CG2-400

2V 400Ah(10hr)

Gel battery shows some distinctive advantages over flooded battery or AGM battery,
such as super thermal stability, high deep discharge capability, good recovery from
deep discharge , even if the battery is left discharged for three days, it will recover
to 100% of capacity. With the above-mentioned advantages, the gel battery has
long service life, specially suitable for motive power applications, such as golf trailer,
sruubber, folklift,etc.The deep discharge cycles increased 50% as compared with
the AGM battery.
Battery Construction
Component

Positive plate

Negative plate

Container

Cover

Safety valve

Terminal

Raw material

Lead dioxide

Lead



ABS

ABS

Rubber

Copper

General Features
● Nanometer SiO 2 and H 2 SO 4 gelled
electrolyte technology for efficiency
gas recombination of up to 99% and
freedom from electrolyte maintenance
or water adding.
● Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
● UL-recognized component.
● Can be mounted in any orientation.
● Computer designed lead, calcium tin alloy
grid for high power density.
● Long service life, float or cyclic
applications.
● Maintenance-free operation.
● Low self discharge.
● Case and cover avaiable in both standard
and flame restardant ABS.
Dimensions and Weight
Length(mm / inch)
Width(mm / inch)

Height(mm / inch)
Total Height(mm / inch)
Approx. Weight(Kg / lbs)

210 / 8.27
176 / 6.93
330 / 13.0
367 / 14.5
27 / 59.5

* Weight deviation: ± 3%
210

Separator

Electrolyte

PVC

Gelled acid

Performance Characteristics
Nominal Voltage
2V
Number of cell
1
Design Life
20 years
Nominal Capacity 77oF(25oC)
10 hour rate (40.0A, 10.8V)

400Ah
5 hour rate (68A, 10.5V)
340Ah
1 hour rate (248A, 9.6V)
248Ah
Internal Resistance
Fully Charged battery 77oF(25oC)
≤ 0.8mOhms
Self-Discharge
2% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
-20~60oC
Charge
-10~60oC
Storage
-20~60oC
1600A(5s)
Max. Discharge Current 77oF(25oC)
Charge Methods: Constant Voltage Charge 77oF(25oC)
Cycle use Charge Voltage:
2.40-2.45VPC
Maximum charging current
80A
-5mV/ oC
Temperature compensation
Standby use
2.20-2.30VPC
-3.3mV/ oC
Temperature compensation

Discharge Constant Current (Amperes at 77oF25oC)
End point
10min 15min 30min
volts/cell

1h

3h

5h

10h

20h

74.0 42.0 22.4
72.0 41.6 22.0

1.60V

750

630

410

248

112


1.65V

725

605

398

240

109

1.70V

698

580

384

232

106

1.75V

670

555


366

224

103

70.0 40.8 21.6
68.0 40.4 21.4

1.80V

640

530

350

212

100

65.6 40.0 21.0

Discharge Constant Power (Watts at 77oF25oC)
End point
10min 15min 30min
volts/cell

Total height with removeable cover: 367


1h

3h

5h

10h

20h

80.0 43.2
79.0 42.5

1.60V

1230

1050

749

464

195

138

1.65V

1180


1005

715

442

190

134

1.70V

1130

955

682

423

185

130

1.75V

1075

905


662

409

179

126

77.8 41.7
76.4 41.0

1.80V

1020

850

634

390

173

121

75.0 40.2

(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.

All data shall be changed without notice,Vision reserves the right to explain
and update the information contained hereinto.

page1 of 2

www.vision-batt.com


CG2-400
O

Charging characteristic for Cycle use
2.40

100

0.14

2.20

40A

400A 248A

80
60
40

Discharge


2.00

0.11

100%(0.1CAx10H)
---- 50%(0.1CAx5H)
Charge
Charge Voltage(2.45V/Cell)
Charge Current 0.1CA
o
Temperature25 C

1.80

0.08

1.60

0.05

1.40

0.02

20

)Ratio

Voltage(V)/PerCell


0.17

ChargeCurrent(CA)

750A

120

Charged Volume(%)

Battery voltage(V)

Discharge characteristic (25 C)

103A 68A

0

4

Discharge time

12

16

20

24


Self-discharge characteristic
110

(V/CELL)

100

15.6

10.4

7.8

5.2

2.6

15.0

10.0

7.5

5.0

2.5

14.4

9.6


7.2

4.8

2.4

13.8

9.2

6.9

4.6

2.3

13.2

8.8

6.6

4.4

2.2

-10

Capacity(%)


(V/6V)

(V/4V)

(V/8V)

8

Charging time (hours)

Relationship between
charging voltage and temperature
(V/12V)

2V 400Ah

90
80
70
60
50

0

10

20

30


40

50

40

60

Ambient temperature( oC)

0

3

6

9

12
15
18
21
Storage time: months

24

27

30


Cycle service life in relation to
depth of discharge

Capacity(%)

Life characteristics of Standby use

50% Depth of discharge

Number of cycles(cycles)

Life(year)

Temperature effects on capacity

Capacity (%)

Life(years)

Temperature effects on float life

Temperature( oC)

THE INTERNATIONAL CERTIFICATION NETWORK

ISO9001:2008

MH25860


G4M19906-9202-E-16

www.vision-batt.com

Shenzhen Center Power Tech. Co., Ltd.
Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail:
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2014-1)

Page 2 of 2



×