Series HMI Connection Manual
Hướng dẫn kết nối PLC với HMI Delta DOP
Keyence KV1000
HMI Factory Setting:
Baud rate: 9600. 8. Even. (RS232)
Controller Station Number: 0 (no PLC station number in protocol, one on one connection)
Control Area / Status Area: DM-0/DM-10
Connection
a. RS-232 (DOP-A/AE/AS, DOP-B Series)
DOP series
Controller
9 pin D-sub male (RS-232)
RXD (2)
(5) SD
TXD (3)
(3) RD
GND (5)
(4) SG
Definition of PLC Read/Write Address
a. Registers
Type
Format
Word No. (n)
Read/Write Range
Data
Length
Data Memory
DM-n
DM-0 ~ DM-65535
Word
Control Memory
CM-n
CM-0 ~ CM-11999
Word
Temporary Data Memory
TM-n
TM-0 ~ TM-511
Word
Extended Data Memory
EM-n
EM-0 ~ EM-65535
Word
Extended Data Memory
FM-n
FM-0 ~ FM-32767
Word
Address Register
Z-n
Z-1 ~ Z-12
Word
Digital Trimmer
AT-n
AT-0 ~ AT-7
Word
High-speed Counter
CTH-n
CTH-0 ~ CTH-1
Double
Note
Word
CTC Preset Value
PCTC-n
PCTC-0 ~ PCTC-3
Double
Word
Timer Preset Value
PT-n
PT-0 ~ PT-3999
Double
Word
Counter Preset Value
PC-n
PC-0 ~ PC-3999
Double
Word
V1.01
Revision May, 2011
www.plc.today 71
Series HMI Connection Manual
Type
High-speed Counter
Format
Word No. (n)
CTC-n
Data
Length
Read/Write Range
CTC-0 ~ CTC-3
Double
Comparator
Timer
Note
Word
T-n
T-0 ~ T-3999
Double
Word
Counter
C-n
C-0 ~ C-3999
Double
Word
b. Contacts
Format
Type
Word No. (n)
Bit No. (b)
Read/Write Range
Control Relay
CR-nbb
CR-000 ~ CR-3915
Internal Memory Relay
MR-nbb
MR-000 ~ MR-99915
Latch
LR-nbb
LR-000 ~ LR-99915
Relay
R-nbb
R-000 ~ R-59915
High-speed Counter
CTC-b
CTC-0 ~ CTC-3
Timer Contact
T-b
T-0 ~ T-3999
Counter Contact
C-b
C-0 ~ C-3999
Note
comparator
72
V1.01
Revision May, 2011
Series HMI Connection Manual
Hướng dẫn kết nối PLC với HMI Delta DOP
Keyence KV/KZ Series
HMI Factory Setting:
Baud rate: 9600, 8, Even, 1 (RS-232)
Controller Station Number: 0 (no PLC station number in protocol, one on one connection)
Control Area / Status Area: DM-0 / DM-10
Connection
a. RS-232 (DOP-A, DOP-B Series)
KV Series (Note1)
DOP series
Controller
9 pin D-SUB (RS-232)
RJ-11 (RS-232)
RXD (2)
(5) SD
TXD (3)
(3) RD
GND (5)
(4) SG
KZ Series (Note1)
DOP series
Controller
9 pin D-SUB (RS-232)
RJ-11 (RS-232)
RXD (2)
(5) SD
TXD (3)
(3) RD
GND (5)
(4) SG
Definition of PLC Read/Write Address
a. Registers
Type
Format
Word No. (n)
Read/Write Range
Data
Length
Timer
T-n
T-0 – T-199
Word
Counter
C-n
C-0 – C-199
Word
High-speed counter
CTH-n
CTH-0 – CTH-1
Word
High-speed counter
CTC-n
CTC-0 – CTC-3
Word
Note
comparator
V1.01
Revision August, 2010
www.plc.today 73
Series HMI Connection Manual
Type
Format
Data
Length
Read/Write Range
Word No. (n)
Data memory
DM-n
DM-0 – DM-1999
Word
Temporary data memory
TM-n
TM-0 – TM-31
Word
Timer preset value
PT-n
PT-0 – PT-199
Word
Counter preset value
PC-n
PC-0 – PC-199
Word
CTC preset value
PCTC-n
PCTC-0 – PCTC-3
Word
Note
b. Contacts
Format
Type
Read/Write Range
Word No. (n)
Bit No. (b)
Note
Relay
R-nbb
R-000 – R-6915
Timer
T-b
T-0 – T-199
1
Counter
C-b
C-0 – C-199
1
CTC-b
CTC-0 – CTC-3
High-speed counter
comparator
NOTE
1)
Please be aware the pin definition of SD, RD is reversed in KZ-80T and KV series.
This protocol regards PLC protocol in KV series, when communicates with KZ series PLC,
the following divergence will occur.
1. Readable Timer address is not continuous. For example:
T-0 ~ T-9 can be read
T10 cannot be read
T11 ~ T20 can be read
T21 ~ T50 cannot be read …etc.
2. Counter cannot be read. For example:
Registers: C-, CTH-, CTC-,PC-, PCTC- all cannot be read.
Contacts: C-, CTC- cannot be read as well.
74
V1.01
Revision August, 2010