CGT12-120X

12V 120Ah(10hr)

Gel battery shows some distinctive advantages over flooded battery or AGM battery,
such as super thermal stability, high deep discharge capability, good recovery from
deep discharge , even if the battery is left discharged for three days, it will recover
to 100% of capacity. With the above-mentioned advantages, the gel battery has
long service life, specially suitable for motive power applications, such as golf trailer,
sruubber, folklift,etc.The deep discharge cycles increased 50% as compared with
the AGM battery.
Battery Construction
Component

Positive plate

Negative plate

Container

Cover

Safety valve

Terminal

Raw material

Lead dioxide

Lead



ABS

ABS

Rubber

Copper

General Features
● Nanometer SiO 2 and H 2 SO 4 gelled
electrolyte technology for efficiency
gas recombination of up to 99% and
freedom from electrolyte maintenance
or water adding.
● Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
● Can be mounted in any orientation.
● Computer designed lead, calcium tin alloy
grid for high power density.
● Long service life, float or cyclic
applications.
● Maintenance-free operation.
● Low self discharge.
● Case and cover avaiable in both standard
and flame restardant ABS.
Dimensions and Weight
Length(mm / inch)
Width(mm / inch)
Height(mm / inch)

Total Height(mm / inch)
Approx. Weight(Kg / lbs)

* Weight deviation: ± 3%
110±2

2

288±2
295±2
F12

Electrolyte
Gelled acid

Performance Characteristics
Nominal Voltage
12V
Number of cell
6
Design Life
12 years
Nominal Capacity 77oF(25oC)
10 hour rate (12.0A, 10.8V)
120Ah
5 hour rate (21.4A, 10.5V)
107Ah
1 hour rate (87.9A, 9.6V)
87.9Ah
Internal Resistance

5.0mOhms
Fully Charged battery 77oF(25oC)
Self-Discharge
2% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
-20~60oC
Charge
-10~60oC
Storage
-20~60oC
850A(5s)
Max. Discharge Current 77oF(25oC)

Discharge Constant Current (Amperes at 77oF25oC)

End point
10min 15min
volts/cell
1.60V
243
198
1.65V
227
187
1.70V
212
177
1.75V
196

166
1.80V
180
155

M8
Ø16

PVC

Charge Methods: Constant Voltage Charge 77oF(25oC)
2.40-2.45VPC
Cycle use Charge Voltage:
Maximum charging current
36A
-30mV/ oC
Temperature compensation
2.20-2.30VPC
Standby use
-20mV/ oC
Temperature compensation

552 / 21.7
110 / 4.33
288 / 11.3
295 / 11.6
44.5 / 98.2

552±2


Separator

30min

1h

3h

5h

10h

135
129
124
119
113

87.9
85.5
83.1
80.7
78.3

36.2
35.6
34.7
33.8
32.9


22.7
22.3
21.8
21.4
20.9

12.3
12.3
12.2
12.1
12.0

Discharge Constant Power (Watts per cell at 77oF25oC)

End point
10min 15min
volts/cell
1.60V
427
360
1.65V
401
341
1.70V
374
322
1.75V
349
303
1.80V

321
284

30min

1h

3h

5h

10h

247
238
230
220
210

165
161
157
152
148

68.7
67.4
66.1
64.6
63.3


43.6
43.0
42.3
41.7
41.0

24.7
24.4
24.0
23.8
23.3

(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.
All data shall be changed without notice,Vision reserves the right to explain
and update the information contained hereinto.

page1 of 2

www.vision-batt.com


CGT12-120X

Charging characteristic for Cycle use

O

Discharge characteristic (25 C)


0

1

2

3

60

3

2

5

10

2.40

100

0.14

2.20

80
60
40


1.60

0.05

1.40

h

0

8

12

16

20

110

Capacity(%)

100
90

15.6

10.4


7.8

5.2

2.6

15.0

10.0

7.5

5.0

2.5

14.4

9.6

7.2

4.8

2.4

13.8

9.2


6.9

4.6

2.3

60

13.2

8.8

6.6

4.4

2.2

50

-10

0

10

20

30


40

50

80
70

40

60

Ambient temperature( oC)

0

3

6

9

12
15
18
21
Storage time: months

24

Cycle service life in relation to

depth of discharge

Life characteristics of standby use

Capacity(%)

100
80
60

Testing conditions: floating voltage: 2.27 to 2.30V/Cell
ambient temperature: 25oC(77 oF)

40
20
0

0

2

4

6
Life(year)

8

10


12
Number of cycles(cycles)

Temperature effects on float life

Temperature effects on capacity

2.27V/Cell

10

Capacity (%)

Life(years)

15

5

0

10

24

Self-discharge characteristic

(V/CELL)

(V/6V)


(V/4V)

(V/8V)

4

Charging time (hours)

Relationship between
charging voltage and temperature
(V/12V)

100%(0.1CAx10H)
---- 50%(0.1CAx5H)
Charge
Charge Voltage(2.45V/Cell)
Charge Current 0.1CA
o
Temperature25 C

1.80

0.08

Discharge time

120

Discharge


2.00

0.11

0.02

20

20

)Ratio

Voltage(V)/PerCell

120A 87.9A

20 30

5
10
min

0.17

ChargeCurrent(CA)

12A
33.8A 21.4A
240A


120

Charged Volume(%)

Battery voltage(V)

12.0

9.6

12V 120Ah

20

30

40

50

Temperature( o C)

THE INTERNATIONAL CERTIFICATION NETWORK

ISO9001:2008

MH25860

G4M19906-9202-E-16


www.vision-batt.com

Shenzhen Center Power Tech. Co., Ltd.
Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail:
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2014-1)

Page 2 of 2

27

30



×