6FM90T D-X
12V 90Ah(20hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.
Battery Construction
Component
Positive plate
Negative plate
Container
Cover
Safety valve
Terminal
Separator
Electrolyte
Raw material
Lead dioxide
Lead
ABS
ABS
Rubber
Copper
Fiberglass
Sulfuric acid
General Features
●
●
●
●
●
●
●
●
Absorbent Glass Mat (AGM) technology
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
UL-recognized component.
Can be mounted in any orientation.
Computer designed lead, calcium tin alloy
grid for high power density.
Long service life, float or cyclic
applications.
Maintenance-free operation.
Low self discharge.
Dimensions and Weight
Length(mm / inch)
Width(mm / inch)
Height(mm / inch)
Total Height(mm / inch)
Approx. Weight(Kg / lbs)
306 / 12.05
169 / 6.65
210 / 8.27
215 / 8.46
29 / 63.9
Performance Characteristics
Nominal Voltage
Number of cell
Design Life
Nominal Capacity 77oF(25oC)
20 hour rate (4.50A, 10.8V)
10 hour rate (8.86A, 10.8V)
5 hour rate (16.1A, 10.5V)
1 hour rate (61.1A, 9.6V)
Internal Resistance
Fully Charged battery 77oF(25oC)
12V
6
10 years
90Ah
88.6Ah
80.5Ah
61.1Ah
5.1mOhms
Self-Discharge
3% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
Charge
Storage
Max. Discharge Current 77oF(25oC)
-20~60oC
-10~60oC
-20~60oC
800A(5s)
Short Circuit Current
2000A
Charge Methods: Constant Voltage Charge 77oF(25oC)
Cycle use
2.30-2.35VPC
Maximum charging current
27A
Temperature compensation
-30mV/oC
Standby use
2.23-2.27VPC
Temperature compensation
-20mV/oC
Discharge Constant Current (Amperes at 77oF25oC)
End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V
5min
10min
15min
30min
45min
1h
3h
5h
10h
20h
274
256
240
217
193
210
200
179
168
157
168
157
149
138
128
97.6
92.7
87.8
85.2
82.1
73.2
70.1
66.6
64.2
61.8
61.1
55.8
55.2
53.8
51.6
26.7
25.7
24.8
24.0
22.9
17.1
16.9
16.6
16.1
15.6
8.98
8.96
8.93
8.90
8.86
4.61
4.54
4.52
4.50
4.65
Discharge Constant Power (Watts at 77oF25oC)
End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V
5min
10min
15min
30min
45min
1h
2h
3h
5h
491
479
430
405
372
359
350
332
330
302
299
294
276
273
259
184
176
167
163
159
142
136
126
125
123
115
110
105
101
99.5
64.7
63.3
61.0
59.0
58.3
47.8
47.7
46.3
45.0
44.8
32.1
31.7
31.3
30.5
30.1
(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.
page1 of 2
www.vision-batt.com
Current
Charged
Volume
O
Discharge characteristic (25 C)
Voltage
6FM90TD-X
Charge characteristic curve
Constant voltage charge characteristic
(0.25CA,25 oC)
(%) (XCA) (V)
Battery voltage(V)
12.0
140
24.0A 16.1A
9.6
8.86A
120
0.25
100
0.20
80
90A 61.1A
180A
0.15
1
2
3
20 30
5
10
min
60
2
3
5
10
20
0.10
20
0.05
0
0
h
15.0
CHARGED VOLUME
14.0
CHARGE VOLTAGE
13.0
60
40
0
12.0
11.0
(V/8V)
(V/6V)
(V/4V)
(V/CELL)
7.8
5.2
2.6
10.0
7.5
5.0
2.5
14.4
9.6
7.2
4.8
2.4
13.8
9.2
6.9
4.6
2.3
13.2
8.8
6.6
4.4
2.2
8
10
12
14
16
18
20
12
14
16
18
Storage time: months
20
110
CY
CL
ND B
EU
SE
Y US
90
80
70
60
E
40 oC
30 o C
20 o C
50
-10
0
10
20
30
40
50
Ambient temperature( oC)
40
60
0
2
4
6
8
10
Cycle service life in relation to
depth of discharge
Life characteristics of standby use
120
120
100
100
Capacity(%)
Capacity(%)
6
100
S TA
80
60
Testing conditions: floating voltage: 2.27 to 2.30V/Cell
o
o
ambient temperature: 25 C(77 F)
80
60
40
40
20
20
0
4
Self-discharge characteristic
Capacity(%)
(V/12V)
10.4
15.0
2
Charging time (hours)
Relationship between
charging voltage and temperature
15.6
CHARGING CURRENT
0
Discharge time
0
4
6
Life(year)
100% D.O.D.
0
8
200
30% Depth of discharge
50% D.O.D.
400
600
800
1000
1200
1400
1600
Number of cycles(cycles)
Temperature effects on float life
Temperature effects on capacity
120
15
100
C
0 .0 5
0 .1 C
0 .2 C
2.30V/Cell
10
Capacity (%)
Life(years)
12V 90Ah
5
80
60
1.0C
2.0C
40
20
0
10
20
30
40
0
50
-20
-10
Temperature( o C)
THE INTERNATIONAL CERTIFICATION NETWORK
ISO9001:2000
MH25860
0
10
20
Temperature( oC)
30
40
G4M19906-9202-E-16
www.vision-batt.com
Shenzhen Center Power Tech. Co., Ltd.
Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail:
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2011-8)
Page 2 of 2
50