3FM180D-X 6V 180Ah(10hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte
is absorbed by separators and plates and thus immobilized. Should the battery be
accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the
gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is
completely sealed and is, therefore, maintenance-free, leak proof and usable in any position.
Battery Construction
Component
Positive plate
Negative plate
Container
Cover
Safety valve
Terminal
Separator
Electrolyte
Raw material
Lead dioxide
Lead
ABS
ABS
Rubber
Pb
Fiberglass
Sulfuric acid
General Features
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
ƽ
Absorbent Glass Mat (AGM) technology
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
UL-recognized component.
Can be mounted in any orientation.
Computer designed lead, calcium tin alloy
grid for high power density.
Long service life, float or cyclic
applications.
Maintenance-free operation.
Low self discharge.
Dimensions and Weight
Length(mm / inch)
306 / 12.0
Width(mm / inch)
Height(mm / inch)
164 / 6.46
220 / 8.66
Total Height(mm / inch)
Approx. Weight(Kg / lbs)
225 / 8.86
28.6 / 63.1
306±2
168±2
219
80
Performance Characteristics
Nominal Voltage
Number of cell
Design Life
Nominal Capacity 77oF(25oC)
10 hour rate (18.0A, 5.4V)
5 hour rate (32.8A, 5.25V)
1 hour rate (127A, 4.80V)
180Ah
164Ah
127Ah
Internal Resistance
Fully Charged battery 77oF(25oC)
2mOhms
Self-Discharge
3% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
-20~60oC
Charge
-10~60oC
Storage
-20~60oC
900A(5s)
Max. Discharge Current 77oF(25oC)
Short Circuit Current
3050A
Charge Methods: Constant Voltage Charge 77oF(25oC)
Cycle use
2.30-2.35VPC
Maximum charging current
54A
Temperature compensation
-30mV/oC
Standby use
2.23-2.27VPC
Temperature compensation
-20mV/oC
Discharge Constant Current (Amperes at 77oF25oC)
End Point
Volts/Cell
1.60V
1.65V
220±2
225±2
6V
3
10 years
1.70V
1.75V
1.80V
30min
45min
1h
220
211
202
193
183
159
155
151
147
143
127
125
123
121
118
3h
52.5
51.8
51.1
50.3
49.5
5h
10h
34.0
33.6
33.2
32.8
32.3
18.6
18.5
18.4
18.2
18.0
Discharge Constant Power (Watts at 77oF25oC)
End Point
Volts/Cell
Ø16
3
1.60V
1.65V
1.70V
1.75V
M8
1.80V
30min
397
383
369
354
339
45min
292
284
276
267
258
1h
251
246
241
235
229
2h
146
144
142
140
137
3h
5h
107
106
105
104
103
66.9
66.2
65.5
64.8
64.0
(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.
www.vision-batt.com
page1 of 2
(%)
140
Battery voltage(V)
50.3A32.8A
100
0.20
80
200A 127A
0.15
60
0.10
40
7.5
CHARGED VOLUME
7.0
CHARGE VOLTAGE
6.5
6.0
20 0.05 5.5
0
0
CHARGE CURRENT
0
4
2
6
8
Discharge time
(V/6V)
Relationship between
charging voltage and temperature
12
14
16
18
20
Self-discharge characteristic
110
100
90
CYC
Capacity(%)
LE U
7.5
SE
7.2
STAN
DB
6.9
Y USE
80
70
60
6.6
30℃
40℃
20℃
50
-10
0
10
20
30
40
50
40
60
0
2
4
6
8
10
12
14
Storage time: months
o
Ambient temperature( C)
120
120
Capacity(%)
80
40
Testing conditions: floating voltage: 2.27 to 2.30V/Cell
ambient temperature: 25℃ (77O F)
20
80
60
100% D.O.D.
50% D.O.D.
30 % Depth of discharge
40
20
0
18
100
100
60
16
Cycle service life in relation to
depth of discharge
Life characteristics of Standby use
Capacity(%)
10
Charging time (hours)
7.8
20
4
6
8
0
200
400
800
600
1000
1200
1400
1 600
40
50
Number of cycles(cycles)
Life(year)
Temperature effects on float life
Temperature effects on capacity
15
120
100
2.30V/Cell
Capacity (%)
Life(years)
180Ah
Constant voltage charging
characteristic (0.25CA,25 o C)
(xCA) (V)
120 0.25
18.0A
Voltage
Volume
O
Discharge characteristic (25 C)
Current
Charged
3FM180D-X 6V
5
0.1C
0.2C
80
60
1.0C
40
20
0
10
20
30
40
0
50
o
Temperature( C)
-10
0
10
20
30
Temperature (℃)
THE INTERNATIONAL CERTIFICATION NETWORK
ISO9001:2000
-20
MH25860
G4M19906-9202-E-16
www.vision-batt.com
Shenzhen Center Power Tech. Co., Ltd.
Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail:
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2011-8)
Page 2 of 2