6FM80D-X 12V 75.6Ah(20hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.
Battery Construction
Component

Positive plate

Negative plate

Container

Cover

Safety valve

Terminal

Separator

Electrolyte

Raw material

Lead dioxide

Lead


ABS

ABS

Rubber

Copper

Fiberglass

Sulfuric acid

General Features













Absorbent Glass Mat (AGM) technology
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.

Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
UL-recognized component.
Can be mounted in any orientation.
Computer designed lead, calcium tin alloy
grid for high power density.
Long service life, float or cyclic
applications.
Maintenance-free operation.
Low self discharge.

Dimensions and Weight
Length(mm / inch)
Width(mm / inch)
Height(mm / inch)
Total Height(mm / inch)
Approx. Weight(Kg / lbs)

350 / 13.78
167 / 6.57
179 / 7.05
179 / 7.05
22.5 / 49.6

Performance Characteristics
Nominal Voltage
12V
Number of cell
6
Design Life

10 years
o
o
Nominal Capacity 77 F(25 C)
20 hour rate (3.78A, 10.8V)
75.6Ah
10 hour rate (7.20A, 10.8V)
72.0Ah
5 hour rate (12.9A, 10.5V)
64.5Ah
1 hour rate (47.6A, 9.6V)
47.6Ah
Internal Resistance
5.5mOhms
Fully Charged battery 77oF(25oC)
Self-Discharge
3% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
-20~60oC
Charge
-10~60oC
Storage
-20~60oC
o
o
750A(5s)
Max. Discharge Current 77 F(25 C)
Short Circuit Current


1900A

Charge Methods: Constant Voltage Charge
Cycle use
Maximum charging current
Temperature compensation
Standby use
Temperature compensation

77oF(25oC)
2.30-2.35VPC
24A
-30mV/oC
2.23-2.27VPC
-20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)
End Voltage
Volts/Cell

5min

10min

15min

30min

1h


3h

5h

10h

20h

1.60V

212

163

130

76.7

47.6

20.2

13.5

7.38

3.85

1.65V


200

154

120

72.9

45.8

20

13.3

7.34

3.84

1.70V

187

145

115

70.5

44.2


19.7

13.1

7.29

3.82

1.75V

175

138

110

68.1

41.8

19.4

12.9

7.25

3.80

1.80V


163

129

103

65.9

41.1

18.4

12.6

7.20

3.78

5h

Discharge Constant Power (Watts at

77oF25oC)

End Voltage
Volts/Cell

5min

10min


15min

30min

45min

1h

2h

3h

1.60V

371

280

225

145

109

87.4

54

37.8


25

1.65V

360

268

218

138

108

86.7

53.5

36.5

24.5

1.70V

334

259

215


133

103

83.2

52.6

35.9

24.2

1.75V

315

248

203

131

101

81.8

51.6

35.4


24

1.80V

299

238

190

128

98

78.5

50.7

34.6

23.6

(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.

page1 of 2

www.vision-batt.com



Voltage

O

Discharge characteristic (25 C)

Current

Charged
Volume

6FM80D-X 12V75.6Ah
Charge characteristic curve
Constant voltage charge characteristic
(0.25CA,25 oC)

(%) (XCA) (V)

Battery voltage(V)

12.0

140

19.4A 12.9A

7.2A

120


0.25

100

0.20

80

0.15

9.6

75A 47.6A

150A

1

2

3

5
10
min

20 30

60


2

3

5

10

20

0.10

20

0.05

0

0

h

CHARGED VOLUME

14.0

CHARGE VOLTAGE

13.0


60
40

0

15.0

12.0
11.0

CHARGING CURRENT

0

2

4

6

(V/8V)

(V/6V)

(V/4V)

(V/CELL)

10.4


7.8

5.2

2.6

15.0

10.0

7.5

5.0

2.5

14.4

9.6

7.2

4.8

2.4

13.8

9.2


6.9

4.6

2.3

13.2

8.8

6.6

4.4

2.2

CY

CL

16

18

20

ND B

EU


SE

Y US

12
14
16
18
Storage time: months

20

90
80
70
60

E

40 oC

30 o C

20 o C

50
0

10

20
30
40
50
Ambient temperature( oC)

40

60

0

2

4

6

8

10

Cycle service life in relation to
depth of discharge

Life characteristics of standby use
120

120


100

100
Capacity(%)

Capacity(%)

14

110

-10

80
60

Testing conditions: floating voltage: 2.27 to 2.30V/Cell
o
o
ambient temperature: 25 C(77 F)

80
60

40

40

20


20

0

4

6
Life(year)

100% D.O.D.

0

8

200

30% Depth of discharge

50% D.O.D.

400

600

800

1000

1200


1400

1600

Number of cycles(cycles)

Temperature effects on float life

Temperature effects on capacity
120

15

100
2.30V/Cell

10

Capacity (%)

Life(years)

12

100

S TA

0


10

Self-discharge characteristic

Capacity(%)

(V/12V)

Relationship between
charging voltage and temperature

15.6

8

Charging time (hours)

Discharge time

5

C
0 .0 5
0 .1 C
0 .2 C

80
60


1.0C
2.0C

40
20

0

10

20

30

40

0

50

-20

-10

Temperature( o C)

THE INTERNATIONAL CERTIFICATION NETWORK

ISO9001:2000


MH25860

0

10
20
Temperature( oC)

30

40

G4M19906-9202-E-16

www.vision-batt.com

Shenzhen Center Power Tech. Co., Ltd.
Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail:
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2011-8)

Page 2 of 2

50



×