440
 HUMAN MACHINE INTERFACES
Bus connection board
•A9GT-(Q)BUSS/A9GT-(Q)BUS2S
Bus connection unit
•A9GT-BUSSU/A9GT-BUS2SU
MELSECNET/10 network connection unit

A7GT-J71LP23 (optical fiber)/A7GT-J71BR13 (coaxial)
MELSECNET (II) data link connection unit

A7GT-J71AP23 (optical fiber)/A7GT-J71AR23 (coaxial)
MELSECNET/B data link connection unit
•A7GT-J71AT23B (twisted pair)
CC-Link connection unit
•A8GT-J61BT13 (intelligent device station)/
A8GT-J61BT15 (remote device station)
RS-422 serial communication board
•A9GT-RS4
RS-232C serial communication board
•A9GT-RS2
RS-422 serial communication board
•A9GT-RS4
RS-232C serial communication board
•A9GT-RS2
RS-422 serial communication board (no clock function)
•A9GT-RS4
RS-232C serial communication board
•A9GT-RS2T (clock function)
•A9GT-RS2 (no clock function)
Required Communication Unit on the GOT Side Connection Cable Connection Type


Bus Connection
Network Connection
CPU Direct Connection
Computer Link Connection
Microcomputer
Connection, etc.
A956(W)GOT
A956WGOT
Bus Connection
Network Connection
CPU Direct Connection
Computer Link Connection
Microcomputer
Connection, etc.
MELSECNET/10
MELSECNET(II)
MELSECNET/B
CC-Link
RS-422
RS-232C
RS-232C
RS-422
RS-422
RS-232C
RS-422
RS-232C
Bus connection unit
•A9GT-BUS2SU/A9GT-50WQBUSS

A7GT-BUSS/A7GT-BUS2S (Hardware version B or later)


A9GT-BUSSU/A9GT-BUS2SU/A9GT-50WBUSS
MELSECNET/10 network connection unit

A7GT-J71LP23 (optical fiber)/A7GT-J71BR13 (coaxial)
MELSECNET (II) data link connection unit

A7GT-J71AP23 (optical fiber)/A7GT-J71AR23 (coaxial)
MELSECNET/B data link connection unit
•A7GT-J71AT23B (twisted pair)
CC-Link connection unit

A8GT-J61BT13 (Intelligent device station)
/
A8GT-J61BT15 (Remote device station)
A9GT-50WRS4
A9GT-50WRS4
A9GT-50WRS2
A9GT-50WRS4
A9GT-50WRS2
Required Communication Unit on the GOT Side Connection Cable
Connection Configuration
Bus Connection
Unit
Network Connection
Bus Connection
MELSECNET/10
MELSECNET(II)
MELSECNET/B
CC-Link

RS-422
RS-422
RS-422
RS-232C
RS-422
RS-232C
(A985(V), A975, A970, A960)
Large size
Medium size
(A950, A951(Q), A953, A956(W))
Computer
Link Connection
Microcomputer
connection, etc.
CPU Direct
Connection
Network Connection
Computer
Link Connection
Microcomputer
connection, etc.
CPU Direct
Connection
For cable model names, see the next page.
*
*
*
*
*
*

*
*
RS232C
RS422
*For A956W only
*See page 447 for information in this cable.
Mitsubishi Electric Automation | Human Machine Interfaces 441
• QnA/A Series
• Q Series (Q Mode)
• Motion controller
• Q Series (Q/A Mode)
• QnA/A Series
• QnA/A Series
• FX
1/FX2/FX2C Series
• FX Series (FX
0/FX0S/FX0N Series)
• FX Series
(FX1S/FX1N/FX2N/FX2NC Series)
• Q Series (Q/A Mode)
• Other manufacturer's PLC
• QnA Series serial communication unit
• Q Series serial communication unit
• A Series computer link unit
• Other manufacturer's PLC
• QnA Series serial communication unit
• A Series computer link unit
• Other manufacturer's PLC
• PLC
• Microcomputer board

• Personal computer
Touch switches, like pushbuttons,
can make a quick response.
Several GOTs can be used as
remote control terminals.
Several GOTs can be connected
inexpensively and quickly.
Can be connected with MELSEC-Q
/QnA/A/FX Series at the lowest cost.
Several GOTs can be connected
easily through serial communication
(it is connected with a computer link
unit one by one).
Can be connected freely with
microcomputer boards or personal
computers.
• Q connection: 5 units
• QnA/A connection: 3 units
• Bus type: 31 units
• Loop type: 63 units
• Loop type: 64 units
• 32 units
• Remote device station: 32 units
• Intelligent device station: 26 units
• 1 unit
• 2 units

(when function extension board is used)
• 1 unit
• 1 unit

• 1 unit
• 1 unit

Q connection : 37m

QnA/A (large) connection : 36.6m

QnAS/AnS (small) connection : 35m

500 m (Coaxial, 500m between stations: 5C-2V cable)

30 km (Optical, 1 km between stations: QSI cable)

10 km (Coaxial, 500m between stations: C-2V cable)

10 km (Optical, 1 km between stations: SI cable)
200 m
(125 kbps, 1200 m: shielded twisted pair cable)
1200 m
(156 kbps: shielded twisted pair cable)
• 30m
• 31.5m
• 3m
• Per each connection specification
• 30m
• Q Series : 1200m, A Series : 200m
• 15m
• Per each connection specification
Connected To: Feature
Maximum No. of GOTs Connected

Maximum Connection Distance
• Q Series (Q Mode)
• QnA/A Series
• Q Series (Q/A Mode)
• QnA/A Series
• QnA/A Series
• FX
1/FX2/FX2C Series
• FX Series (FX
0/FX0S/FX0N Series)
• FX Series

(FX1S/FX1N/FX2N/FX2NC Series)
• Q Series serial communication unit
• A Series computer link unit
• Other manufacturer's PLC
• QnA Series serial communication unit
•PLC
• Microcomputer board
• Personal computer
Touch switches, like pushbuttons,
can make a quick response.
Several GOTs can be used as
remote control terminals.
Several GOTs can be connected
inexpensively and quickly.
Can be connected with MELSEC-
QnA/A/FX Series at the lowest cost.
Several GOTs can be connected
easily through serial communication

(it is connected with a computer link
unit one by one).
Can be connected freely with
microcomputer boards or personal
computers.
• Q connection: 5 units
• QnA/A connection: 3 units
• Bus type: 31 units
• Loop type: 63 units
• Loop type: 64 units
• 32 units
• Remote device station: 32 units
• Intelligent device station: 26 units
• 1 unit
• 2 units
(when function extension board is used)
• Per each CPU specification
• 1 unit
• Q connection : 37m
• QnA/A (large) connection : 36.6m
• QnAS/AnS (small) connection : 36m

500 m (Coaxial, 500m between stations: 5C-2V cable)

30 km (Optical, 1 km between stations: QSI cable)

10 km (Coaxial, 500m between stations: C-2V cable)

10 km (Optical, 1 km between stations: SI cable)
200 m

(125 kbps, 1200 m: shielded twisted pair cable)
1200 m
(156 kbps: shielded twisted pair cable)
• 30m
• 31.5m
• Q Series : 1200m, A Series : 200m
• 30m
• Per each connection specification
Connected To: Feature
Maximum No. of GOTs Connected
Maximum Connection Distance
For more information, see bus connection system configuration
For more information, see bus connection system configuration
For more information, see bus connection system configuration
For more information, see bus connection system configuration
For more information, see bus connection system configuration
For more information, see bus connection
system configuration
For more information, see bus connection system configuration
For more information, see bus connection system configuration
442
 HUMAN MACHINE INTERFACES
A950
GOT
A951
GOT-Q
A951
GOT
A953
GOT

Built-in RS-422 interface

Built-in bus interface
Built-in RS-232C interface
Communication Unit on the GOT Side
GOT
Model
Connection Cable Connection Configuration
Bus connection
RS-422
RS-422
RS-422
RS-422
RS-422
RS-232C
RS-232C
RS-232C
0.7



0.6


0.6
1.2


1.2
1.2

1.2

1.2
3.0


3.0
3.0
3.0

3.0
5.0


5.0
5.0
5.0

5.0

10.0
10.0




10.0

20.0
20.0




20.0


30.0
30.0



30.0







35.0

Cable Product Name Model Name Length (m)
Reference
External View
Computer
link connection
Computer link
connection
Microcomputer
connection

Microcomputer
connection
CPU direct
connection
CPU direct
connection
(A950, A951(Q), A953, A956(W))
Bus
connection
Computer
Link Connection
Computer Link
Connection
Microcomputer
Connection
Microcomputer
Connection
CPU Direct
Connection
CPU Direct
Connection
RS232C
RS422
Per specification
Per each specification
Per specification
Per specification
Per specification
Per specification
Per specification

A1SC B
A8GT-C BS
A8GT-C EXSS
A8GT-C NB
AC B
AC B-R
A9GT-QC BS
QC B
3.0 10.0 30.0
Optical fiber cable
Coaxial cable
Shielded twisted pair cable
Shielded 3-wire twisted pair cable
RS-422 cable
RS-232C cable
RS-422 cable
RS-232C cable
RS-422 cable
RS-232C cable
AC R4-25P
FX9GT-CAB0(- (M))
AC R4-25P + FX-422AW0
QC30R2
Supplied by user*
AC R4-25P
Supplied by user*
Supplied by user*
Supplied by user*
Supplied by user*
Bus connection

cable
1.5
3.0
3.0
3.0
10.0
10.0
30.0
Connection Cable List (Large-Size GOT)
3.0 + 1.5 10.0 + 1.5 30.0 + 1.5
Optical
fiber cable
Shielded
twisted
pair cable
Medium size
*For user-made cables, refer to the GOT-A900 Series Users Manual (Connection).
Mitsubishi Electric Automation | Human Machine Interfaces 443
Others
• QnA/A Series
• FX
1/FX2/FX2C Series
• FX Series(FX
0/FX0S/FX0N Series)
• FX Series(FX
1S/FX1N/FX2N/FX2NC Series)
• Q Series serial communication unit
• A Series computer link unit
• Other manufacturer's PLC
• QnA Series serial communication unit

• PLC
• Microcomputer board
• Personal computer
• Q Series (Q Mode)
• QnA/A Series
• Q Series (Q/A Mode)
• Q Series serial communication unit
• QnA Series serial communication unit
• Other manufacturer's PLC
• A Series computer link unit
• PLC
• Microcomputer board
• Personal computer
Can be connected with MELSEC-
QnA/A/FX Series at the lowest cost.
Several GOTs can be connected
easily through serial communication
(it is connected with a computer link
unit one by one).
Can be connected freely with
microcomputer boards or personal
computers.
Touch switches, like pushbuttons,
can make a quick response.
Can be connected with MELSEC-Q
Series at the lowest cost.
Several GOTs can be connected
easily through serial communication
(it is connected with a computer link
unit one by one).

Can be connected freely with
microcomputer boards or personal
computers.
• 1 unit
• 2 units

(when function extension board is used)
• Per each CPU specification
• 1 unit
• Q connection: 5 units
• QnA/A connection: 3 units
• 1 unit
• Per each CPU specification
• 1 unit
• 30m
• 31.5m
• Q Series : 1200m, A Series : 200m
• 30m
• Per each connection specification

Q connection : 37m • QnA/A (large) connection : 36.5m
•QnAS/AnS (small) connection : 36m
• Q Series : 3m
• 15m
• Per each connection specification
Connected To: Feature
Maximum No. of GOTs Connected
Maximum Connection Distance
For more information, see bus connection system configuration For more information, see bus connection system configuration


0.6
0.7



0.6


1.2
1.2


1.2
1.2
1.2

3.0
3.0


3.0
3.0
3.0

5.0
5.0


5.0
5.0

5.0

10.0

10.0
10.0



20.0


20.0
20.0



30.0


30.0
30.0



35.0








Per specification
Per specification
Per specification
Per specification
Per specification
A9GT-QC BS
QC B
A1SC B
A8GT-C BS
A8GT-C EXSS
A8GT-C NB
AC B
AC B-R
3.0 10.0 30.0
Optical fiber cable
Coaxial cable
Shielded twisted pair cable
Shielded 3-wire twisted pair cable
RS-422 cable
RS-232C cable
RS-422 cable
RS-422C cable
AC R4-25P
FX9GT-CABO(- (M))
AC R4-25P + FX-422AWO
QC30R2
Supplied by user*

AC R4-25P
Supplied by user*
Supplied by user*
Bus connection
cable
1.5

3.0
3.0

3.0
10.0
10.0

30.0
Connection Cable List (Medium-Size GOT)
Cable Product Name Model Name Length (m)
Reference
External View
*
For user-made cables, refer to the GOT-A900 Series Users Manual (Connection).
Optical
fiber cable
Shielded
twisted
pair cable
444
 HUMAN MACHINE INTERFACES
3 6 6
Item Illustration

Number
Component Equipment (Unit Model Name)
A985GOT(-V)/A97 GOT/A960GOT + A9GT-QBUSS/A9GT-QBUS2S
A956GOT + A9GT-QBUS2SU, A956WGOT + A9GT-50WQBUSS
A951GOT-Q
A985GOT(-V)/A97 GOT/A960GOT + A9GT-QBUS2S
A956GOT + A9GT-QBUS2SU, A956WGOT + A9GT-QBUS2SU
QC06B(0.6m)/QC12B(1.2m)/QC30B(3m)/QC50B(5m)/QC100B(10m)
A9GT-QC150BS(15m)/A9GT-QC200BS(20m)/A9GT-QC250BS(25m)/A9GT-QC300BS(30m)
A9GT-QC350BS(35m)
A9GT-QC150BS(15m)/A9GT-QC200BS(20m)/A9GT-QC250BS(25m)/A9GT-QC300BS(30m)
QC06B(0.6m)/QC12B(1.2m)/QC30B(3m)/QC50B(5m)/QC100B(10m)/
A9GT-QC150BS(15m)/A9GT-QC200BS(20m)/A9GT-QC250BS(25m)/A9GT-QC300BS(30m)
A9GT-QCNB
GOT
Connection Cable
Bus Extension
Connector Box
1 unit
Within 13.2m
13.2m or more
The first GOT is
within 13.2m.
The first GOT
is 13.2m or
more away.
Up to 13.2 m
Main base Extension base
2 to 5 units
Number of

Units Connected
Installation Distance
System Configuration
*
If the system configuration uses an A9GT-QCNB, the same number of steps as the GOT main unit must be set for the A9GT-QCNB.
For setting the number of steps, refer to the following notes:
*
If an expansion base unit is used, the extension cab
le length (between the base units) is included.
Note: If the QCPU (Q Mode) is connected through a bus, one expansion stage (16 points x 10 slots) is occupied for GOT connection. The GOT is assigned to the I/O slot of the expansion step.
1
2
3
4
5
6
7
*
*
Up to 13.2m
*
Up to 37m
Up to 37m
5 6 6
Up to 37m
*
The last one
1
2nd to 4th
units

2
1st to 4th
units
The last one
2nd to 4th
units
1st to 4th
units
2
122
3
4
7
7
1st unit
1
1st unit
1
1. When the QCPU (Q Mode) is connected
PULL
USB
Q25HCPU QX10 QJ71BR11
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR

RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
QX41
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
MODE
RUN
ERR
USER
BAT

BOOT
PULL
QJ71BR11QX41
POWER
Q61P-A1
PULL
QX10 QJ71BR11
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
QX41
0
1
2
3
4
5

6
7
8
9
A
B
C
D
E
F
QJ71BR11QX41
POWER
Q61P-A1
QX10
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F

PULL
USB
Q25HCPU QX10 QJ71BR11
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
QX41
0
1
2
3
4
5
6
7
8
9

A
B
C
D
E
F
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41
POWER
Q61P-A1
PULL
USB
Q25HCPU QX10 QJ71BR11
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
RUN
T.PASS
SD

ERR
MNG
D.LINK
RD
ERR
QX41
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41

POWER
Q61P-A1
PULL
USB
Q25HCPU QX10 QJ71BR11
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
QX41
0
1
2
3
4
5
6
7

8
9
A
B
C
D
E
F
MODE
RUN
ERR
USER
BAT
BOOT
PULL
QJ71BR11QX41
POWER
Q61P-A1
PULL
QX10 QJ71BR11
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
RUN
T.PASS

SD
ERR
MNG
D.LINK
RD
ERR
QX41
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
QJ71BR11QX41
POWER
Q61P-A1
QX10
0
1
2

3
4
5
6
7
8
9
A
B
C
D
E
F
PULL
QX10 QJ71BR11
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD

ERR
QX41
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
QJ71BR11QX41
POWER
Q61P-A1
QX10
0
1
2
3
4
5
6
7

8
9
A
B
C
D
E
F
PULL
QX10 QJ71BR11
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
RUN
T.PASS
SD
ERR
MNG
D.LINK
RD
ERR
QX41
0
1
2

3
4
5
6
7
8
9
A
B
C
D
E
F
QJ71BR11QX41
POWER
Q61P-A1
QX10
0
1
2
3
4
5
6
7
8
9
A
B
C

D
E
F
Bus Connection
The Bus connection is one of the more popular connection methods available for AGOT as it provides fast communications to rack based
controllers. As a result, users need to consider the following when configuring a system connected to the BUS:
A. Connected Controller
1. QBUS
2. QnA/AnA (large type)
3. QnAs/AnAs (small type)
4. A0J2H Controllers
5. Motion Controller (large type)
6 Motion Controller (small type)
B. Proximity of first connected GOT terminal
1. Within [x] meters, x value depends on controller
2. More than [x] meters, x value depends on controller
C. How many GOT Units are to be connected
1. Up to 5 GOTs can be connected together from a single BUS connection
Mitsubishi Electric Automation | Human Machine Interfaces 445
Main base Extension base
Number of
Units Connected
Installation Distance
System Configuration
3 6
Item Illustration
Number
Component Equipment (Unit Model Name)
A985GOT(-V)/A97 GOT/A960GOT + A9GT-BUSS/A9GT-BUS2S/A9GT-BUSSU/A9GT-BUS2SU
A956GOT + A

9GT-BUSSU/A9GT-BUS2SU/A7GT-BUSS/A7GT-BUS2S, A956WGOT + A9GT-50WBUSS
A951GOT
A985GOT(
-V)
/A97

GOT/A960GOT
+ A9GT-BUS2S/A9GT-BUS2SU
A956GOT +
A9GT-BUS2SU/A7GT-BUS2S, A956WGOT + A9GT-BUS2SU
A8GT-C12NB(1.2m)/A8GT-C30NB(3m)/A8GT-C50NB(5m)
A8GT-C100EXSS(10m)/A8GT-C200EXSS(20m)/A8GT-C300EXSS(30m)
AC06B(0.6m)/AC12B(1.2m)/AC12B-R(1.2m)/AC30B(3m)/AC30B-R(3m)/AC50B(5m)/AC50B-R(5m)
A1SC07B(0.7m)/A1SC12B(1.2m)/A1SC30B(3m)/A1SC50B(5m)/A8GT-C100BS(10m)/
A8GT-C200BS(20m)/A8GT-C300BS(30m)
A7GT-CNB
GOT
Connection Cable
Bus Extension
Connector Box
1 unit
Within 6.6m
6.6m or more
The first GOT
is within 6.6m
The first GOT
is 6.6m or
more away
Up to 6.6m
2 unit

3 unit
*
When a bus connection cable (A8GT-C100EXSS, A8GT-C200EXSS, or A8GT-C300EXSS) is used, connect the cable connectors as follows:
Connector "COM1" PLC CPU side
Connector "COM2" GOT side
*
If an expansion base unit is used, the extension cable length (between base units) is included.
1
2
3
4
5
6
7
*
*
Up to 6.6m
*
5 4 6
Up to 6.6m Up to 30m
*
2nd unit
1
1st unit
2
5 4
Up to 6.6m Up to 30m
Up to 30m
*
1st unit

1
2nd unit
1
1st unit
2
3
The first GOT
is within 6.6m
3 6 6
Up to 6.6m
*
Up to 30m
3rd unit
1
2nd unit
2
1st unit
2
1st unit
1
2. When QnACPU (large type) or ACPU (large type) is connected
7
7
A
X10
A
4
U
CPU
A

62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A

J71BR11
A
J71BR11
A
X10
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
62P
A
X10
A
X10
A

X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A

62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
4
U
CPU
A
62P
A
X10
A
X10
A
X10
A

Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
4
U
CPU
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A

X10
A
4
U
CPU
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
4
U
CPU
A
62P
A

X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
446
 HUMAN MACHINE INTERFACES
1
2
3
4
5
6
7
*
Bus Connection
3. When QnASCPU (small type) or AnSCPU (small type) is connected
A985GOT(-V)/A97*GOT/A960GOT + A9GT-BUSS/A9GT-BUS2S/A9GT-BUSSU/A9GT-BUS2SU
A956GOT
+
A9GT-BUSSU/A9GT-BUS2SU/A7GT-BUSS/A7GT-BUS2S,
A956WGOT

+
A9GT-50W BUSS
A951GOT
A985GOT(
-V)
/A97*GOT/A960GOT
+
A9GT-BUS2S/A9GT-BUS2SU
A956GOT
+
A9GT-BUS2SU/A7GT-BUS2S
A956WGOT
+
A9GT-BUS2SU
A1SC07B(0.7m)/A1SC12B(1.2m)/A1SC30B(3m)/A1SC50B(5m)
A8GT-C100EXSS(10m)/A8GT-C200EXSS(20m)/A8GT-C300EXSS(30m)
A1SC05NB(0.5m)/A1SC07NB(0.7m)/A1SC30NB(3m)/A1SC50NB(5m)
A1SC07B(0.7m)/A1SC12B(1.2m)/A1SC30B(3m)/A1SC50B(5m)/
A8GT-C100BS(10m)/A8GT-C200BS(20m)/A8GT-C300BS(30m)
A7GT-CNB
*
The system configuration has the following components.
Connector "COM1" PLC CPU side
Connector "COM2" GOT side
*
If an expansion base unit is used, the extension cable length (between the base units) is included.
Item Illustration
Number
Component Equipment (Unit Model Name)
GOT

Connection Cable
Bus Extension
Connector Box
7
5
4
Up to 30m
Up to 6m
Up to 6m
1st unit
1
1 unit
Within 6m
6m or more
The first GOT
is within 6m.
The first GOT
is 6m or
more away.
2 unit
3 unit
The first GOT
is within 6m
3 6 6
Up to 6m
Up to 30m
3rd unit
1
2nd unit
2

1st unit
2
3 6
Up to 30m
2nd unit
1
1st unit
2
4 6
Up to 30m
2nd unit
1
1st unit
4
Up to 30mUp to 6m
Up to 6m
1st unit
1
*
*
*
*
A
1SP60
A
1S62P
A
1SP60
A
1SP60

A
1SH42
A
1SH42
A
2
U
SCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
A
1SP60
A
1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
1SH42
POWER

3
Up to 6m
1st unit
1
A
1SP60
A
1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
2
U
SCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
A
1SP60
A

1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
1SH42
POWER
A
1SP60
A
1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
1SH42
POWER
A
1SP60
A

1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
1SH42
POWER
A
1SP60
A
1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
1SH42
POWER
A
1SP60
A

1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
1SH42
POWER
A
1SP60
A
1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
2
U
SCPU
RUNPOWER
ERROR

L.CLR
RESET
RUN
STOP
RESET
A
1SP60
A
1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
2
U
SCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
A
1SP60

A
1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
2
U
SCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
A
1SP60
A
1S62P
A
1SP60
A
1SP60
A

1SH42
A
1SH42
A
2
U
SCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
2
Number of
Units Connected
Installation Distance
System Configuration
Main baseExtension base
Mitsubishi Electric Automation | Human Machine Interfaces 447
A985GOT(-V)/A97*GOT/A960GOT + A9GT-BUSS/A9GT-BUS2S / A9GT-BUSSU/A9GT-BUS2SU
A956GOT + A9GT-BUSSU/A9GT-BUS2SU/A7GT-BUSS/A7GT-BUS2S, A956WGOT + A9GT-50W BUSS
A951GOT
A9GT-J2C10B (1m)
A0J2HCPU
A0J2C
A0J2-PW
GOT
Connection Cable

CPU
I/O Cable
Power Supply Unit
1 unit
Up to 1m
Number of Units Connected
System Configuration
1
2
3
4
5
24
3 5
1st unit
1
4. When the A0J2HCPU is used
5. When motion controller A273UCPU, A273UHCPU, A273UHCPU-S3, or A373UCPU(-S3) is connected
A985GOT(-V)/A97*GOT/A960GOT + A9GT-BUSS/A9GT-BUS2S / A9GT-BUSSU/A9GT-BUS2SU
A956GOT + A9GT-BUSSU/A9GT-BUS2SU/A7GT-BUSS/A7GT-BUS2S, A956WGOT + A9GT-50WBUSS
A951GOT
A985GOT
(
-V
)
/A97*GOT/A960GOT + A9GT-BUS2S/A9GT-BUS2SU
A956
(
W
)

GOT + A9GT-BUS2SU/A7GT-BUS2S
A370C12B-S1(1.2m)/A370C25B-S1(2.5m)
A370C12B(1.2m)/A370C25B(2.5m)
AC06B(0.6m)/AC12B(1.2m)/AC12B-R(1.2m)/AC30B(3m)/AC30B-R(3m)/AC50B(5m)/AC50B-R(5m)
A8GT-C100EXSS(10m)/A8GT-C200EXSS(20m)/A8GT-C300EXSS(30m)
A1SC07B(0.7m)/A1SC12B(1.2m)/A1SC30B(3m)/A1SC50B(5m)/A8GT-C100BS(10m)/
A8GT-C200BS(20m)/A8GT-C300BS(30m)
A8GT-C12NB(1.2m)/A8GT-C30NB(3m)/A8GT-C50NB(5m)
A7GT-CNB
GOT
Connection Cable
Bus Extension
Connector Box
Notes:
1. Connect the cable to the PLC expansion connector.
2. If a bus connection cable (A8GT-C100EXSS, A8GT-C200EXSS, or A8GT-C300EXSS) is used, connect as follows:
Connector "COM1" PLC CPU side
Connector "COM2" GOT side
1
2
3
4
5
6
7
8
9
*1
*1
*2

Item Illustration
Number
Component Equipment (Unit Model Name)
Item Illustration
Number
Component Equipment (Unit Model Name)
448
 HUMAN MACHINE INTERFACES
Bus Connection
*If an expansion base unit is used, the extension cable length (between base units) is included.
1 unit
Within 2.5m
2.5m or more
The first GOT
is within 2.5m
The first GOT
is 2.5m or
more away
The first GOT
is within 2.5m
Up to 2.5m
2 unit
3 unit
3
1st unit
1
4 6
7
Up to 2.5m Up to 30m
2nd unit

1
1st unit
2
9
3 6
7
Up to 2.5m Up to 30m
3rd unit
1
2nd unit
2
1st unit
2
4 6
Up to 2.5m Up to 30m
Up to 2.5m Up to 30m
1st unit
1
9
3
7
2nd unit
1
1st unit
2
A
X10
A
4
U

CPU
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
4
U
CPU
A
62P
A
X10
A
X10
A

X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
4
U
CPU
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A

J71BR11
A
X10
A
4
U
CPU
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
4
U
CPU
A

62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
Number of
Units Connected
Installation Distance
System Configuration
1 unit
Within 6.6m
6.6m or more
The first GOT
is within 6.6m
The first GOT
is 6.6m or
more away
The first GOT
is within 6.6m
2 unit

3 unit
4 8 6
7
Up to 6.6m Up to 30m
3rd unit
1
2nd unit
2
1st unit
2
9
4 5 6
7
Up to 6.6m Up to 30m
2nd unit
1
1st unit
2
9
4 5 6
Up to 6.6m Up to 30m
Up to 30m
1st unit
1
4 8
7
Up to 6.6m
2nd unit
1
1st unit

2
4
8
Up to 6.6 m
1st unit
1
*
*
*
A
X10
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A

62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A

J71BR11
A
J71BR11
A
X10
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
62P
A
X10
A
X10
A

X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
Number of
Units Connected
Installation Distance

System Configuration
Main base Extension base
A
X10
A
4
U
CPU
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
4
U
CPU

A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
4
U
CPU
A
62P
A
X10
A
X10
A
X10

A
Y11
A
Y11
A
J71BR11
A
J71BR11
A
X10
A
4
U
CPU
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11

A
X10
A
4
U
CPU
A
62P
A
X10
A
X10
A
X10
A
Y11
A
Y11
A
J71BR11
A
J71BR11
*
*
5A. When the A273UCPU, A273UHCPU, A273UHCPU-S3, or A373UCPU(-S3) is connected
(When expansion base is NOT used.)
5B. When the A273UCPU, A273UHCPU, A273UHCPU-S3, or A373UCPU(-S3) is connected
(When expansion base A65B/A68B is used to connect with the GOT.)
Mitsubishi Electric Automation | Human Machine Interfaces 449
A

1SP60
A
1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
2
U
SCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
3
5
1 unit
2 unit
Up to 30mUp to 3m
*If an expansion base unit is used, the extension cable length (between base units) is included.
Notes:
1. The special function unit with the following model is shown.

AJ71QC24(R2/R4)
2. The special function unit with the following model is shown.

AD51(S3), AD51H(S3), AD51FD(S3), AD57G(S3), AJ71C21(S1), AJ71C22(S1), AJ71C23, AJ71C24(S3/S6/S8), AJ71E71(-S3),
AJ71UC24, A1SJ71C24(-R2/PRF/R4), A1SJ71UC24(-R2/PRF/R4), A1SJ71E71-B2/B5(-S3), AJ61BT11
,
A1SJ61BT11
Up to 3m Up to 30m
*
2nd unit
1
1st unit
2
4
1st unit
1
6. When A171SCPU-S3, A171SHCPU, A172SHCPU, or A173UHCPU is connected.
(Use PLC expansion base unit A168B to connect with the GOT.)
Notes for Bus Connection
Bus connection provides the fastest transfer speed among GOT connection forms. The Q Series (Q Mode) allows up to 5 GOTs to be connected with a PLC, and the QnA/A Series, up
to 3 GOTs to be connected with a PLC. The Q Series (Q Mode) allows GOTs to be installed up to 37m away, and the QnA/A Series, up to 36.6m (35m for small units). Bus connection
provides high-speed transmission without using a computer link unit.
• When it is connected to a bus, the GOT is regarded as a 32-point special function unit.
• The GOT is assigned to a free I/O slot in the expansion base unit.

The following free I/O slots are required according to the number of GOTs to be connected.

1 unit: 1 slot 2 units: 2 slots 3 units: 3 slots
• If the above free I/O slots are unavailable, but the following free points are
available, GOTs can be used.

1 unit: 32 points 2 units: 64 points 3 units: 96 points
Q3ACPU, Q4A(R)CPU, A3 CPU, A4UCPU, and A0J2HCPU
require free I/O slots in the maximum expansion step range. The A17 CPU(S3) does not
have these restrictions.
GOT when viewed from the QnA/A series CPU
Restriction on the number of GOTs that can be connected
• The number of GOTs that can be connected depends on the PLC CPU and the number of special function units to be installed.

When it is connected to a bus, the GOT is regarded as a 16-point intelligent function unit.
• Only the Q Series CPU (Q Mode) can be connected through a bus.
The Q Series (A Mode) cannot be connected through a bus.
• Up to 5 units can be connected.

One expansion step is occupied when a GOT is connected.
Therefore, the expansion base cannot be set to the same step count
as the GOT.
When the second to fifth GOTs are connected, the expansion step
count does not increase. The same number as the first GOT is set to
the GOT expansion step count.
GOT when viewed from the Q Series CPU
Number of GOTs that can be connected
GOT + number of special function units
to be installed
QnA(R), QnAS(H)CPU
Up to 3 units
No limit when GOT + special function units
as shown in *1
Up to 6 units when GOT special function units
as shown in *2
AnU, AnA, A2US, A2USHCPU

Up to 3 units
Up to 6 units when GOT special function units
as shown in *2
CPUs not shown on the left
Up to 2 units
Up to 2 units when GOT special function units
as shown in *2
Number of GOTs that can be connected
GOT + number of special function units
to be installed
A0J2HCPU
Up to 1 unit
Up to 2 units when GOT special function units
as shown in *2
Motion Controller (A273U, A273UH, A373UCPU(-S3))
Up to 3 units
Up to 6 units when GOT special function units
as shown in *2
Motion Controller (CPUs not shown on the left)
Up to 2 units
Up to 2 units when GOT special function units
as shown in *2
Item Illustration
Number
Component Equipment (Unit Model Name)
A985GOT(-V) / A97*GOT/A960GOT + A9GT-BUSS/A9GT-BUS2S /

A9GT-BUSSU/A9GT-BUS2SU
A956GOT + A9GT-BUSSU/A9GT-BUS2SU/A7GT-BUSS/A7GT-BUS2S, A956WGOT + A9GT-50WBUSS
A951GOT(-V)

A985GOT/A97*GOT/A960GOT
+
A9GT-BUS2S/A9GT-BUS2SU
A956WGOT
+
A9GT-BUS2SU/A7GT-BUS2S
A1SC01B (0.055m) / A1SC03B(0.33m) / A1SC07B (0.7m) / A1SC12B (1.2m ) / A1SC30B (3m)
A8GT-C100EXSS (10m) / A8GT-C200EXSS(20m) / A8GT-C300EXSS(30m)
A1SC07B (0.7m) / A1SC12B (1.2m) / A1SC30B (3m) / A1SC50B (5m) / A8GT-C100BS (10m) /
A8GT-C200BS (20m) / A8GT-C300BS (30m)
GOT
Connection Cable
2. Connect the connection cable to the PLC expansion connector.
1
2
3
4
5
*2
*1
Number of Units Connected
System Configuration
Extension baseMain base
Notes:
1. The system configuration has the following components.
Connector [COM1] motion CPU side Connector [COM2] GOT side
A
1SP60
A
1S62P

A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
1SH42
POWER
A
1SP60
A
1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
2
U
SCPU
RUNPOWER
ERROR
L.CLR

RESET
RUN
STOP
RESET
A
1SP60
A
1S62P
A
1SP60
A
1SP60
A
1SH42
A
1SH42
A
1SH42
POWER
Bus Connection

×