kit for 9' and 11' 6" racks
Universal anchor kit, for all UEF Racks includes:
- (4) anchor assemblies
- (2) universal hold down bars
- (8) anchor plate washers
- (8) shim plates .063
- (4) shim plates .125
5/8" Raised Floor Mounting Kit
- (4) threaded rods 5/8" - 11"x 12"
- (12) heavy nuts, locks and flat washers
- (4) nuts with springs 1/2"x 13", and shoulder washers
- (1) 10' unistrut and anchor kit
5/8" Raised Floor Mounting Kit
- (4) threaded rods 5/8" - 11"x 30"
- (12) heavy nuts, locks and flat washers
- (4) nuts with springs 5/8"x 11", and shoulder washers
- (1) 10' unistrut
- (1) RINST-FLR universal anchor kit
1/2" Raised Floor Mounting Kit, 30" Threaded Rod
- (4) threaded rods 1/2" - 13" x 30"
- (12) heavy nuts, locks and flat washers
- (4) nuts with springs 1/2"x13", and shoulder washers
- (1) 10' unistrut and anchor kit
1/2" Raised Floor Mounting Kit, 42" Threaded Rod
- (4) threaded rods 1/2" - 13" x 42"
- (12) heavy nuts, locks and flat washers
- (4) nuts with springs 1/2"x 13", and shoulder washers
- (1) 10' unistrut and anchor kit
Catalog Number
RINST-DSX7-PW
RINST-DSX9-PW
RINST-FLR
FDF-ACC146
FDF-ACC238
FDF-ACC136
FDF-ACC198
Ordering Information
Rack installation kits may be used on network racks and are rated to Earthquake Zone 4 areas.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
124
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Front and Rear Load Frame Hardware
Interbay Management Panel
Description
Universal interbay management panel
Includes trough filler insert and lower
5" (12.7 cm) guard box
Use with 14" [35.56 cm] trough only
7' H (2.14 m)
9' H (2.75 m)
11.5' H (3.51 m)
Optional covers for interbay
management panels
7' H x 5" W (2.14 m x 12.7 cm)
Catalog Number
1
E-501-L139
E-501-L142
E-501-L143
E-501-L409
Ordering Information
Dimensions (HxWxD)
7' x 5
" x 12"
(2.14 m x 12.7 cm x 30.48 cm)
9' x 5
" x 12"
(2.76 m x 12.7 cm x 30.48 cm)
11.5' x 5
" x 12"
(3.52 m x 12.7 cm x 30.48 cm)
• Provides storage between the bay
for patch cords
• Available for 7', 9' or 11.5' (2.14,
2.75, 3.51 m) bays
• 5" trough filler insert protects the
fiber in the lower trough between bays
• Includes a lower guard box and 5"
trough filler insert
• To provide space for these panels,
all bays must be spaced 5"
(12.7 cm) apart
See following page for information on
underfloor guard boxes.
Optional retrofit cover kits are available for 14" lower troughs.
For existing lineups with 6", 8" or 16" lower cable troughs, call ADC Technical Assistance Center, 1-800-366-3891.
1
These products are available in black; add “-B” to the end of the catalog number.
www.adc.com • +1-952-938-8080 • 1-800-366-3891
125
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Front and Rear Load Frame Hardware
1
These products are available in black; add “-B” to the end of the catalog number.
Guard Boxes – Underfloor
Description
Underfloor guard boxes
Rear access only. Used for routing OSP
or IFC cable or patch cords from under
floor to the rear of the bay.
Front and rear access. Used for routing
OSP, IFC or patch cords from under floor
to the rear of the bay and patch cords
from under floor to the front of the bay.
Catalog Number
1
FDF-ACC139
FDF-ACC152
Ordering Information
Dimensions (HxWxD)
3.94" x 4.88" x 4.9"
(10 x 12.4 x 12.45 cm)
7.05" x 8.6" x 5"
(17.9 x 21.84 x 12.7 cm)
4.88"
3.94"
4.90"
5.00"
3.88"
1.00"
8.60"
3.08"
3.17"
FDF-ACC139
Rear Access Underfloor
Guard Box (Front View)
FDF-ACC152
Shown Installed Between Network Racks
and at end of lineup (Front View)
FDF-ACC152
Front/Rear Access Underfloor
Guard Box (Rear View)
www.adc.com • +1-952-938-8080 • 1-800-366-3891
126
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Front and Rear Load Frame Hardware
1
These products are available in black; add “-B” to the end of the
catalog number.
Rear Fiber Storage Panel
Description
Rear fiber distribution frame storage panel kit
Includes one storage panel, with spools and
mounting hardware
Catalog Number
1
FDF-RFSP
Ordering Information
• Provides cable management and service loop storage of fiber optic
patch cords typically routed between an ADC fiber distribution
frame (FDF) and the fiber optic terminal (FOT) equipment
• Kit contains one storage panel with spools and mounting
hardware to secure the panel to the frame
• Can be installed in existing lineups
• Mounts on either left or right duct area of FDF
• Attaches to 7', 9' or 11.5' frames
• ADC recommends storing excess patch cord slack at the FOT to
distribute the slack to multiple locations throughout the central
office/headend.
• Cannot be mounted onto the frame if any cable clamps are
present on that side of the frame
End Guards
• Attaches to either a bay or interbay management panel
• Serves as a mounting place for outlets and switches
• Used interchangeably for either left or right applications
• Provides protection and a finished appearance at the start
and end of bay lineups
12"
D
2.5" W
H
Description
Network bay end guard panel
Mounts on IMP or bay
2.5" W (6.35 cm) and:
7' H (2.14 m) x 12" D
9' H (2.75 m) x 12" D
11.5' H (3.51 m) x 12" D
Catalog Number
1
UEGP-7PW
UEGP-9PW
UEGP-115PW
Ordering Information
www.adc.com • +1-952-938-8080 • 1-800-366-3891
127
6/04 • 1247379
MSO Market Solutions
1
These products are available in black; add “-B” to the end of
the catalog number.
Fiber Distribution Frames
Accessories
Horizontal Cable Troughs
Lower horizontal cable troughs are always
included with fiber bays. They can be
purchased separately for special applications.
The upper cable trough is not a standard part
of the bay. It should be used in applications in
which patch cords need to be brought from the
front of the frame to the rear. The upper cable
trough is putty white and mounts at the top of
the bay. Bend radius limiters are provided on
the edges of the trough to maintain minimum
bend radius requirements.
14" Lower Cable Trough
E-501-L136
4" Upper Cable Trough
E-501-L164
6" Lower Cable Trough
E-501-L73
Description
Lower horizontal cable trough
23" W x 5" D (58.42 x 12.7 cm)
6" (15.24 cm) Height
8" (20.32 cm) Height
14" (33.56 cm) Height
16" (40.64 cm) Height
Upper horizontal cable trough with pass
through capability
4" H x 23" W x 10" D
(10.16 x 58.42 x 12.7 cm)
Catalog Number
1
E-501-L73
FDF-ACC-LHCT
E-501-L136
FDF-ACC-LDCT
E-501-L514
Ordering Information
Description
Cover for 14" (33.56 cm) lower horizontal
cable trough; requires modified lower
horizontal cable troughs
for 8" x 23" (20.32 x 58.42 cm)
mounting systems
Catalog Number
1
FDF-ACC167
Ordering Information
Cover Kit For Lower Horizontal Cable Troughs
FRONT
TROUGH COVER
14" UNIVERSAL
TROUGH
FILLER TROUGH
FRAME
INTERBAY
MANAGEMENT
PANEL
(Optional cover
for interbay
manage-
ment panel.
See page 16
for ordering
information)
www.adc.com • +1-952-938-8080 • 1-800-366-3891
128
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Accessories
Grounding Kit
The fiber distribution frame is equipped with a grounding kit designed with mechanical (clamps,
straps, connectors) fittings. Order this kit only if you are building a frame using your own rack. When
connecting frame ground to office ground conductor, an H-TAP bonding kit should also be ordered.
Grounding Kit Accessories
12.24" X 1/2"
Screw
Wire Clip
2 Hole Lug
12.24" x 1/2" Screw
Copper Wire Tinned
Central Office
Ground
GAK Bracket
Crimp Lug
Split bolt connector
(included with E-501-L40
Cable Clamp Kit)
H-Tap
6 AWG
Stranded Wire
6 AWG
Solid Wire
Fiber Frame
(Rear)
Wire Clip Mounting
Description
FDF grounding wire kit*
H-TAP bonding kit
Grounding kit, channel racks
Catalog Number
E-501-L37
E-501-L166
GAK
Ordering Information
* Included with ADC Fiber Frame
Each kit includes the following:
FDF ground wire kit (included with all frames)
2 hole terminal lug 1 each
#6 copper tinned wire 13'
Wire clips 8 each
12 - 24 x 1/2" screws 10 each
H-TAP bonding kit
HTAP 1 each
HTAP insulated cover 1 each
2 hole terminal lug, crimp 3 each
Terminal lug, screw 4 each
Wire, 6 AWG stranded insulated 2'
Washer, star 6 each
Grease, no-ox 1 tube
GAK grounding kit
Bracket 1 each
Clamping bolt 2 each
Nut 2 each
Screw 10 each
Wire Clip 8 each
Wire, 6 AWG solid copper tinned 13'
www.adc.com • +1-952-938-8080 • 1-800-366-3891
129
6/04 • 1247379
MSO Market Solutions
Fiber Distribution Frames
Accessories
Rack Filler Plates
Rack filler plates are recommended for use between
the splice frame and adjacent bays or end guards.
The rack filler plates are putty white and come with
a guard box.
Description
Rack filler plates, putty white, with guard box
(5" W x 12" D [12.7 x 30.48 cm])
7' H (2.14 m)
9' H (2.75 m)
11.5' H (3.51 m)
Catalog Number
1
7RFP-5NPW
9RFP-5NPW
115RFP-5NPW
Ordering Information
5"
(WIDTH)
12"
(DEPTH)
7'
(HEIGHT)
AC Outlet Kit and Raceways
End View
Cap Fitted
BK
W
GN
Hole for
AC Supply
Access
Prewired 3-Wire
Duplex Receptacle
IG Series (2 Pls.)
Base MTG Hole
25.84"
1.28"
.75"
AC Outlet Kit
The AC outlet kit provides the hardware for mounting AC power outlets on the frame. Each kit includes a
prewired AC power outlet strip that mounts at the bottom of the frame. Raceways for routing the power
wires to the outlet strip are also available.
Description
AC outlet kit – 25.84" (65.63 cm)
AC raceway
25.84" (65.63 cm) – used for bays which do not require AC power
5.0" (12.7 cm) – used with AC outlet kit when bays are spaced 5.0" (12.7 cm)
Catalog Number
1
ACOK-PWNB
ACB-PWNB
AC-PWNB-RS5*
Ordering Information
* This raceway must be ordered with each Interbay Management Panel when an AC outlet is ordered.
1
These products are available in black; add “-B” to the end of the catalog number.