BRITISH STANDARD
Fibre optic
interconnecting
devices and passive
components
performance
standard —
Part 021-2: Grade C/3 single-mode fibre
optic connectors for category C —
Controlled environment
ICS 33.180.20
12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$:
BS EN
61753-021-2:
2008
BS EN 61753-021-2:2008
National foreword
This British Standard is the UK implementation of EN 61753-021-2:2008. It is
identical to IEC 61753-021-2:2007. It supersedes BS EN 61753-021-2:2002
which is withdrawn.
The UK participation in its preparation was entrusted by Technical Committee
GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting
devices and passive components.
A list of organizations represented on this committee can be obtained on
request to its secretary.
This publication does not purport to include all the necessary provisions of a
contract. Users are responsible for its correct application.
Compliance with a British Standard cannot confer immunity from
legal obligations.
This British Standard was
published under the authority
of the Standards Policy and
Strategy Committee
on 30 May 2008
© BSI 2008
ISBN 978 0 580 55481 0
Amendments/corrigenda issued since publication
Date
Comments
EUROPEAN STANDARD
EN 61753-021-2
NORME EUROPÉENNE
March 2008
EUROPÄISCHE NORM
ICS 33.180.20
Supersedes EN 61753-021-2:2002
English version
Fibre optic interconnecting devices
and passive components performance standard Part 021-2: Grade C/3 single-mode fibre optic connectors
for category C Controlled environment
(IEC 61753-021-2:2007)
Norme de qualité de fonctionnement
des dispositifs d'interconnexion
et composants passifs à fibres optiques Partie 021-2: Connecteurs à fibres
optiques unimodales de classe C/3
pour la catégorie C Environnement contrôlé
(CEI 61753-021-2:2007)
Lichtwellenleiter Verbindungselemente
und passive Bauteile Betriebsverhalten Teil 021-2: LichtwellenleiterSteckverbinder der Stufe C/3
für Einmodenfasern für die Kategorie C Kontrollierte Umgebung
(IEC 61753-021-2:2007)
This European Standard was approved by CENELEC on 2008-03-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61753-021-2:2008 E
BS EN 61753-021-2:2008
–2–
Foreword
The text of document 86B/2602/FDIS, future edition 2 of IEC 61753-021-2, prepared by SC 86B, Fibre
optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as EN 61753-021-2 on 2008-03-01.
This European Standard supersedes EN 61753-021-2:2002.
EN 61753-021-2:2008 has been updated to reflect changes made to EN 61753-1:2007.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement
(dop)
2008-12-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow)
2011-03-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61753-021-2:2007 was approved by CENELEC as a European
Standard without any modification.
__________
–3–
BS EN 61753-021-2:2008
CONTENTS
1
Scope ...............................................................................................................................4
2
Normative references .......................................................................................................4
3
Terms and definitions .......................................................................................................5
4
Tests ................................................................................................................................6
5
Test report........................................................................................................................6
6
Reference components .....................................................................................................7
7
Performance requirements ...............................................................................................7
7.1
7.2
7.3
7.4
7.5
Dimensions .............................................................................................................7
Sample size, test sequencing and grouping .............................................................7
Endface geometry ...................................................................................................7
Performance criteria ................................................................................................7
Performance details ................................................................................................7
Annex A (normative) Sample size, test sequencing and grouping requirements ................... 13
Annex ZA (normative) Normative references to international publications with their
corresponding European publications ................................................................................... 14
Figure 1 – Pigtail assembly .....................................................................................................6
www.bzfxw.com
Figure 2 – Jumper cable assembly..........................................................................................6
Table 1 – Performance levels .................................................................................................7
Table 2 – Performance details ................................................................................................8
Table A.1 – Sample size, test sequencing and grouping requirements .................................. 13
BS EN 61753-021-2:2008
–4–
FIBRE OPTIC INTERCONNECTING DEVICES
AND PASSIVE COMPONENTS PERFORMANCE STANDARD –
Part 021-2: Grade C/3 single-mode fibre optic connectors for category C –
Controlled environment
1
Scope
This part of IEC 61753 defines C/3 minimum initial test and measurement requirements and
severities which a single-mode connector/cable assembly must satisfy in order to be
categorized as meeting the IEC standard category C (controlled environment), as defined in
Clause A.2 of IEC 61753-1.
2
Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60793-2-50, Optical fibres – Part 2-50: Product specifications – Sectional specification for
class B single-mode fibres
www.bzfxw.com
IEC 61300-2-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)
IEC 61300-2-2, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-2: Tests – Mating durability
IEC 61300-2-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-4: Tests – Fibre/cable retention
IEC 61300-2-6, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-6: Tests – Tensile strength of coupling mechanism
IEC 61300-2-12, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-12: Tests – Impact
IEC 61300-2-17, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-17: Tests – Cold
IEC 61300-2-18, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-18: Tests – Dry heat – High temperature endurance
IEC 61300-2-19, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-19: Tests – Damp heat (steady state)
IEC 61300-2-22, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-22: Tests – Change of temperature
IEC 61300-2-42, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-42: Tests – Static side load for connectors
–5–
BS EN 61753-021-2:2008
IEC 61300-2-44, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-44: Tests – Flexing of the strain relief of fibre optic
devices
IEC 61300-3-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-1: Examinations and measurements – Visual examination
IEC 61300-3-3, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-3: Examinations and measurements – Active monitoring of
changes in attenuation and return loss
IEC 61300-3-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-4: Examinations and measurements – Attenuation
IEC 61300-3-6, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-6: Examinations and measurements – Return loss
IEC 61300-3-28, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 3-28: Examinations and measurements – Transient loss
IEC 61300-3-34, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 3-34: Examinations and measurements – Attenuation of
random mated connectors
IEC 61753-1:2007 Fibre optic interconnecting devices and passive components performance
standard – Part 1: General and guidance for performance standards
www.bzfxw.com
IEC 61754 (all parts), Fibre optic connector interfaces
IEC 61755 (all parts), Fibre optic connector optical interfaces
IEC 61755-3 (all parts) Fibre optic connector optical interfaces – Part 3: Optical interface
ISO 11801, Information technology – Generic cabling for customer premises
3
Terms and definitions
For the purposes of this document, the following definitions apply.
3.1
change in attenuation
peak-to-peak variation
3.2
sample
complete set of connector components required to provide demountable coupling between
one or more pairs of optical fibres
3.3
pigtail assembly
two connector plugs mated with an adapter with unterminated leads, as shown in Figure 1.
NOTE Each of the unterminated leads should be at least 3 m long so that the splices may be located outside of
the environmental test chamber.
BS EN 61753-021-2:2008
–6–
Adapter
Connector
IEC 1967/07
Figure 1 – Pigtail assembly
3.4
jumper cable assembly
jumper cable terminated with plugs on each end connected with adapters to two additional
connector plugs with unterminated leads on either end, as shown in Figure 2. The jumper
cable should be 5 m ± 0,5 m. Each of the unterminated leads should be long enough so that
the splices may be located outside of the environmental test chamber.
Adapter
Adapter
Connector
Unterminated
lead
Cable
Unterminated
lead
www.bzfxw.com
IEC 2315/07
Figure 2 – Jumper cable assembly
4
Tests
All test methods are in accordance with the relevant parts of IEC 61300 as defined in 7.4 and
7.5.
The connectors under test shall be terminated onto single-mode fibre per type B1.1 or B1.3 of
IEC 60793-2-50, in either secondary coated or cable format. The connector interface standard
shall meet the dimensions of IEC 61754 and the connector optical interface standard shall
meet the relevant requirements of IEC 61755.
The optical connector requirements shall be met in order to be in accordance with IS0 11801.
Each test defines the number of samples to be evaluated. The sample set used for the first
test is to be composed of randomly selected and previously unstressed new samples.
The optical criteria for each test shall be as defined in 7.4.
5
Test report
Fully documented test reports and supporting evidence shall be prepared and available for
inspection as evidence that the tests have been carried out and the results are satisfactory.
–7–
6
BS EN 61753-021-2:2008
Reference components
No reference components are required to perform the tests in this standard.
7
Performance requirements
7.1
Dimensions
Dimensions shall comply with the appropriate IEC interface standard as defined in IEC 61754.
7.2
Sample size, test sequencing and grouping
For the purposes of this standard, a sample is composed of pigtail assemblies and jumper
cable assemblies (see Clause 3). The sample sizes to be used for the tests shall be as
defined in Annex A. There is no defined sequence or grouping in which the tests shall be run.
Samples for the first test (attenuation) are to be randomly selected and randomly mated new
products. Samples for the second test (return loss) are the same plugs selected and mated for the
first test. Samples for subsequent tests may be randomly selected and randomly mated new
products or the same plugs.
7.3
Endface geometry
The connector endface shall comply with the endface geometry requirements of the applicable
IEC optical interface standard as defined in 61755-3. Compliance with the appropriate optical
interface standard shall be confirmed on all samples before the start of testing and after all of
the tests have been completed. Non-compliance with the endface geometry requirements of
the applicable optical interface standard on any connector tested results in a failure of this
performance standard.
7.4
www.bzfxw.com
Performance criteria
The optical performance levels shall meet the requirements of Grade C/3 as defined in
Table A.12 of IEC 61753-1. See Table.1
Table 1 – Performance levels
Performance
level
Test name
Attenuation
IEC 61300-3-34
C/3
Return loss
IEC 61300-3-6
Initial
≤0,25 dB mean
≤0,50 dB max. for ≥97 % of
samples
≥35 dB
Monitoring change in
attenuation and in return
loss (multiple path
IEC 61300-3-3)
7.5
During and after test
Performance details
Performance details are specified in Table 2.
Return loss ≥35 dB during and
after test
Maximum variation ≤0,2 dB during
and after test for pigtails
Maximum variation ≤0,5 dB
during and ≤0,4 dB after test for
patchcords
BS EN 61753-021-2:2008
–8–
Table 2 – Performance details
No
1
Test
Attenuation
(Method C)
Requirements
Details
Grade C performance level:
Mean ≤ 0,25
Maximum = 0,50 dB
IEC 61300-3-4
Test wavelengths:
1 310 nm ± 30 nm and
1 550 nm ± 30 nm (launch condition
S4 and S5)
Launch mode conditions: only the fundamental
mode shall propagate at the connector interface
and at the detector.
Device under test (DUT) type 5, Insertion method
(C)
Source characteristics reference to
IEC 61300-3-4 (attenuation)
Specimen shall be optically functioning.
Preconditioning procedure: clean plug and
adapter according to manufacturer’s instructions.
2
Return loss
Grade 3 performance level:
Minimum > 35 dB
IEC 61300-3-6 Method branching devices
Test wavelengths:
1 310 nm ± 20 nm and 1 550 nm
± 20 nm
Source stability: ±0,20 dB over the measuring
period or at least 1 h
Launch fibre length: L > 2 m
Detector linearity: within 5 % of the power levels
to be measured
Directivity: >65 dB
Specimen shall be optically functioning.
Preconditioning procedure: clean plug and
adapter according to manufacturer’s instructions.
Alternative method: IEC 61300-3-6 Method OTDR
Launch fibre length: L1 ≥ 500 m, L2 ≥ 6 m,
L3 ≥ 6 m
www.bzfxw.com
Pulse duration: ≤10 ns
Specimen shall be optically functioning.
Preconditioning procedure: clean plug and
adapter according to manufacturer’s instructions.
3
Vibration
(sinusoidal)
Attenuation:
All attenuation measurements shall
meet the criteria specified in 7.4.
Return loss:
All return loss measurements shall
meet the criteria specified in 7.4.
Test wavelengths:
1 550 nm ± 20 nm
IEC 61300-2-1
Frequency range: 10 Hz to 55 Hz
Change in frequency: 1 oct/min
Endurance duration per axis: 0,5 h
Number of axes: three orthogonal
Number of sweeps per axis: 15
Vibration amplitude: 0,75 mm
Sampling rate: before, during and after each axis.
The measurement interval during the test shall be
< 2 ms and transient monitoring shall be
performed according to IEC 61300-3-28.
Sampling rate note: Attenuation and return loss
decrease is the difference between any
measurement and the initial measurement, and
applies to all measurements. Maximum
attenuation and return loss criteria apply to all
measurements.
Method of mounting: an adapter shall be mounted
rigidly to the mounting fixture.
Specimen shall be optically functioning.
Preconditioning procedure: clean plug and
adapter according to manufacturer’s instructions.
The connector samples shall not be uncoupled or
cleaned anytime during the test.
BS EN 61753-021-2:2008
–9–
Table 2 (continued)
No
4
Test
Cold
Requirements
Details
Attenuation:
All attenuation measurements shall
meet the criteria specified in 7.4.
IEC 61300-2-17
Return loss:
All return loss measurements shall
meet the criteria specified in 7.4.
Duration of exposure: 96 h
Test wavelengths:
1 550 nm ± 20 nm
Sampling rate: before and after test and at a
maximum interval of 1 h during the test.
Temperature: –10 °C ± 2 °C
Length of the cable on each side of the connector
inside the chamber: 1,5 m minimum
Preconditioning procedure: before test,
specimens shall be maintained in room
temperature condition for 2 h. Clean plug and
adapter according to manufacturer’s instructions.
Recovery procedure: after test, specimens shall
be maintained in room temperature condition for
2 h.
The connector samples shall not be uncoupled or
cleaned anytime during the test.
5
Dry heat high
temperature
endurance
Attenuation:
All attenuation measurements shall
meet the criteria specified in 7.4.
IEC 61300-2-18
Return loss:
All return loss measurements shall
meet the criteria specified in 7.4.
Duration of exposure: 96 h
Test wavelengths:
1 550 nm ± 20 nm
Sampling rate: before and after test and at a
maximum interval of 1 h during the test
Temperature: +60 °C ± 2 °C
Length of the cable on each side of the connector
inside the chamber:1,5 m minimum
www.bzfxw.com
Preconditioning procedure: before test,
specimens shall be maintained in room
temperature condition for 2 h. Clean plug and
adapter according to manufacturer’s instructions.
Recovery procedure: after test, specimens shall
be maintained in room temperature condition for
2 h.
The connector samples shall not be uncoupled or
cleaned anytime during the test.
6
Damp heat
(steady
state)
Attenuation:
All attenuation measurements shall
meet the criteria specified in 7.4.
IEC 61300-2-19
Return Loss:
All return loss measurements shall
meet the criteria specified in 7.4.
Relative humidity: 93 % – 3 %
Test wavelengths:
1 550 nm ± 20 nm
Temperature: +40 °C ± 2 °C
+2
Duration of exposure: 96 h
Length of the cable on each side of the connector
inside the chamber: 1,5 m minimum
Sampling rate: before and after test and at a
maximum interval of 1 h during the test
Preconditioning procedure: before test,
specimens shall be maintained in room
temperature condition for 2 h. Clean plug and
adapter according to manufacturer’s instructions.
Recovery procedure: after test, specimens shall
be maintained in room temperature condition for
2 h.
The connector samples shall not be uncoupled or
cleaned anytime during the test.
BS EN 61753-021-2:2008
– 10 –
Table 2 (continued)
No
7
Test
Change of
temperature
Requirements
Details
Attenuation:
All attenuation measurements shall
meet the criteria specified in 7.4.
IEC 61300-2-22, Test Nb
Return loss:
All return loss measurements shall
meet the criteria specified in 7.4.
Low temperature dwell: –10 °C ± 2 °C
High temperature dwell: +60 °C ± 2 °C
Duration at each dwell temperature: 1 h
Ramp time = 1 °C/minute
Test wavelengths:
1 550 nm ± 20 nm
Number of cycles: 5
Length of the cable on each side of the connector
inside the chamber: 1,5 m minimum
Specimen shall be optically functioning.
Sampling rate: initially at room ambient, after
1/2 h during each dwell (measurements to be
completed during dwell) and at the end of the test
at room ambient.
Preconditioning procedure: before test,
specimens shall be maintained in room
temperature condition for 2 h.
Recovery procedure: after test, specimens shall
be maintained in room temperature condition for
2 h.
The connector samples shall not be uncoupled or
cleaned anytime during the test.
8
Flexing of
the strain
relief of fibre
optic devices
www.bzfxw.com
Attenuation:
All attenuation measurements shall
meet the criteria specified in 7.4.
Return loss:
All return loss measurements shall
meet the criteria specified in 7.4.
IEC 61300-2-44
Magnitude of the tensile load: 2 N for connectors
with reinforced cable
Cycle: 0° to +90° to 0° to –90° to 0° (continuous
with reversing at ±90°)
Test wavelengths:
1 310 nm ± 20 nm and 1 550 nm ±
20 nm
Number of cycles: 100
NOTE This test does not apply to
connectors without reinforced cable.
Point of application of tensile load: 220 mm 280 mm from cable entrance to plug
Rate of application of the tensile load: 1 N/s for
reinforced cable
Sampling rate: initially, during and at the end of
the test. Measurement interval during the test
shall be <2 msec and transient monitoring shall
be performed according to IEC 61300-3-28.
Method of mounting: an adapter shall be mounted
rigidly to the test fixture.
Preconditioning procedure: clean plug and
adapter according to manufacturer’s instructions.
The connector samples shall not be uncoupled or
cleaned at anytime during the test.
BS EN 61753-021-2:2008
– 11 –
Table 2 (continued)
No
9
Test
Fibre cable
retention
Requirements
Details
Attenuation:
All attenuation measurements shall
meet the criteria specified in 7.4.
Return loss:
All return loss measurements shall
meet the criteria specified in 7.4.
Test wavelengths:
1 550 nm ± 20 nm
IEC 61300-2-4
Magnitude and rate of application of the load for
reinforced cables: 50 N ± 2 N at 5 N/s
Duration for reinforced cables: 120 s
Magnitude and rate of application of the load for
secondary coated fibres: 5,0 N ± 0,5 N at 5 N/s
Duration for buffered fibres: 60 s
Magnitude and rate of application of the load for
primary coated fibres: 2,0 N ± 0,5 N at 5 N/s
Duration for buffered fibres: 60 s
Point of application of tensile load: 0,3 m from the
end face of the connector
Sampling rate: Initially and after the load has
reached its maximum level and been maintained
for a minimum of 30 s
Specimen shall be optically functioning.
Preconditioning procedure: clean plug and
adapter according to manufacturer’s instructions.
10
Impact
Attenuation:
All attenuation measurements shall
meet the criteria specified in 7.4.
Number of drops: 5 for each plug
Drop height: 1,5 m
www.bzfxw.com
Return loss:
All return loss measurements shall
meet the criteria specified in 7.4.
Test wavelengths:
1 550 nm ± 20 nm
IEC 61300-2-12 Method A
Sampling rate: Initially and after the last drop
Specimen shall be unmated during drop cycles.
Preconditioning procedure: clean plug and
adapter according to manufacturer’s instructions.
Place a dust cap over the ferrule to protect the
fibre endface.
Recovery procedure: the connector may be
cleaned after each drop before measurement.
11
Tensile
strength of
coupling
mechanism
Attenuation:
All attenuation measurements shall
meet the criteria specified in 7.4.
Return loss:
All return loss measurements shall
meet the criteria specified in 7.4.
Test wavelengths:
1 550 nm ± 20 nm
IEC 61300-2-6
Magnitude and rate of application of the load:
40 N ± 1 N at 2 N/s
Duration: 60 s
Sampling rate: Initially and after the load has
reached its maximum level and been maintained
for a minimum of 30 s
Specimen shall be optically functioning.
Preconditioning procedure: clean plug and
adapter according to manufacturer’s instructions.
BS EN 61753-021-2:2008
– 12 –
Table 2 (continued)
No
12
Test
Static side
load
Requirements
Details
Attenuation:
All attenuation measurements shall
meet the criteria specified in 7.4.
IEC 61300-2-42
Return loss:
All return loss measurements shall
meet the criteria specified in 7.4.
Duration for reinforced cables: 1 h
Test wavelengths:
1 550 nm ± 20 nm
Magnitude of the load for reinforced cables: 1 N
Magnitude of the load for buffered fibres: 0,2 N
Duration for buffered fibres: 5 min
Static side load shall be applied in two mutually
perpendicular directions.
Sampling rate: Initially and 3 min maximum
intervals
Specimen shall be optically functioning.
Preconditioning procedure: clean plug and
adapter according to manufacturer’s instructions.
13
Mating
durability
Attenuation:
All attenuation measurements shall
meet the criteria specified in 7.4.
Return loss:
All return loss measurements shall
meet the criteria specified in 7.4.
IEC 61300-2-2
Coupling mechanism to be cycled:
plug-adapter
Cycling rate: not less than 3 s between each
engagement and separation
Test wavelengths:
1 550 nm ± 20 nm
Number of cycles: 500 minimum
In the event that the attenuation
increases above the allowable limit,
the connector may be cleaned as
necessary but not more than 25 times
during the course of the test. (The
measurements at which the cleaning
takes place shall be discounted from
the test results).
Preconditioning procedure: clean plug and
adapter according to manufacturer’s instructions.
The connector plugs and adapters
shall be inspected for damage that
might impair the performance. This
inspection shall include:
IEC 61300-3-1
Specimen shall be optically functioning.
www.bzfxw.com
14
Visual
inspection
−
distortion of housing parts, as
indicated by difficulty in
insertion, improper snap-fits,
etc.;
−
distortion of ferrules and
sleeves, as indicated by change
in mating force, changes in
endface geometry, etc.;
−
housing cracks;
−
presence of debris, shavings,
etc.;
−
corrosion or residue;
−
ferrule end-face cracks chips or
scratches;
−
other potentially service-affecting
damage.
Recovery procedure: the mechanical and optical
alignment parts of the specimen may be cleaned
according to manufacturer’s instructions up to 2
times after the final mating cycle.
BS EN 61753-021-2:2008
– 13 –
Annex A
(normative)
Sample size, test sequencing and grouping requirements
The tests in Table A.1 are intended to be performed individually on products selected as
defined in 7.2, although products from a previous test may be used if desired. The tests may
also be performed in any order providing the product is selected as defined.
Table A.1 – Sample size, test sequencing and grouping requirements
Test
Sample size
Test No.
Source
Pigtail
Assembly
Jumper Cable
Assembly
1
Attenuation (random mate)
20
5
New
2
Return loss (random mate)
20
5
Test 1
3
Vibration
5
--
Test 2
4
Cold
5
5
Test 2
5
Dry heat - high temperature endurance
5
5
Test 2
6
Damp heat (steady state)
5
5
Test 2
7
Change of temperature
5
5
Test 2
8
Flexing of the strain relief of fibre optic
devices
5
5
Test 2
9
Fibre cable retention
5
--
Test 2
10
Impact
5
--
Test 2
11
Tensile strength of coupling
5
--
Test 2
12
Static side load
5
--
Test 2
13
Mating durability
5
--
Test 2
14
Visual Inspection
5
--
All
www.bzfxw.com
___________
BS EN 61753-021-2:2008
– 14 –
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication
Year
Title
EN/HD
Year
Optical fibres Part 2-50: Product specifications - Sectional
specification for class B single-mode fibres
EN 60793-2-50
+ corr. July
2004
2004
2)
IEC 60793-2-50
-
1)
IEC 61300-2-1
-
1)
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-1: Tests - Vibration (sinusoidal)
EN 61300-2-1
2003
2)
IEC 61300-2-2
-
1)
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-2: Tests - Mating durability
EN 61300-2-2
2003
2)
IEC 61300-2-4
-
1)
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-4: Tests - Fibre/cable retention
EN 61300-2-4
1997
2)
IEC 61300-2-6
-
1)
Fibre optic interconnecting devices and
EN 61300-2-6
passive components - Basic test and
measurement procedures Part 2-6: Tests - Tensile strength of coupling
mechanism
1997
2)
IEC 61300-2-12
-
1)
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-12: Tests - Impact
EN 61300-2-12
2005
2)
IEC 61300-2-17
-
1)
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-17: Tests - Cold
EN 61300-2-17
2003
2)
IEC 61300-2-18
-
1)
Fibre optic interconnecting devices and
EN 61300-2-18
passive components - Basic test and
measurement procedures Part 2-18: Tests - Dry heat - High temperature
endurance
2005
2)
IEC 61300-2-19
-
1)
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-19: Tests - Damp heat (steady state)
2005
2)
1)
2)
Undated reference.
Valid edition at date of issue.
www.bzfxw.com
EN 61300-2-19
– 15 –
Publication
IEC 61300-2-22
Year
1)
-
IEC 61300-2-42
-
IEC 61300-2-44
BS EN 61753-021-2:2008
Title
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-22: Tests - Change of temperature
EN/HD
EN 61300-2-22
Year
2)
2007
1)
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-42: Tests - Static side load for
connectors
EN 61300-2-42
2005
2)
-
1)
Fibre optic interconnecting devices and
EN 61300-2-44
passive components - Basic test and
measurement procedures Part 2-44: Tests - Flexing of the strain relief of
fibre optic devices
2005
2)
IEC 61300-3-1
-
1)
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 3-1: Examinations and measurements Visual examination
EN 61300-3-1
2005
2)
IEC 61300-3-3
-
1)
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 3-3: Examinations and measurements Active monitoring of changes in attenuation
and return loss
EN 61300-3-3
2003
2)
IEC 61300-3-4
-
1)
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 3-4: Examinations and measurements Attenuation
EN 61300-3-4
2001
2)
IEC 61300-3-6
-
1)
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 3-6: Examinations and measurements Return loss
EN 61300-3-6
2003
2)
IEC 61300-3-28
-
1)
Fibre optic interconnecting devices and
EN 61300-3-28
passive components - Basic test and
measurement procedures Part 3-28: Examinations and measurements Transient loss
2002
2)
IEC 61300-3-34
-
1)
Fibre optic interconnecting devices and
EN 61300-3-34
passive components - Basic test and
measurement procedures Part 3-34: Examinations and measurements Attenuation of random mated connectors
2002
2)
IEC 61753-1
2007
Fibre optic interconnecting devices and
EN 61753-1
passive components performance standard Part 1: General and guidance for performance
standards
2007
IEC 61754
(mod)
Series Fibre optic connector interfaces
EN 61754
Series
IEC 61755
(mod)
Series Fibre optic connector optical interfaces
EN 61755
Series
IEC 61755-3
(mod)
Series Fibre optic connector optical interfaces Part 3: Optical interface
EN 61755-3
Series
www.bzfxw.com
BS EN 61753-021-2:2008
Publication
ISO/IEC 11801
Year
1)
-
– 16 –
Title
Information technology - Generic cabling for
customer premises
EN/HD
-
Year
-
www.bzfxw.com
www.bzfxw.com
blank
BS EN
61753-021-2:
2008
BSI — British Standards Institution
BSI is the independent national body responsible for preparing
British Standards. It presents the UK view on standards in Europe and at the
international level. It is incorporated by Royal Charter.
Revisions
British Standards are updated by amendment or revision. Users of
British Standards should make sure that they possess the latest amendments or
editions.
It is the constant aim of BSI to improve the quality of our products and services.
We would be grateful if anyone finding an inaccuracy or ambiguity while using
this British Standard would inform the Secretary of the technical committee
responsible, the identity of which can be found on the inside front cover.
Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.
BSI offers members an individual updating service called PLUS which ensures
that subscribers automatically receive the latest editions of standards.
Buying standards
Orders for all BSI, international and foreign standards publications should be
addressed to Customer Services. Tel: +44 (0)20 8996 9001.
Fax: +44 (0)20 8996 7001. Email: Standards are also
available from the BSI website at .
In response to orders for international standards, it is BSI policy to supply the
BSI implementation of those that have been published as British Standards,
unless otherwise requested.
Information on standards
www.bzfxw.com
BSI provides a wide range of information on national, European and
international standards through its Library and its Technical Help to Exporters
Service. Various BSI electronic information services are also available which give
details on all its products and services. Contact the Information Centre.
Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email:
Subscribing members of BSI are kept up to date with standards developments
and receive substantial discounts on the purchase price of standards. For details
of these and other benefits contact Membership Administration.
Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001.
Email:
Information regarding online access to British Standards via British Standards
Online can be found at />Further information about BSI is available on the BSI website at
.
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies. Except as
permitted under the Copyright, Designs and Patents Act 1988 no extract may be
reproduced, stored in a retrieval system or transmitted in any form or by any
means – electronic, photocopying, recording or otherwise – without prior written
permission from BSI.
BSI
389 Chiswick High Road
London
W4 4AL
This does not preclude the free use, in the course of implementing the standard,
of necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any other purpose than implementation then the prior
written permission of BSI must be obtained.
Details and advice can be obtained from the Copyright & Licensing Manager.
Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553.