BRITISH STANDARD
Lamp controlgear —
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
Part 2-4: Particular requirements for
d.c. supplied electronic ballasts for
general lighting
The European Standard EN 61347-2-4:2001 has the status of a
British Standard
ICS 29.140.99
NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW
BS EN
61347-2-4:2001
IEC
61347-2-4:2000
BS EN 61347-2-4:2001
National foreword
This British Standard is the official English language version of
EN 61347-2-4:2001. It is identical with IEC 61347-2-4:2000. Together with
BS EN 61347-1, -2-5, -2-6 and -2-7:2001 it supersedes Section Three of
BS EN 60924:1991 + A1:1994 which will be withdrawn on 1 November 2003.
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
The UK participation in its preparation was entrusted by Technical Committee
CPL/34, Lamps and related equipment, to Subcommittee CPL/34/3, Auxiliaries
for lamps, which has the responsibility to:
—
aid enquirers to understand the text;
—
present to the responsible international/European committee any
enquiries on the interpretation, or proposals for change, and keep the
UK interests informed;
—
monitor related international and European developments and
promulgate them in the UK.
A list of organizations represented on this subcommittee can be obtained on
request to its secretary.
From 1 January 1997, all IEC publications have the number 60000 added to
the old number. For instance, IEC 27-1 has been renumbered as IEC 60027-1.
For a period of time during the change over from one numbering system to the
other, publications may contain identifiers from both systems.
Cross-references
Attention is drawn to the fact that CEN and CENELEC Standards normally
include an annex which lists normative references to international
publications with their corresponding European publications. The British
Standards which implement these international or European publications may
be found in the BSI Standards Catalogue under the section entitled
“International Standards Correspondence Index”, or by using the “Find”
facility of the BSI Standards Electronic Catalogue.
A British Standard does not purport to include all the necessary provisions of
a contract. Users of British Standards are responsible for their correct
application.
Compliance with a British Standard does not of itself confer immunity
from legal obligations.
This British Standard, having
been prepared under the
direction of the
Electrotechnical Sector
Committee, was published
under the authority of the
Standards Committee and
comes into effect on
15 May 2001
Summary of pages
This document comprises a front cover, an inside front cover, the EN title page,
pages 2 to 11 and a back cover.
The BSI copyright date displayed in this document indicates when the
document was last issued.
Amendments issued since publication
Amd. No.
© BSI 05-2001
ISBN 0 580 37423 8
Date
Comments
EN 61347-2-4
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2001
ICS 29.140.99
Partly supersedes EN 60924:1991 + A1:1994
English version
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
Lamp controlgear
Part 2-4: Particular requirements for d.c. supplied electronic ballasts
for general lighting
(IEC 61347-2-4:2000)
Appareillages de lampes
Partie 2-4: Prescriptions particulières pour
les ballasts électroniques alimentés en
courant continu pour l'éclairage général
(CEI 61347-2-4:2000)
Geräte für Lampen
Teil 2-4: Besondere Anforderungen an
gleichstromversorgte elektronische
Vorschaltgeräte für die
Allgemeinbeleuchtung
(IEC 61347-2-4:2000)
This European Standard was approved by CENELEC on 2000-11-01. CENELEC members are bound
to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway,
Portugal, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61347-2-4:2001 E
Page 2
EN 61347−2−4:2001
Foreword
The text of document 34C/501/FDIS, future edition 1 of IEC 61347-2-4, prepared by SC 34C,
Auxiliaries for lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IECCENELEC parallel vote and was approved by CENELEC as EN 61347-2-4 on 2000-11-01.
This European Standard, together with EN 61347-1, supersedes section three of EN 60924:1991 +
A1:1994.
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement
(dop)
2001-08-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow)
2003-11-01
This standard shall be used in conjunction with EN 61347-1:2001.
NOTE In this standard, the following print types are used:
- requirements : in roman type;
- test specifications: in italic type;
- notes: in smaller roman type.
Annexes designated "normative" are part of the body of the standard.
In this standard, annexes A to H and ZA are normative.
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61347-2-4:2000 was approved by CENELEC as a
European Standard without any modification.
__________
Page 3
EN 61347−2−4:2001
CONTENTS
Page
INTRODUCTION ................................................................................................................................................ 4
Clause
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
1
Scope ........................................................................................................................................................ 5
2
Normative references .................................................................................................................................. 5
3
Definitions .................................................................................................................................................. 5
4
General requirements ................................................................................................................................. 5
5
General notes on tests ................................................................................................................................ 5
6
Classification.............................................................................................................................................. 5
7
Marking ...................................................................................................................................................... 6
7.1
Mandatory markings ......................................................................................................................... 6
7.2
Information to be provided, if applicable ............................................................................................ 6
8
Protection against accidental contact with live parts ..................................................................................... 6
9
Terminals ................................................................................................................................................... 6
10
Provisions for earthing ................................................................................................................................ 6
11
Moisture resistance and insulation ............................................................................................................... 6
12
Electric strength ......................................................................................................................................... 6
13
Thermal endurance test for windings............................................................................................................ 6
14
Pulse voltages ............................................................................................................................................ 7
15
Abnormal conditions ................................................................................................................................... 7
15.1
Removal of lamp(s) .......................................................................................................................... 7
15.2
Lamp fails to start (cathodes intact electrically) ................................................................................. 7
15.3
Polarity reversal............................................................................................................................... 8
16
Fault conditions .......................................................................................................................................... 8
17
Construction ............................................................................................................................................... 8
18
Creepage distances and clearances ............................................................................................................ 8
19
Screws, current-carrying parts and connections............................................................................................ 8
20
Resistance to heat, fire and tracking ............................................................................................................ 8
21
Resistance to corrosion............................................................................................................................... 8
Annex A (normative) Test to establish whether a conductive part is a live part
which may cause an electric shock...................................................................................................................... 9
Annex B (normative) Particular requirements for thermally protected lamp controlgear .......................................... 9
Annex C (normative) Particular requirements for electronic lamp controlgear with means
of protection against overheating ........................................................................................................................ 9
Annex D (normative) Requirements for carrying out the heating tests of thermally
protected lamp controlgear ................................................................................................................................. 9
Annex E (normative) Use of constant S other than 4 500 in t w tests ..................................................................... 9
Annex F (normative) Draught-proof enclosure ................................................................................................... 10
Annex G (normative) Explanation of the derivation of the values of pulse voltages .............................................. 10
Annex H (normative) Tests .............................................................................................................................. 10
Annex ZA (normative) Normative references to international publications with their corresponding European
publications ..................................................................................................................................................... 11
Table 1 – Pulse voltages .................................................................................................................................. 15
ã BSI 05-2001
Page 4
EN 61347−2−4:2001
INTRODUCTION
This first edition of IEC 61347-2-4, published in conjunction with IEC 61347-1, represents an
editorial review of section three of IEC 60924. The formatting into separately published parts
provides for ease of future amendments and revisions. Additional requirements will be added
as and when a need for them is recognized.
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
This standard, and the parts which make up IEC 61347-2, in referring to any of the clauses of
IEC 61347-1, specify the extent to which such a clause is applicable and the order in which the
tests are to be performed; they also include additional requirements, as necessary. All parts
which make up IEC 61347-2 are self-contained and, therefore, do not include references to
each other.
Where the requirements of any of the clauses of IEC 61347-1 are referred to in this standard
by the phrase “The requirements of clause n of IEC 61347-1 apply”, this phrase is interpreted
as meaning that all requirements of the clause in question of part 1 apply, except any which are
clearly inapplicable to the specific type of lamp controlgear covered by this particular part of
IEC 61347-2.
ã BSI 05-2001
Page 5
EN 61347−2−4:2001
LAMP CONTROLGEAR –
Part 2-4: Particular requirements for d.c. supplied electronic
ballasts for general lighting
1
Scope
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
This part of IEC 61347 specifies particular safety requirements for d.c. supplied electronic
ballasts intended for operation from transient and surge-free power sources, operated directly
from batteries without charging equipment as used in leisure equipment, for example,
caravans, etc.
Performance requirements are the subject of IEC 60925.
2
Normative references
For the purpose of this part of IEC 61347, the normative references given in clause 2 of
IEC 61347-1 which are mentioned in this standard apply, together with the following normative
references.
IEC 61347-1, Lamp controlgear – Part 1: General and safety requirements
IEC 60925, D.C. supplied electronic ballasts for tubular fluorescent lamps – Performance
requirements
3
Definitions
For the purpose of this part of IEC 61347, the definitions of clause 3 of IEC 61347-1 apply.
4
General requirements
The requirements of clause 4 of IEC 61347-1 apply.
5
General notes on tests
The requirements of clause 5 of IEC 61347-1 apply.
6
Classification
The requirements of clause 6 of IEC 61347-1 do not apply.
ã BSI 05-2001
Page 6
EN 61347−2−4:2001
7
7.1
Marking
Mandatory markings
In accordance with the requirements of 7.2 of IEC 61347-1, ballasts shall be clearly and
durably marked with the following mandatory markings:
–
items a), b), e), f), k) and l) of 7.1 of IEC 61347-1, together with
–
the open-circuit voltage (for warning only, not to be tested).
7.2
Information to be provided, if applicable
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
In addition to the above mandatory markings, the following information, if applicable, shall be
given either on the ballast, or be made available in the manufacturer’s catalogue or similar:
–
items h), j), n) and i) of 7.1 of IEC 61347-1, together with
–
whether the ballast is proof against supply voltage polarity;
–
design voltage;
–
that the ballast is for general use only.
8
Protection against accidental contact with live parts
The requirements of clause 10 of IEC 61347-1 apply.
9
Terminals
The requirements of clause 8 of IEC 61347-1 apply.
10 Provisions for earthing
The requirements of clause 9 of IEC 61347-1 apply.
11 Moisture resistance and insulation
The requirements of clause 11 of IEC 61347-1 apply, with the exception of the 7 M9 insulation
resistance requirement for reinforced insulation.
12 Electric strength
The requirements of clause 12 of IEC 61347-1 apply.
13 Thermal endurance test for windings
The requirements of clause 13 of IEC 61347-1 are not applicable.
ã BSI 05-2001
Page 7
EN 61347−2−4:2001
14 Pulse voltages
The ballast shall withstand without failure any pulses caused by switching other equipment on
the same circuit.
Compliance is checked by operating the ballast at the maximum voltage of the rated voltage
range in association with the appropriate number of lamps and in an ambient temperature of
25 °C. The ballast shall withstand without failure the number of pulse voltages specified in
table 1, superimposed with the same polarity on the supply voltage.
Table 1 – Pulse voltages
Pulse voltage
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
Number of voltage
pulses
3
NOTE
Peak value
V
Pulse width
at half-peak
ms
Equal to design voltage
10
Period between each
pulse
s
2
A suitable measuring circuit is shown in figure G.2 of IEC 61347-1.
15 Abnormal conditions
Ballasts shall not impair safety when operated under abnormal conditions at the maximum
value of their rated voltage range.
Compliance is checked by the tests of 15.1 to 15.3.
15.1 Removal of lamp(s)
During operation of the ballast at the maximum value of its rated voltage range and in
association with an appropriate lamp(s), the lamp(s) shall be disconnected for 1 h from the
ballast without switching off the supply voltage.
15.2 Lamp fails to start (cathodes intact electrically)
With a resistor in place of each lamp cathode, the ballast shall be operated at the maximum
value of its rated voltage range for 1 h.
The resistor value to be used shall be derived from the value of the nominal running current of
the lamp prescribed in the relevant lamp data sheet of IEC 60081 and IEC 60901 and
substituted in the following equation:
R=
11,0
W
2,1´ I n
where
ln
is the nominal running current of the lamp.
For lamps not covered by IEC 60081 and IEC 60901, the values declared by the lamp
manufacturer shall be used.
ã BSI 05-2001
Page 8
EN 61347−2−4:2001
15.3 Polarity reversal
When a ballast is declared to be proof against supply voltage polarity reversal it shall be
operated with reverse voltage for 1 h, at the maximum value of its rated voltage range with an
appropriate lamp(s).
At the end of the tests specified in 15.1, 15.2 and 15.3, the ballast shall show
–
that no live parts have become accessible;
–
that no breakdown of insulation to earth or accessible parts has occurred;
–
that the case temperature is below 200 °C.
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
To check that no live parts have become accessible, a test in accordance with clause 10 of
IEC 61347-1 shall be made.
To check the insulation, the electric strength test in accordance with clause 12 of IEC 61347-1
is repeated, but with the test voltage reduced to 75 % of the specified values.
To check whether the case temperature does not exceed 200 °C, the ballast shall be supported
by two wooden blocks 75 mm high, 10 mm thick and of a width equal to, or greater than, the
width of the ballast. The blocks shall be positioned with the extreme end of the ballast aligned
with the outer vertical sides of the blocks.
16 Fault conditions
The requirements of clause 14 of IEC 61347-1 apply.
17 Construction
The requirements of clause 15 of IEC 61347-1 are not applicable.
18 Creepage distances and clearances
The requirements of clause 16 of IEC 61347-1 apply.
19 Screws, current-carrying parts and connections
The requirements of clause 17 of IEC 61347-1 apply.
20 Resistance to heat, fire and tracking
The requirements of clause 18 of IEC 61347-1 apply, with the exception of the requirements for
tracking.
21 Resistance to corrosion
The requirements of clause 19 of IEC 61347-1 are not applicable.
ã BSI 05-2001
Page 9
EN 61347−2−4:2001
Annex A
(normative)
Test to establish whether a conductive part is a live part which
may cause an electric shock
The requirements of annex A of IEC 61347-1 apply.
Annex B
(normative)
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
Particular requirements for thermally protected lamp controlgear
The requirements of annex B of IEC 61347-1 are not applicable.
Annex C
(normative)
Particular requirements for electronic lamp controlgear with means
of protection against overheating
The requirements of annex C of IEC 61347-1 are not applicable.
Annex D
(normative)
Requirements for carrying out the heating tests of thermally protected
lamp controlgear
The requirements of annex D of IEC 61347-1 are not applicable.
Annex E
(normative)
Use of constant S other than 4 500 in tw tests
The requirements of annex E of IEC 61347-1 are not applicable.
ã BSI 05-2001
Page 10
EN 61347−2−4:2001
Annex F
(normative)
Draught-proof enclosure
The requirements of annex F of IEC 61347-1 are not applicable.
Annex G
(normative)
Explanation of the derivation of the values of pulse voltages
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
The requirements of annex G of IEC 61347-1 apply.
Annex H
(normative)
Tests
The requirements of annex H of IEC 61347-1 apply.
–––––––––––
ã BSI 05-2001
Page 11
EN 61347−2−4:2001
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions of
any of these publications apply to this European Standard only when incorporated in it by
amendment or revision. For undated references the latest edition of the publication referred to
applies (including amendments).
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication
Year
Title
EN/HD
Year
IEC 61347-1
2000
Lamp controlgear
Part 1: General and safety requirements
EN 61347-1
2001
IEC 60925
1)
D.C. supplied electronic ballasts for
tubular fluorescent lamps - Performance
requirements
EN 60925
1991
1)
2)
undated reference.
valid edition at date of issue.
2)
BS EN
61347-2-4:2001
IEC
61347-2-4:2000
BSI — British Standards Institution
BSI is the independent national body responsible for preparing
British Standards. It presents the UK view on standards in Europe and at the
international level. It is incorporated by Royal Charter.
Revisions
British Standards are updated by amendment or revision. Users of
British Standards should make sure that they possess the latest amendments or
editions.
It is the constant aim of BSI to improve the quality of our products and services.
We would be grateful if anyone finding an inaccuracy or ambiguity while using
this British Standard would inform the Secretary of the technical committee
responsible, the identity of which can be found on the inside front cover.
Tel: 020 8996 9000. Fax: 020 8996 7400.
Licensed Copy: HKPOLYU Library, HK Polytechnic Univ, 10 March 2003, Uncontrolled Copy, (c) BSI
BSI offers members an individual updating service called PLUS which ensures
that subscribers automatically receive the latest editions of standards.
Buying standards
Orders for all BSI, international and foreign standards publications should be
addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001.
Standards are also available from the BSI website at .
In response to orders for international standards, it is BSI policy to supply the
BSI implementation of those that have been published as British Standards,
unless otherwise requested.
Information on standards
BSI provides a wide range of information on national, European and
international standards through its Library and its Technical Help to Exporters
Service. Various BSI electronic information services are also available which give
details on all its products and services. Contact the Information Centre.
Tel: 020 8996 7111. Fax: 020 8996 7048.
Subscribing members of BSI are kept up to date with standards developments
and receive substantial discounts on the purchase price of standards. For details
of these and other benefits contact Membership Administration.
Tel: 020 8996 7002. Fax: 020 8996 7001. Further information about BSI is
available on the BSI website at .
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies. Except as
permitted under the Copyright, Designs and Patents Act 1988 no extract may be
reproduced, stored in a retrieval system or transmitted in any form or by any
means – electronic, photocopying, recording or otherwise – without prior written
permission from BSI.
This does not preclude the free use, in the course of implementing the standard,
of necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any other purpose than implementation then the prior
written permission of BSI must be obtained.
BSI
389 Chiswick High Road
London
W4 4AL
If permission is granted, the terms may include royalty payments or a licensing
agreement. Details and advice can be obtained from the Copyright Manager.
Tel: 020 8996 7070.