Tải bản đầy đủ (.pdf) (104 trang)

Flexi multiradio BTS GSM EDGE optional items description

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (3.17 MB, 104 trang )

Nokia Siemens Networks
GSM/EDGE BSS, rel.
RG20(BSS), operating
documentation, issue 03

Flexi Multiradio BTS GSM/EDGE Optional
Items Description
DN0946895
Issue 02A
Approval Date 2010-12-20

Confidential


Flexi Multiradio BTS GSM/EDGE Optional Items Description

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia


Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2010. All rights reserved

f

Important Notice on Product Safety
Elevated voltages are inevitably present at specific points in this electrical equipment.
Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal
injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected
has to comply with the applicable safety standards.

The same text in German:
Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Spannung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverletzungen und Sachschäden führen.

Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die
Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene
Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.

2

Id:0900d8058082e825
Confidential

DN0946895
Issue 02A


Flexi Multiradio BTS GSM/EDGE Optional Items Description

Table of contents
This document has 104 pages.
1

Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2

Introduction to Optional Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3

3.3
3.4


Flexi Power Module (FPMA) and submodules (FPAA and FPBA) description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA/B) operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Flexi Power Module (FPMA) and sub-module (FPAA and FPBA/B) interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Flexi Power Module (FPMA) dimensions and weight . . . . . . . . . . . . . . 18
Flexi power sub-module (FPAA and FPBA/B) LED indications . . . . . . . 19

4
4.1
4.2
4.3
4.4

Flexi Power DC/DC Sub-Module (FPDA) description . . . . . .
Flexi Power DC/DC Module (FPDA) operation . . . . . . . . . . .
Flexi Power DC/DC Module (FPDA) interfaces . . . . . . . . . . .
Flexi Power DC/DC Module (FPDA) dimensions and weight
Flexi Power DC/DC Module (FPDA) LED indications . . . . . .

.
.
.
.
.

21
21
22
23
24


5
5.1
5.1.1
5.1.2
5.1.3
5.2
5.3

Diplexer Unit (DU2A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical description of Dual Band Diplex Filter (DU2A) unit . . . . . . . .
Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Main blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interfaces of the Dual Band Diplex Filter (DU2A) unit . . . . . . . . . . . . . .
Dimensions and weight of Dual Band Diplex Filter (DU2A) unit . . . . . .

25
25
25
25
26
27
28

6

Flexi Mounting Auxiliary Bracket (FMAA) description . . . . . . . . . . . . . . 29

7

7.1
7.2
7.3

Flexi System
Flexi System
Flexi System
Flexi System

8

Flexi System External OVP (FSEC) description . . . . . . . . . . . . . . . . . . 34

9
9.1
9.2
9.3
9.4

Flexi Cabinet for Indoor (FCIA) . . . . . . . . . .
FCIA cabinet construction . . . . . . . . . . . . . .
FCIA cabinet locking . . . . . . . . . . . . . . . . . .
FCIA dimensions and weight . . . . . . . . . . . .
FCIA optional items . . . . . . . . . . . . . . . . . . .

.
.
.
.
.


38
38
39
40
41

10
10.1
10.2
10.3

Flexi Cabinet for Outdoor (FCOA) description . . . . . . . . . . . . . . . . . . . .
Flexi Cabinet for Outdoor (FCOA) construction . . . . . . . . . . . . . . . . . . .
FCOA optional items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flexi Cabinet for Outdoor (FCOA) dimensions and weight . . . . . . . . . .

42
42
43
46

11
11.1
11.2

Flexi Mounting Shield (FMSA/FMSB) description . . . . . . . . . . . . . . . . . 47
Flexi Mounting Shield (FMSA and FMSB) operation and construction . 47
Flexi Mounting Shield (FMSA and FMSB) dimensions and weights . . . 49


3.1
3.2

DN0946895
Issue 02A

.......
.......
.......
.......
.......

External Alarm Box (FSEB) . . . . . . . . . . . . . . . . . . . . . . .
External Alarm Box (FSEB) operation . . . . . . . . . . . . . . .
External Alarm (FSEB) interfaces . . . . . . . . . . . . . . . . . .
External Alarm (FSEB) dimensions and weight . . . . . . . .

Id:0900d8058082e825
Confidential

.......
.......
.......
.......
.......

......
......
......
......

......

.......
.......
.......
.......
.......

30
30
31
33

3


Flexi Multiradio BTS GSM/EDGE Optional Items Description

12
12.1

4

12.2

Flexi Mounting Kit Horizontal for 2G (FMUB) description . . . . . . . . . . . . 50
Flexi Mounting Kit Horizontal for 2G (FMUB) operation and construction .
50
Technical properties of Flexi Mounting Kit Horizontal for 2G (FMUB) . . 51


13

Flexi BTS Module Casing (EMHA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

14

Flexi BTS Module Casing (EMHA) dimensions and weight . . . . . . . . . . 55

15

Flexi Mounting Kit for Floor, Wall and Pole (FMFA) description . . . . . . . 56

16

Flexi Pole Installation Kit (FPIA) description . . . . . . . . . . . . . . . . . . . . . . 60

17

Flexi Pole Mounting Kit (FPKA) description . . . . . . . . . . . . . . . . . . . . . . 61

18

Pole Mounting Kit (VMPB) description . . . . . . . . . . . . . . . . . . . . . . . . . . 63

19

Flexi Mounting Covers for Back and Front (FMCA and FMCB) description
64

20


Multi Integrated Battery Backup Solution (MIBBU) . . . . . . . . . . . . . . . . . 66

21

Talk Conversion Kit (EMIA or EMIB). . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

22

Upgrade Cable Kit (EUCA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

23

LMP cable delivery (ELCA). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

24

BBU Alarm Cable delivery (EBCA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

25

IDC_ Roof and Side Kit (IRSA) and Outdoor Side Kit (OSKA) . . . . . . . . 72

26

Rx Diversity Sharing Kits (RDSA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

27
27.1
27.1.1

27.1.2
27.2
27.3
27.4
27.5
27.6
27.7
27.8
27.9
27.10
27.11
27.12
27.13
27.14
27.15
27.16
27.17
27.18
27.19

Appendix: Contents of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Contents of the Power Module (FPMA) delivery . . . . . . . . . . . . . . . . . . . 74
Contents of the power AC/DC sub-module (FPAA) delivery. . . . . . . . . . 75
Contents of the power battery sub-module (FPBA/B) delivery . . . . . . . . 75
Contents of the 24V Power Module (FPDA) delivery . . . . . . . . . . . . . . . 77
Contents of the Flexi System External Alarm Module (FSEB) . . . . . . . . 78
Contents of the Upgrade Cable Kit (EUCA) delivery . . . . . . . . . . . . . . . 79
Contents of the Flexi Pole Installation Kit (FPIA) delivery. . . . . . . . . . . . 80
Contents of the Flexi Pole Mounting Kit (FPKA) delivery . . . . . . . . . . . . 81
Contents of the Pole Mounting Kit delivery (VMPB) . . . . . . . . . . . . . . . . 82

Contents of Flexi Cabinet for Indoor (FCIA) delivery . . . . . . . . . . . . . . . 83
Contents of the Flexi Mounting Kit for Batteries (FMBB) delivery . . . . . . 84
Contents of the Flexi Mounting Shield 6U (FMSA) delivery . . . . . . . . . . 85
Contents of the Flexi Mounting Shield 18U (FMSB) delivery . . . . . . . . . 86
Contents of the 3 U Module Casings (EMHA) delivery . . . . . . . . . . . . . . 87
Contents of the mounting kit for floor, wall and pole (FMFA) delivery . . 88
Contents of the Flexi Mounting Covers Front and Back, 2 HU (FMCB) . 90
Contents of Long Term Battery Backup Solution (MIBBU) delivery . . . . 91
Contents of the Talk Conversion Kit (EMIA) delivery . . . . . . . . . . . . . . . 92
Contents of the Talk Conversion Kit (EMIB) delivery . . . . . . . . . . . . . . . 94
Contents of the Flexi Mounting Auxiliary Bracket (FMAA) . . . . . . . . . . . 97
Contents of the LMP cable delivery (ELCA) . . . . . . . . . . . . . . . . . . . . . . 98

Id:0900d8058082e825
Confidential

DN0946895
Issue 02A


Flexi Multiradio BTS GSM/EDGE Optional Items Description

27.20
27.21
27.22
27.23
27.24
27.25

DN0946895

Issue 02A

Contents the of BBU Alarm Cable delivery (EBCA). . . . . . . . . . . . . . . . 99
Contents of the synchronisation cable deliveries (ESxA) . . . . . . . . . . 100
Contents of the Q1 cable delivery (EQCA) . . . . . . . . . . . . . . . . . . . . . 101
Contents of the Flexi System Alarm Cable (FSAA) delivery . . . . . . . . 102
Contents of the Rx Diversity Sharing Kits (RDSA) delivery . . . . . . . . . 103
Contents of Flexi System External OVP (FSEC) delivery . . . . . . . . . . 104

Id:0900d8058082e825
Confidential

5


Flexi Multiradio BTS GSM/EDGE Optional Items Description

List of figures
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12

Figure 13
Figure 14
Figure 15
Figure 16
Figure 17
Figure 18
Figure 19
Figure 20
Figure 21
Figure 22
Figure 23
Figure 24
Figure 25
Figure 26
Figure 27
Figure 28
Figure 29
Figure 30
Figure 31
Figure 32
Figure 33
Figure 34
Figure 35
Figure 36
Figure 37
Figure 38
Figure 39
Figure 40
Figure 41
Figure 42

Figure 43

6

Power Module (FPMA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
FPMA: full configuration with two FPAAs and two FPBAs . . . . . . . . . . . 14
FPAA LED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
FPBA/B LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Flexi Power DC/DC Module (FPDA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Front panel of the FPDA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
DU2A unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
DU2A main blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Flexi Mounting Auxiliary Bracket (FMAA) . . . . . . . . . . . . . . . . . . . . . . . . 29
FSEB interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
FSEB PWB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Isometric view of the FSEC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
FSEC internal wiring (version 6Yxxxxxxxxx). . . . . . . . . . . . . . . . . . . . . . 35
FSEC external wiring (version 6Yxxxxxxxxx) . . . . . . . . . . . . . . . . . . . . . 36
FCIA cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
FCOA cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Air filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Site support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Heat detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Isometric view of the FMSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Isometric view of the FMSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Isometric view of Flexi Mounting Kit Horizontal for 2G . . . . . . . . . . . . . . 50
EMHA casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Flexi BTS Side Covers (FMTA). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Flexi BTS Side Covers (FMHA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Isometric view of FMFA v. 104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Isometric view of FMFA v. 103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Adapter mechanics (used with FMFA version 103 or older) . . . . . . . . . . 57
External interfaces of the plinth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Flexi Pole Installation Kit (FPIA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Flexi Pole Mounting Kit (FPKA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
FPKA with four 3U Flexi Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Pole Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
FMCA: 3U back cover, 3U front cover, 2 x maintenance strap and grounding cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Parts needed for installing Flexi Multiradio BTS modules in Citytalk cabinet
with Talk Conversion Kit EMIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Parts needed for installing Flexi Multiradio BTS modules in Citytalk cabinet
with Talk Conversion Kit EMIB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Example of EUCA usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Delivery contents of the FPMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Delivery contents of the FPAA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Delivery contents of the FPBA/B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Delivery contents of the FPDA delivery . . . . . . . . . . . . . . . . . . . . . . . . . 77
Delivery contents of the FSEB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Delivery contents of the FPIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

Id:0900d8058082e825
Confidential

DN0946895
Issue 02A


Flexi Multiradio BTS GSM/EDGE Optional Items Description

Figure 44

Figure 45
Figure 46
Figure 47
Figure 48
Figure 49
Figure 50
Figure 51
Figure 52
Figure 53

DN0946895
Issue 02A

Flexi pole mounting kit (FPKA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Contents of the Pole Mounting Kit (VMPB) delivery . . . . . . . . . . . . . . . 82
Delivery contents of the FMBB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Delivery contents of FMFA v. 104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Delivery contents of FMFA v. 103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
The Talk Conversion Kit (EMIA) delivery contents . . . . . . . . . . . . . . . . 92
The Talk Conversion Kit (EMIB) delivery contents . . . . . . . . . . . . . . . . 94
Contents of the Assembly accessories bag (included in the EMIB delivery)
94
Contents of the Door sensor accessories bag (included in the EMIB delivery). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Delivery contents of the FMAA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

Id:0900d8058082e825
Confidential

7



Flexi Multiradio BTS GSM/EDGE Optional Items Description

List of tables
Table 1
Table 2
Table 3
Table 4
Table 5
Table 6
Table 7
Table 8
Table 9
Table 10
Table 11
Table 12
Table 13
Table 14
Table 15
Table 16
Table 17
Table 18
Table 19
Table 20
Table 21
Table 22
Table 23
Table 24
Table 25
Table 26

Table 27
Table 28
Table 29
Table 30
Table 31
Table 32
Table 33
Table 34
Table 35
Table 36
Table 37
Table 38
Table 39
Table 40
Table 41
Table 42
Table 43
Table 44

8

FPMA front panel connectors, types and purposes . . . . . . . . . . . . . . . . 16
FPAA front panel connectors, types and purposes . . . . . . . . . . . . . . . . 16
FPBA/B front panel connectors, types and purposes . . . . . . . . . . . . . . 16
Dimensions and weight of the FPMA . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
FPAA LED indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
FPBA/B LED indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
FPDA front panel connectors, connector types and purposes . . . . . . . . 22
Dimensions and weight of the FPDA . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
FPDA LED indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

RF connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Dimensions and weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Interface and connector overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
FSEB dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
FSEC dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
FSEC E4xxxxxxxxx and S1xxxxxxxxx LED indications . . . . . . . . . . . . . 37
Dimensions and weight of Flexi Cabinet for Indoor (FCIA). . . . . . . . . . . 40
Dimensions and weight of the Flexi Cabinet for Outdoor (FCOA) . . . . . 46
Dimensions and weight of Flexi Mounting Shield 6U (FMSA) . . . . . . . . 49
Dimensions and weight of Flexi Mounting Shield 18U (FMSB) . . . . . . . 49
Dimensions and weight of the EMHA. . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Dimensions and weight of the FMFA . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
FPKA delivery contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Delivery contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
VMPB dimensions and weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Dimensions of the FMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Dimensions of the FMCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Grounding cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
The Power Module (FPMA) delivery content . . . . . . . . . . . . . . . . . . . . . 74
The FPAA power sub-module delivery content . . . . . . . . . . . . . . . . . . . 75
The FPBA/B power sub-module delivery content . . . . . . . . . . . . . . . . . 75
The 24V Power Module (FPDA) delivery content . . . . . . . . . . . . . . . . . 77
Flexi System External Alarm Module (FSEB) delivery contents . . . . . . 78
The Flexi BTS Upgrade Cable Kit (EUCA) delivery contents . . . . . . . . 79
The Flexi Pole Installation Kit (FPIA) delivery content . . . . . . . . . . . . . . 80
The Flexi pole mounting kit (FPKA) delivery content . . . . . . . . . . . . . . . 81
Contents of the Pole Mounting Kit (VMPB) delivery . . . . . . . . . . . . . . . 82
The Flexi Cabinet for Indoor (FCIA) delivery contents . . . . . . . . . . . . . . 83
Flexi Mounting Kit for Batteries (FMBB) delivery (used with Flexi Cabinet
for Indoor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

The Flexi Mounting Shield 6U (FMSA) delivery content . . . . . . . . . . . . 85
The Flexi Mounting Shield 18U (FMSB) delivery content . . . . . . . . . . . 86
The Flexi Module Casings for 3 U modules (EMHA) delivery contents . 87
The FMFA v. 104 delivery content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
The FMFA v. 103 delivery content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
The Flexi Mounting Covers Front and Back, 2 HU (FMCB), needed with
Flexi Power DC/ DC Module 24 V (FPDA) . . . . . . . . . . . . . . . . . . . . . . . 90

Id:0900d8058082e825
Confidential

DN0946895
Issue 02A


Flexi Multiradio BTS GSM/EDGE Optional Items Description

Table 45
Table 46
Table 47
Table 48
Table 49
Table 50
Table 51
Table 52
Table 53
Table 54
Table 55

DN0946895

Issue 02A

The Long Term Battery Backup Solution (MIBBU) delivery content . . . 91
The Talk Conversion Kit (EMIA) delivery contents . . . . . . . . . . . . . . . . 92
The Talk Conversion Kit (EMIB) delivery contents . . . . . . . . . . . . . . . . 95
The Flexi Mounting Auxiliary Bracket (FMAA) delivery contents . . . . . 97
LMP cable delivery (ELCA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
BBU Alarm Cable Kit delivery (EBCA) . . . . . . . . . . . . . . . . . . . . . . . . . 99
Synchronisation cable deliveries (ESUA/ESFA/ESLA) . . . . . . . . . . . . 100
Q1 cable delivery (EQCA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Flexi System Alarm Cable (FSAA) . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Rx Diversity Sharing Kit (RDSA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Flexi System External OVP (FSEC) . . . . . . . . . . . . . . . . . . . . . . . . . . 104

Id:0900d8058082e825
Confidential

9


Flexi Multiradio BTS GSM/EDGE Optional Items Description

10

Id:0900d8058082e825
Confidential

DN0946895
Issue 02A



Flexi Multiradio BTS GSM/EDGE Optional Items Description

Summary of changes

1 Summary of changes
Changes between issues 02A and 02
Updated section:


Contents of the Rx Diversity Sharing Kit (RDSA) delivery is updated for the cable
code and quantity.

New section added:



Rx Diversity Sharing Kits (RDSA).
Contents of Flexi System External OVP (FSEC) delivery

Changes between issues 02 and 01
Updated chapter:


FCOA optional items: note about the allowed temperature for FCSA added.

Added Chapter:


DN0946895

Issue 02A

Contents of the Rx Diversity Sharing Kits delivery.

Id:0900d8058082ebd3
Confidential

11


Introduction to Optional Items

Flexi Multiradio BTS GSM/EDGE Optional Items Description

2 Introduction to Optional Items
This document describes the optional items available for Flexi Multiradio BTS. It
describes the modules in terms of their function as well as their dimensions and weight
and the interfaces, if applicable. The document also lists the ordering codes for the
optional items.

12

Id:0900d805806d9a4d
Confidential

DN0946895
Issue 02A


Flexi Multiradio BTS GSM/EDGE Optional Items Description


Flexi Power Module (FPMA) and submodules (FPAA
and FPBA) description

3 Flexi Power Module (FPMA) and submodules
(FPAA and FPBA) description
3.1

Flexi Power Module (FPMA) and sub-modules (FPAA and
FPBA/B) operation
Flexi Power Module (FPMA) is an optional module. In a BTS site with AC feed only, a
Flexi Power Module (FPMA) is required for converting the AC to DC before feeding the
DC power to the System Module. It comprises FPMA mechanics and AC and DC interfaces. The actual power sub-modules are the following:



Flexi Power AC/DC sub-module 200-240 V AC (FPAA)
Flexi Power Battery sub-module (FPBA)

The maximum number of sub-modules in an FPMA is four.
For installation instructions, see section Installing Flexi Power Module (FPMA) in the
Installing Flexi Multiradio BTS GSM/EDGE Optional Items document.
The FPMA is presented in the following figures.

Figure 1

DN0946895
Issue 02A

Power Module (FPMA)


Id:0900d805807fba9a
Confidential

13


Flexi Power Module (FPMA) and submodules (FPAA
and FPBA) description

Figure 2

Flexi Multiradio BTS GSM/EDGE Optional Items Description

FPMA: full configuration with two FPAAs and two FPBAs

For examples of how many FPMAs are required for common configurations, see section
Common configurations in Creating Stack, Wall and Pole Configurations for Flexi Multiradio BTS GSM/EDGE, Creating FCIA Configurations for Flexi Multiradio BTS
GSM/EDGE and Creating FCOA Configurations for Flexi Multiradio BTS GSM/EDGE.
The FPMA can support 1-phase and 3-phase AC input. The nominal input voltage is
200-240 V AC (the operating voltage range is 180 - 276 V AC). The maximum output
power from the FPMA is 4kW (with 4 FPAAs).
Flexi Power AC-DC sub-module (FPAA)
The main function of the FPAA is to provide the BTS with nominal 48 V DC power from
an AC supply. Maximum DC output power of one FPAA module is 1000 W. A nominal
48 V DC supply is intended for BTS internal use only (a nominal 48 V DC supply is not
intended for 3rd party equipment because they may require lower conducted emission
level than EN55022 Class A). The FPAA includes its own integrated self-controlled fan.
In case the fan fails, an alarm is generated and the FPAA has to be replaced (the fan
alone cannot be replaced).


!
Risk of thermal runaway of the battery, because temperature compensation of charging
voltage is not supported. Do not connect an external lead acid battery for longer backup
times to a nominal 48 V DC supply.
The FPAA unit remembers the main control switch position. If the FPAA power is
switched to Standby, the power remains OFF after input voltage interrupt.
The stand-by switch is used for switching the FPAA unit ON/Stand-by when AC input
voltage has been connected to the FPAA unit.
Flexi Power Battery sub-module (FPBA/B)
The Flexi Power Battery Sub-Module (FPBA/B) is a separate optional sub-module used
together with the FPAA.

14

Id:0900d805807fba9a
Confidential

DN0946895
Issue 02A


Flexi Multiradio BTS GSM/EDGE Optional Items Description

Flexi Power Module (FPMA) and submodules (FPAA
and FPBA) description

The FPBA/B provides short-term battery backup time when the AC power mains is down
on a Flexi BTS site. The FPBA is a lithium ion battery and the FPBB is a Lithium Ferrite
battery. The maximum DC output power from one FPBA/B module is 1000 W. The input

power for the BTS cannot exceed the maximum output power of the installed batteries.
Otherwise the batteries do not provide the BTS with the needed power during power
failure.
The power switch of the FPBA/B unit controls input power. Batteries can be drained by
the BTS if the power switch is set to OFF position.
The stand-by switch is used for switching the FPBA/B unit to ON/Stand-by when AC
input voltage has been connected to the FPBA/B unit.

g Do not install the FPBA and FPBB in parallel. If used in parallel, one of these two
battery types will discharge faster than the other causing an unbalance between the
batteries.
Lightning protection requirements




DN0946895
Issue 02A

+/- 2 kV, 1.2/50 µs pulse, Rs=(2 Ω + 10 Ω ) (line to ground, common)
+/- 1 kV, 1.2/50 µs pulse, Rs=2 Ω (line to line, differential)
+/- 6 kV, 1.2/50 µs pulse, Rs=2 Ω (each phase conductor to green-wire ground or
neutral conductor, neutral conductor and green-wire ground)

Id:0900d805807fba9a
Confidential

15



Flexi Multiradio BTS GSM/EDGE Optional Items Description

3.2

Flexi Power Module (FPMA) and sub-module (FPAA and
FPBA/B) interfaces
FPMA front panel connectors
The connectors on the FPMA front panel, their types and purposes are listed in the table
below.
Connector

Type

Purpose

Power supply in

Terminal block

AC main power supply in

Power supply out

2-wire DC cable 4 x multibeam

DC feed to the BTS

Grounding

2 x M5


Module grounding

Table 1

FPMA front panel connectors, types and purposes

FPAA front panel connectors
There is a stand-by switch on the front panel of the FPAA. The stand-by switch is used
for switching the FPAA unit ON/stand-by.
The connectors on the FPAA front panel, their types and purposes are listed in the table
below.
Connector

Type

Purpose

AC cable connector

Mate-N-Lock

AC input

DC connector

Multi-beam power supply
connector

DC output


Alarm connector

2 x RJ-45*

Alarms**

Operational state visual indi- tri-colour LED
cation

Table 2

FPAA state or alarm indication

FPAA front panel connectors, types and purposes

*for chaining
**Alarm 1 (AL01): AC input failure (alarm is sent when AC input voltage is missing or it
is out of range).
**Alarm 2 (AL02): maintenance needed (possible reasons are unit failure, cooling fan
failure, output power is low or over temperature shut down is ON).
FPBA/B front panel connectors
There is a stand-by switch on the front panel of the FPBA/B.
The connectors on the FPBA/B front panel, their types and purposes are listed in the
table below.
Connector

Type

Purpose


DC input/output connector

Multi-beam power supply
connector

DC input and output

Table 3

16

FPBA/B front panel connectors, types and purposes

Id:0900d805807fba97
Confidential

DN0946895
Issue 02A


Flexi Multiradio BTS GSM/EDGE Optional Items Description

Connector

Type

Purpose

Alarm connector


2 x RJ-45*

Alarms**

Operational state visual indication

tri-colour LED

FPBA state or alarm indication

Table 3

FPBA/B front panel connectors, types and purposes (Cont.)

*for chaining
**Alarm 2 (AL02): maintenance needed (possible reasons are unit failure, output power
is low or unit has reached end of it's life).
**Unit has an input for Alarm 1 (AL01) from FPAA unit (Alarm 1 is a trigger for battery
discharging).

DN0946895
Issue 02A

Id:0900d805807fba97
Confidential

17



Flexi Multiradio BTS GSM/EDGE Optional Items Description

3.3

Flexi Power Module (FPMA) dimensions and weight
The following table lists the dimensions and weight for Flexi Power Module (FPMA).
Property

FPMA

Height

133 mm/3 U
(5.2 in.)

Width

447 mm
(17.6 in.)

Depth without covers

422 mm
(16.6 in.)

Depth with covers

560 mm
(22.1 in.)


Weight (empty)

< 11 kg
(< 24.3 lbs)

Weight

28 kg

(fully equipped with one AC/DC
power module and batteries)

(61.9 lbs)

Table 4

18

Dimensions and weight of the FPMA

Id:0900d805807fba98
Confidential

DN0946895
Issue 02A


Flexi Multiradio BTS GSM/EDGE Optional Items Description

3.4


Flexi power sub-module (FPAA and FPBA/B) LED indications
FPAA LED indications
The FPAA LED indications are explained in the table below. Read the information on
LED indications thoroughly. A blinking red LED does not always require removing the
module.
Colour

Explanation

Yellow

Stand-by (AC connected)

Green

Normal operation

Red

Alarm or fault

Red, blinking

Unit operating with abnormal input voltage

Table 5

FPAA LED indications


See the following figure for the location of the FPAA LED.

LED

DN70350654

Figure 3

FPAA LED

FPBA/B LED indications
The FPBA/B LED indications are explained in the table below.
Colour

Explanation

Yellow

Stand-by (DC connected from FPAA)

Ggreen

Normal operation, battery OK

Green, blinking slowly

Charging

Green, blinking fast


Discharging

Blinking fast between green and yellow

Forced discharge mode

Red, blinking fast

Minor alarm

Red

Major alarm or fault

Table 6

FPBA/B LED indications

The LED's slow blinking frequency is 1 Hz (1 sec) and fast blinking frequency 2 Hz (0.5
sec).

DN0946895
Issue 02A

Id:0900d805807fba99
Confidential

19



Flexi Multiradio BTS GSM/EDGE Optional Items Description

See the following figure for the location of the FPBA/B LED.

Figure 4

20

FPBA/B LED

Id:0900d805807fba99
Confidential

DN0946895
Issue 02A


Flexi Multiradio BTS GSM/EDGE Optional Items Description

Flexi Power DC/DC Sub-Module (FPDA) description

4 Flexi Power DC/DC Sub-Module (FPDA)
description
4.1

Flexi Power DC/DC Module (FPDA) operation
Flexi Power DC/DC Module (FPDA) is an optional stand-alone 2 kW DC/DC module.
The FPDA converts nominal 24 V DC input voltage (normally negative grounded) 53-55
V DC output voltage. The 53-55 V DC is then distributed to BTS loads. When the BTS
power load is more than 2 kW, multiple FPDAs can be installed in parallel. When FPDAs

are used in parallel, a maximum of two DC cables can be installed together at each
output terminal.
Conducted emission level of the 53-55 V DC supply is according to the standard
EN55022 Class A. The 53-55 V DC supply is intended for BTS internal use only (the 5355 V DC supply is not intended for 3rd party equipment because they may require lower
conducted emission level than EN55022 Class A).

!
Risk of thermal runaway of the battery, because temperature compensation of charging
voltage is not supported. Do not connect an external lead acid battery for longer backup
times to the 53-55 V DC supply.
The FPDA includes its own integrated self-controlled fan. In case the fan fails, an alarm
is generated and the fan has to be replaced.
For installation instructions, see section Installing Flexi Power DC/DC Module 24V
FPDA in the Installing Flexi Multiradio BTS GSM/EDGE Optional Items document.
The FPDA is presented in the following figure.

DN70150502

Figure 5

DN0946895
Issue 02A

Flexi Power DC/DC Module (FPDA)

Id:0900d805806d9a9a
Confidential

21



Flexi Multiradio BTS GSM/EDGE Optional Items Description

4.2

Flexi Power DC/DC Module (FPDA) interfaces
There is a stand-by switch on the front panel of the FPDA.
The connectors on the FPDA front panel, their types and purposes are listed in the table
below.
Connector

Connector type

Purpose

Input connector

M10 bolts

DC input

Output connector

M10 bolts

DC output

Alarm connectors

2 x RJ-45*


Alarms**

Table 7

FPDA front panel connectors, connector types and purposes

*for chaining
**Alarm 1 (AL01): DC input failure (alarm is sent when DC input voltage is missing or it
is out of range).
**Alarm 2 (AL02): maintenance needed (possible reasons are unit failure, cooling fan
failure, output power is low or over temperature shut down is ON).
The FPDA front panel is presented in the following figure.

DC Input cabling

Alarm cabling

DC Output cabling

LED

GND
DN70141402

Figure 6

22

Front panel of the FPDA


Id:0900d805806d9a91
Confidential

DN0946895
Issue 02A


Flexi Multiradio BTS GSM/EDGE Optional Items Description

4.3

Flexi Power DC/DC Module (FPDA) dimensions and weight
The following table lists the dimensions and weight for the FPDA.
Property

Value

Height

90 mm (2U)
(3.5 in.)

Width

447 mm
(17.6 in.)

Depth without covers


422 mm
(16.6 in.)

Depth with covers

560 mm
(22.1 in.)

Weight

< 15 kg
(< 33.1 lbs)

Table 8

DN0946895
Issue 02A

Dimensions and weight of the FPDA

Id:0900d805806d9a94
Confidential

23


Flexi Multiradio BTS GSM/EDGE Optional Items Description

4.4


Flexi Power DC/DC Module (FPDA) LED indications
The FPDA has a tri-colour LED on the front panel to indicate the operational status of
the module and all fault conditions during operation. Read the information on LED indications thoroughly. A blinking red LED does not always require removing the module.
The LED indications of the FPDA are listed and explained in the table below.
Colour

Explanation

Green

Normal operation

Red

Alarm or fault

Yellow

Stand-by

Red, blinking

Abnormal input voltage

Table 9

24

FPDA LED indications


Id:0900d805806d9a97
Confidential

DN0946895
Issue 02A


Flexi Multiradio BTS GSM/EDGE Optional Items Description

Diplexer Unit (DU2A)

5 Diplexer Unit (DU2A)
5.1

5.1.1

Technical description of Dual Band Diplex Filter (DU2A)
unit
Function
The Dual Band Diplex Filter Unit (DU2A) either combines signals of different frequency
bands onto one antenna, or splits an antenna signal into different frequency bands. It
handles TX and RX signals from the GSM/EDGE 800/900 bands and the GSM/EDGE
1800/1900 bands.
For more information on Dual Band Diplex Filter (DU2A), see Nokia Siemens Networks
Antenna Systems Operating Documentation.

2

1
3


DN03418717

1

Dual band antenna

2

RX/TX GSM 1800/1900 band

3

RX/TX GSM 800/900 band

Figure 7

DU2A unit

Lightning protection
The centre pin of the DU2A unit antenna port is DC grounded. This connection prevents
a charge buildup on the antenna and protects th DU2A unit against lightning.

5.1.2

Operation
The DU2A unit operates on the following frequency bands:

DN0946895
Issue 02A


Id:0900d805806d9ab3
Confidential

25


×