Tải bản đầy đủ (.pdf) (2 trang)

Catalogue cấu tạo chi tiết sử dụng ắc QUY viễn thông 6FM100D x

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (103.37 KB, 2 trang )

6FM100D-X 12V 100Ah(20hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.
Battery Construction
Component

Positive plate

Negative plate

Container

Cover

Safety valve

Terminal

Separator

Electrolyte

Raw material

Lead dioxide

Lead


ABS

ABS

Rubber

Copper

Fiberglass

Sulfuric acid

General Features













Absorbent Glass Mat (AGM) technology
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.

Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
UL-recognized component.
Can be mounted in any orientation.
Computer designed lead, calcium tin alloy
grid for high power density.
Long service life, float or cyclic
applications.
Maintenance-free operation.
Low self discharge.

Dimensions and Weight
Length(mm / inch)
Width(mm / inch)
Height(mm / inch)
Total Height(mm / inch)
Approx. Weight(Kg / lbs)

330 / 12.99
171 / 6.73
215 / 8.46
220 / 8.66
32 / 70.5

Performance Characteristics
Nominal Voltage
Number of cell
Design Life
Nominal Capacity 77oF(25oC)
20 hour rate (5.00A, 10.8V)


100Ah

10 hour rate (9.50A, 10.8V)

95.0Ah

12V
6
10 years

5 hour rate (17.4A, 10.5V)
87.0Ah
1 hour rate (65.2A, 9.6V)
65.2Ah
Internal Resistance
5mOhms
Fully Charged battery 77oF(25oC)
Self-Discharge
3% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
-20~60oC
Charge
-10~60oC
Storage
-20~60oC
o
o
900A(5s)

Max. Discharge Current 77 F(25 C)
Short Circuit Current

2100A

Charge Methods: Constant Voltage Charge
Cycle use
Maximum charging current
Temperature compensation
Standby use
Temperature compensation

77oF(25oC)
2.30-2.35VPC
30A
-30mV/oC
2.23-2.27VPC
-20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)
End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V

5min


10min

15min

30min

45min

1h

3h

5h

10h

20h

298
281
257
230
210

220
212
192
180
168


180
173
159
148
139

105
101
93.6
90.7
88.7

78.9
77.1
71.5
69.9
68.6

65.2
61.6
60.6
59.6
56.5

27.6
27.4
26.9
26.6
25.1


18.9
18.2
17.9
17.4
17.1

9. 75
9. 70
9. 65
9. 60
9. 50

5.20
5.15
5.10
5.05
5.00

Discharge Constant Power (Watts at 77oF25oC)
End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V

5min

10min


15min

30min

45min

1h

2h

3h

5h

520
491
454
419
394

376
364
346
339
316

311
306
290

285
271

194
183
178
173
167

147
143
134
131
128

122
116
112
109
102

69.7
66.9
65.9
63.7
61.7

52.3
50.7
50.4

48.6
48.0

35.6
35.2
34.8
34.2
33.8

(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.

page1 of 2

www.vision-batt.com


Current

Charged
Volume

O

Discharge characteristic (25 C)

Voltage

6FM100D-X 12V100Ah
Charge characteristic curve

Constant voltage charge characteristic
(0.25CA,25 oC)

(%) (XCA) (V)

Battery voltage(V)

12.0

140

26.6A17.4A
9.6

9.50A

120

0.25

100

0.20

80

100A 65.2A

200A


0.15

1

2

3

5
10
min

20 30

60

2

3

5

10

20

0.10

20


0.05

0

0

h

CHARGED VOLUME

14.0

CHARGE VOLTAGE

13.0

60
40

0

15.0

12.0
11.0

0

Discharge time


(V/8V)

(V/6V)

(V/4V)

(V/CELL)

7.8

5.2

2.6

10.0

7.5

5.0

2.5

14.4

9.6

7.2

4.8


2.4

13.8

9.2

6.9

4.6

2.3

13.2

8.8

6.6

4.4

2.2

CY

CL

10

12


14

16

18

20

ND B

EU

SE

Y US

12
14
16
18
Storage time: months

20

90
80
70
60

E


40 oC

30 o C

20 o C

50
0

10
20
30
40
50
Ambient temperature( oC)

40

60

0

2

4

6

8


10

Cycle service life in relation to
depth of discharge

Life characteristics of standby use
120

120

100

100
Capacity(%)

Capacity(%)

8

110

-10

80
60

Testing conditions: floating voltage: 2.27 to 2.30V/Cell
o
o

ambient temperature: 25 C(77 F)

80
60

40

40

20

20

0

4

6
Life(year)

100% D.O.D.

0

8

200

30% Depth of discharge


50% D.O.D.

400

600

800

1000

1200

1400

1600

Number of cycles(cycles)

Temperature effects on float life

Temperature effects on capacity
120

15

100
2.30V/Cell

10


Capacity (%)

Life(years)

6

100

S TA

0

4

Self-discharge characteristic

Capacity(%)

(V/12V)

10.4

15.0

2

Charging time (hours)

Relationship between
charging voltage and temperature


15.6

CHARGING CURRENT

5

C
0 .0 5
0 .1 C
0 .2 C

80
60

1.0C
2.0C

40
20

0

10

20

30

40


0

50

-20

-10

o

Temperature( C)

THE INTERNATIONAL CERTIFICATION NETWORK

ISO9001:2000

MH25860

0

10
20
Temperature( oC)

30

40

G4M19906-9202-E-16


www.vision-batt.com

Shenzhen Center Power Tech. Co., Ltd.
Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail:
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2011-8)

Page 2 of 2

50



×