6FM75TD-X
12V 75Ah(20hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte
is absorbed by separators and plates and thus immobilized. Should the battery be
accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the
gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is
completely sealed and is, therefore, maintenance-free, leak proof and usable in any position.
Battery Construction
Component
Positive plate
Negative plate
Container
Cover
Safety valve
Terminal
Separator
Electrolyte
Raw material
Lead dioxide
Lead
ABS
ABS
Rubber
Copper
Fiberglass
Sulfuric acid
General Features
●
●
●
●
●
●
●
●
Absorbent Glass Mat (AGM) technology
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
UL-recognized component.
Can be mounted in any orientation.
Computer designed lead, calcium tin alloy
grid for high power density.
Long service life, float or cyclic
applications.
Maintenance-free operation.
Low self discharge.
Dimensions and Weight
Length(mm / inch)
Width(mm / inch)
Height(mm / inch)
Total Height(mm / inch)
Approx. Weight(Kg / lbs)
258 / 10.16
166 / 6.54
206 / 8.11
211 / 8.31
24.0 / 52.9
211±1
206±1
166±1
Performance Characteristics
Nominal Voltage
12V
Number of cell
6
Design Life
10 years
Nominal Capacity 77oF(25oC)
75Ah
20 hour rate (3.75A, 10.8V)
74.1Ah
10 hour rate (7.41A, 10.8V)
67.0Ah
5 hour rate (13.4A, 10.5V)
49.5Ah
1 hour rate (49.5A, 9.6V)
Internal Resistance
5.3mOhms
Fully Charged battery 77oF(25oC)
Self-Discharge
3% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge
-20~60oC
Charge
-10~60oC
Storage
-20~60oC
o
o
700A(5s)
Max. Discharge Current 77 F(25 C)
Short Circuit Current
1800A
Charge Methods: Constant Voltage Charge
Cycle use
Maximum charging current
Temperature compensation
Standby use
Temperature compensation
77oF(25oC)
2.30-2.35VPC
22.5A
-30mV/oC
2.23-2.27VPC
-20mV/oC
Discharge Constant Current (Amperes at 77oF25oC)
End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V
5min
10min
15min
30min
45min
1h
3h
5h
10h
20h
228
211
196
185
171
171
162
152
145
133
133
127
118
114
109
79.8
76.3
75.1
71.8
71.3
60.5
55.3
53.9
52.6
52.2
49.5
46.8
46.2
44.6
42.8
21.6
21.2
20.8
20.4
19.6
14.2
14.0
13.8
13.4
13.2
7.54
7.51
7.48
7.45
7.41
3.94
3.90
3.85
3.80
3.75
63±1
Discharge Constant Power (Watts at 77oF25oC)
End Point
Volts/Cell
1.60V
1.65V
1.70V
1.75V
1.80V
5min
10min
15min
30min
45min
1h
2h
3h
5h
392
383
356
338
324
301
288
278
263
251
239
234
230
216
206
154
149
141
139
138
118
116
109
109
104
94.3
92.2
88.5
85.2
82.9
53.4
52.1
50.9
49.7
49.0
39.8
38.8
38.5
37.9
37.6
26.7
26.5
25.9
25.9
25.7
206
(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.
page1 of 2
www.vision-batt.com
Current
Charged
Volume
O
Discharge characteristic (25 C)
Voltage
6FM75TD-X
Charge characteristic curve
Constant voltage charge characteristic
(0.25CA,25 oC)
(%) (XCA) (V)
Battery voltage(V)
12.0
140
20.4A 13.4A
7.41A
120
0.25
100
0.20
80
9.6
70A 49.5A
150A
0.15
1
2
3
20 30
5
10
min
60
2
3
5
10
20
0.10
20
0.05
0
0
h
15.0
CHARGED VOLUME
14.0
CHARGE VOLTAGE
13.0
60
40
0
12.0
11.0
(V/8V)
(V/6V)
(V/4V)
(V/CELL)
7.8
5.2
2.6
10.0
7.5
5.0
2.5
14.4
9.6
7.2
4.8
2.4
13.8
9.2
6.9
4.6
2.3
13.2
8.8
6.6
4.4
2.2
8
10
12
14
16
18
20
12
14
16
18
Storage time: months
20
110
CY
CL
ND B
EU
SE
Y US
90
80
70
60
E
40 oC
30 o C
20 o C
50
-10
0
10
20
30
40
50
Ambient temperature( oC)
40
60
0
2
4
6
8
10
Cycle service life in relation to
depth of discharge
Life characteristics of standby use
120
120
100
100
Capacity(%)
Capacity(%)
6
100
S TA
80
60
Testing conditions: floating voltage: 2.27 to 2.30V/Cell
o
o
ambient temperature: 25 C(77 F)
80
60
40
40
20
20
0
4
Self-discharge characteristic
Capacity(%)
(V/12V)
10.4
15.0
2
Charging time (hours)
Relationship between
charging voltage and temperature
15.6
CHARGING CURRENT
0
Discharge time
0
4
6
Life(year)
100% D.O.D.
0
8
200
30% Depth of discharge
50% D.O.D.
400
600
800
1000
1200
1400
1600
Number of cycles(cycles)
Temperature effects on float life
Temperature effects on capacity
120
15
100
C
0 .0 5
0 .1 C
0 .2 C
2.30V/Cell
10
Capacity (%)
Life(years)
12V 75Ah
5
80
60
1.0C
2.0C
40
20
0
10
20
30
40
0
50
-20
-10
Temperature( o C)
THE INTERNATIONAL CERTIFICATION NETWORK
ISO9001:2000
MH25860
0
10
20
Temperature( oC)
30
40
G4M19906-9202-E-16
www.vision-batt.com
Shenzhen Center Power Tech. Co., Ltd.
Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail:
Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2011-8)
Page 2 of 2